Ipca Laboratories Limited
2 Plot No E - 41, And E - 128; E - 129 Midc Tarapur Boisar, Palghar, India
FEI 3006057101DUNS 918580838
Company: Ipca Laboratories Limited · Linked by exact D-U-N-S match (650387009) in FDA registration data
FDA has 3 inspections on file for Ipca Laboratories Limited in Palghar, India (FEI 3006057101), from 2016 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Three FOIA requests have asked FDA for this inspection's records.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Ipca Laboratories Limited (D-U-N-S 650387009), has registered 6 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2016–2025
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Apr 1, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Poor facility maintenance/cleaning
OBSERVATION 1 Buildings and facilities used to manufacture cleaning and to minimize potential contamination. Specifically, the clean rooms in manufacturing block (b)(4) USP for the US market, are not maintained appropriately to facilitate cleaning and to minimize potential contamination. For example: A. On 12/1/2025, during the inspection a chunk (approximately 5 inches long and 2.5 inches wide) was observed on the ceiling where (b)(4) [illegible] housed. This is an open processing area where the APIs are exposed to the room environment. You failed to adequately maintain this area to ensure chipping and peeling impacting the quality of the APIs manufactured in this room. B. On 12/1/2025, during the inspection approximately more than 20 small cracks were observed on the walls and ceiling. This area houses two major production equipment (equipment ID: 10(b)(4)-01). This is an open processing area where finished APIs are exposed to the room environment. You failed to ensure that the area is adequately maintained to facilitate cleaning and to minimize potential contamination. These areas are routinely inspected, maintained, and cleaned per TARA/PRD/004/R03, Housekeeping of Manufacturing - Maintenance of Premises. During routine facility inspection, maintenance, and cleaning, you failed to identify and repair the impacted surfaces. Manufacturing Block (b)(4) including (b)(4) shipping both products to the US.
- Observation 2
Deficient analytical method verification
OBSERVATION 2 The suitability of analytical test methods is deficient for its intended use. Specifically, analytical method verification studies performed to test assay and organic impurities in (b)(4) SP are deficient. On 12/2/2025, you tested US batches of (b)(4) SP using two HPLCs. The equipment QC-INST-07 was used for Assay by HPLC, and equipment QC-INST-06 was used for Organic Impurities by HPLC. The HPLC column temperature was set at [illegible] °C. A change in column temperature can cