Ipca Laboratories Limited

1 Pharma Zone, Sez Indore, Pithampur, Dhar, India

FEI 3007574780DUNS 677600550

Company: Ipca Laboratories Limited · Linked by exact D-U-N-S match (650387009) in FDA registration data

FDA has 4 inspections on file for Ipca Laboratories Limited in Dhar, India (FEI 3007574780), from 2012 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Oct 17, 2014. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Ipca Laboratories Limited (D-U-N-S 650387009), has registered 6 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2012–2023
1 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
2 of 4
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate OOS investigations

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. On 12/2/2022, the lab recorded OOS result PIT/OOS/2020/050 for dissolution test by UV-visible Spectrophotometer. The OOS result was reported for Batch No. (b) (4) (non-US market) (Unit result (b) (4) against the Specification NLT % (Q) of the labeled amount of In the Phase I of the investigation, no assignable root cause was identified. In Phase IIA manufacturing investigation no assignable root cause was identified. In Phase IIB investigation, you hypothesized improper (b) (4) as the probable root cause. You attempted to verify lower assay value from "improper (b) (4)" through a hypothesis test using a new sample solution that was obtained from an additional dissolution study for one single tablet. You obtained a higher value from (b) (4) (b) (4) sample solution %) but lower values from (b) (4) %). It is not clear why lower value obtained when the analyst followed the required test procedure STP No. TP/DR/0691/00 Dissolution (By UV) for (b) (4) Tablets, Effective date 10/25/2019, in line with your analytical method validation report, AMV/R/2017/009/00, Effective date 8/21/2017. Based on this inconclusive hypothesis, you retested the samples for dissolution and based on the passing results, you invalidated the initial OOS results. B. On 12/5/2022, the lab recorded OOS result PIT/OOS/2020/051 for test by HPLC. The OOS result was reported for one of the batches out of the three batches run in the same sequence: Batch No. (b) (4) (result %, Stability Sample 25 ± 2 (b) (4) ((b) (4) Tablet mg, non-US market) (result 9 month) and Batch No. (b) (4) (b) (4) Stability Sample 25 ± 2℃/60 ± 5 %RH, 3 month) against the Specification. You tested the sample using test procedure, STP No. TP/AS/0950/00 Assay (By HPLC) for Tablets, Effective date 10/25/2019, in line with your analytical method validation report, AMV/R/2017/010/00, Effective date 8/23/2017. In the Phase IA of the investigation, no assignable root cause was identified. In Phase IB investigation no laboratory error was identified. However, you suspected preparation stage as the probable cause. You attempted to verify higher assay value from "improper (b) (4)" through a hypothesis test by re (b) (4) a passing assay result %). From these results, you concluded "error in cause and you further stated that the analyst might have applied higher pressure that might have (b) (4) and caused higher assay. Your investigation stated that all the three samples that were analyzed in the sequence were prepared (b) (6) by the same analyst (Ms. who was trained in the sample preparation. Also, you did not investigate why a (b) (4) will cause higher assay value than the higher end of the Specification, (b) (4) (b) (4) was (b) (4). Based on this inconclusive hypothesis, you retested the samples for assay and based on the passing results, you invalidated the initial OOS results. C. On 11/29/2021, the lab recorded OOS result PIT/OOS/2021/035 for test by HPLC. The OOS result was reported for one of the batches out of the three batches run in the same sequence: Batch No. (b) (4) (result (b) (4)%, Finished product), Batch No. (b) (4) (b) (4) market) (result %, Finished product), and (b) (4) market) (result %, Finished product) against the Specification. You tested the sample using test procedure, STP No. TP/AS/0278/01 Assay Test for date 11/13/2014, in line with your analytical method validation report, PRO/SIM/01/01/51/MUM, Effective date 9/16/2007. In the Phase IA of the investigation, no assignable root cause was identified. In Phase IB investigation no laboratory error was identified. However, you suspected (b) (4) preparation stage and/or of the vial (for HPLC) as the probable cause. You attempted to verify higher assay value from (b) (4) issue and/or refilling the sample and te

      Shortened here; the PDF has the full text.

    2. Observation 2

      Missing production phase time limits

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. Specifically, The (b) (4) data for the (b) (4) the hold time studies such that, A. You carried out hold time study for (b) (4) (b) (4) per your Protocol No. HTS/ -001/00 (Effective date 1/22/2022) and established time for the (b) (4) as per the Report No. HTR. According to the hold time study protocol, you collected the samples for hold time study from the in-process bulk container, IBC-057 at the completion of the 005. The hold time sample was analyzed for appearance. The only (b) (4) data you collect is for the samples collected from the 005 at the completion of (b) (4) stage as per your process validation protocol, PPQP/PIT/ /2022/00 (Effective date 1/22/2022). The (b) (4) not analyzed for (b) (4). You use compression. B. You carried out hold time study for (b) (4) your Protocol No. HTS/CAB-001/00 (Effective date 10/5/2013) and established for the (b) (4) as per the Report No. HTR/CAB-001/00 (Effective date 7/28/2015). According to the hold time study protocol, you collected the samples for hold time study from the in-process bulk containers, IBC-013 and IBC-061 at the completion of the ID-MFG-017. The hold time sample was analyzed for description, and related compound. The only (b) (4) from the (b) (4) ID-MFG017 at the completion of validation protocol, PVP/CAB-001/00 (Effective date 10/5/2013). The the IBC-013 and IBC-061 is not analyzed for IBC-013 and IBC-061 for tablet compression. C. You carried out hold time study for (b) (4) (b) (4) mg as per your Protocol No. HTS/CBD-001/00 (Effective date 2/6/2014) and established (b) (4) hold time for the (b) (4) 8/4/2015). According to the hold time study protocol, you collected the samples for hold time study from the in-process bulk container, IBC-062 at the completion of the (b) (4) ID # MFG-165. The hold time sample was analyzed for appearance, and degradation products. The only (b) (4) from the (b) (4) ID # MFG-165 at the completion of validation protocol, PVP/CDB-001/00 (Effective date 2/6/2014). The IBC-062 is not analyzed for (b) (4) tablet compression. D. You carried out hold time study for (b) (4) as per your Protocol No. HTS/EFH-001/00 (Effective date 11/16/2013) and established hold time for the (b) (4) as per the Report No. HTR/EFH-001/00 (Effective date 3/4/2015). According to the hold time study protocol, you collected the samples for hold time study from the in-process bulk containers, IBC-014 and IBC-046 at the completion of the process on (b) (4) ID # MFG-011. The hold time sample was analyzed for description, (b) (4) assay, and related substances. The only collected from the (b) (4) ID # MFG-011 at the completion of process validation protocol, PVP/EFH-001/00 (Effective date 11/7/2013). The stored in the IBC-014 and IBC-046 is not analyzed for stored in IBC-014 and IBC-046 for tablet compression. Your General Manager of Quality Assurance (Mr. RS) stated that the for the (b) (4) in the (b) (4) is extrapolated to the Hold time sample. Your hold time study data are inadequate for the (b) (4) (b) (4) stored in IBC bins that was/is actually used in the drug product manufacturing. Between 2020 and 2023, you have recorded at least twelve OOS results related to assay including (b) (4) assay, content uniformity, and dissolution. You have invalidated 10 of the aforementioned OOS results. Some of the drug products that are implicated with assay related OOS results, including but are not limited to; (b) (4) (b) (4) mg, (b) (4) tablets (b) (4) (b) (4) tablets mg, (b) (4) mg.

    Show observations 3 to 8
    1. Observation 3

      UV dissolution methods lack system suitability

      The suitability of all testing methods is not verified under actual conditions of use. Specifically, Your firm uses the UV method to quantitate the release of drug product in dissolution testing of (b) (4) drug products. However, the sample sequence described in your UV methods (one blank, one standard, one sample) for (b) (4) of the (b) (4) drug products did not establish the system suitability whenever the method was used for dissolution testing. Your firm has been using the UV methods without system suitability established to test the dissolution of the (b) (4) drug products for batch release and stability study since each the Agency (refer to the table below). Without demonstrating system suitability, all the dissolution data analyzed by the UV method for the commercial and exhibit batches of your (b) (4) corresponding batches may not be reliable. Among the (b) (4) approved and are pending. Table: System Suitability and Data Validity in UV Method for Dissolution Testing of Products (b) (4) # (b) (4)Drug Products (b) (4) Commercialized (b) (4)

    2. Observation 4

      Inadequate cleaning of shared equipment

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, major non-dedicated production equipment such as (b) (4) ID: MFG-159) and two (b) (4) (equipment ID: MFG-162 and MFG-163) used in (b) (4) Area are not cleaned, and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality, or purity of the drug product. For example: A. On 6/19/2023, during the inspection of the that was labeled "Clean", significant scratches were observed inside the (potential contact surface) and (b) (4) (b) (4). Scratches/dents were more apparent on the (change over cleaning) and verified by Quality on 6/14/2023. DGM Production stated, in the past, the firm had been using (b) (4) the (b) (4) and to dismantle the stopped using (b) (4) impacted equipment and did not perform any risk assessment if specifically, this issue has impacted any marketed batches. B. After the process (b) (4) (b) (4) equipment IDs: MFG-162 and MFG-163) in with the "Clean" (b) (4) ID: MFG (b) (4) ID: MFG-162 and MFG-163 respectively. During the inspection, the inside these (b) (4) to (b) (4) various locations with the unknown residue that appeared to be buildup. Type-A (change over) cleaning was performed and verified on both equipment on 6/14/2023. (b) (4) (b) (4) area and the production equipment inside this area such as: MFG-159, MFG-162-T1 and 1 are shared use equipment. This equipment is used to manufactured following drugs: (b) (4) (b) (4) (b) (4) Tablets mg, mg), (b) (4) (b) (4) (b) (4) Tablets mg),(b) (4)

    3. Observation 5

      Deficient dissolution test execution

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, scientifically sound, and appropriate test procedures are not deployed to establish the identity, strength, quality, and purity of the drug products manufactured at the site. For example: On 6/19/2023, I observed the dissolution test that was performed for (b) (4) using Dissolution autosampler. Both batches were stability batches stored under long-term stability conditions (25 C, 60% RH) and were tested for dissolution at 24-month TP/DR/0178. This test method requires, dissolution test to run for (b) (4) the speed of rpm. Batch (b) (4) did not pass the S-1 dissolution stage and was tested for S-2 stage on 6/21/2023. Following deficiencies were observed when lab analyst performed the test: A. The dissolution test did not start when the media. Instead, the test was manually started after about temperature sensor read the temperature of the dissolution media in the specified range i.e., (b) (4) B. After the completion of the (b) (4) draw sample from the dissolution vessel) in (b) (4) sample is pulled in cycles (about (about (b) (4) before the actual dissolution sample is pulled by the autosampler. During this time, the baskets containing the tablets do not stop; instead, they keep (b) (4) of rpm. It appeared the (b) (4) for about (b) (4) when the autosampler completed the sampling process. C. Rinsing of the sample tubes is done as per Protocol 5, programmed in the dissolution apparatus. This protocol requires removal of about dissolution sample has been drawn. At the end of the test, when rinsed solution from all dissolution vessels was measured it was about missing. This dissolution equipment (ID: QCD-333) along with other similar dissolution equipment are used by the firm to perform dissolution profile test for about following (b) (4) Tablets.

    4. Observation 6

      QC failed to control LES test methods

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, the quality unit failed to control the laboratory test methods created and then transferred in LES Development server as per SOP CSOP/2016/047, "Method Creation on Method Builder Software". Computerized system LES (Laboratory Execution System) is used by the quality control laboratory for documentation and to perform analysis. Production. Test methods are created as per SOP CSOP/2016/047, "Method Creation on Method Builder Software" and then moved in LES Development server. After verification, the test methods in Development server are transferred on Production server. CSOP/2016/047 requires all methods to be names with the product such as (b) (4) USP. However, it was observed numerous procedures (about more than 60) were not associated with any product. Instead, the procedure name w Test, 0, 123, *, Test 123, Testing, TESTING" etc. Few examples are shown as below: CATEGORY PROCEDURE NAME Formulation Testing Formulation Testing Formulation TRIAL Formulation Testing Raw Material Testing Formulation TRIAL API Testing Testing Testing_123 API Testing Formulation TEST Formulation test Formulation Testing Finished TEST Goods Formulation Test Formulation Test Formulation Test Formulation Testing Testing Testing Finished Testing Goods FG Test

    5. Observation 7

      Soiled and torn manufacturing gowning

      Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, personal gowning used in the compression areas is not maintained clean (b) (4) inspection of Dispensing Room and Compression Area used in the respective area appeared worn out and torn (with holes measuring more than 2 inches). It appeared soiled with black, white, (b) (4). In the core manufacturing areas, additional PIT/MGG/002/19. During the inspection of Dispensing Area were observed on the "Clean; intended to be used in the dispensing room" arm sleeves. One sleeve appeared to be torn. Additionally, bottom fabric of the "Clean" booties intended to be used in the dispensing area appeared worn out at numerous places exposing the underneath padding. On 6/15/2023, an operator wearing the gowning with excessive stains and marks was observed inside the Compression (b) (4) Area where (b) (4) is compressed into tablets. Your Laundry Procedure (# PIT/HRD/028/14) requires checking the gowning for any damaged and torn aprons, booties, and trousers before washing. As per this SOP such gowning should not be considered for next washing cycle. In this regard, you failed to follow your procedure to ensure clean gowning is used in the core manufacturing areas.

    6. Observation 8

      Ineffective CAPA for no-label complaints

      Procedures describing the handling of all written and oral complaints regarding a drug product are not written and followed. Specifically, Your firm’s Corporate Standard Operating Procedure for Handling of Product Complaint (CSOP/2013/004; Number: CSOP/2013/004/R09, Effective Date: June 02, 2022; CSOP/2013/004/R08, Effective Date: Feb 03, 2022; CSOP/2013/004/R07, Effective Date: Sept 16, 2020) requires that all CAPAs initiated in reference to product complaints shall be reviewed for effectiveness check; if the CAPA is found to be ineffective, a new CAPA shall be assigned by reinvestigating the complaint. Your firm received four complaints regarding the issue of no label on the bottle of mg from your (b) (4) client in 2021 (refer to the table below). Your firm classified the no-label complaints as major, conducted investigations, and implemented CAPA/Change Control (CAPA# 202191) in 06/2021. Your firm also performed a CAPA effectiveness check and closed the CAPA in 07/2021. However, the same no-label issue re-occurred for the same drug product four times in 2022 and twice to date in 2023 (refer to the table below), demonstrating your CAPA is not effective. Your firm did not assign a new CAPA to investigate the new complaints. Table: No-Label Complaints from 2021 to 2023 Complaint # Complaint Received Date MKT/034/2021 06/04/2021 MKT/059/2021 09/08/2021 MKT/069/2021 11/10/2021 MKT/073/2021 12/23/2021 MKT/009/2022 03/01/2022 MKT/012/2022 03/28/2022 252465 10/07/2022 252504 10/07/2022 272501 03/31/2023 276943 05/09/2023

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written program not followed

      The written stability testing program is not followed.

    2. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.

    3. Calculations performed are in the records

      Laboratory records do not include a record of all calculations performed in connection with the test.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Ipca Laboratories LimitedD-U-N-S 650387009

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Ipca Laboratories Limited (D-U-N-S 650387009) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Ipca Laboratories LimitedRatlam, India · FEI 30028072974 inspections4latestOct 21, 2023VAI1 warning letter, Jan 29, 2016
  • Ipca Laboratories LimitedSilvassa, India · FEI 30059776755 inspections5latestApr 26, 2023VAI1 warning letter, Jan 29, 2016
  • Ipca Laboratories LimitedPalghar, India · FEI 30060571013 inspections3latestDec 5, 2025VAINone on file
  • IPCA LABORATORIES LIMITEDChhatrapati Sambhajinagar, India · FEI 30092279291 inspection1latestNov 4, 2016NAINone on file
  • Ipca Laboratories LimitedGujarat, India · FEI 3027770072Registered; no FDA inspection on file
  • Ipca Laboratories LimitedMadhya Pradesh, India · FEI 3027770075Registered; no FDA inspection on file

Other FEIs recorded as Ipca Laboratories Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3007574780 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3007574780. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.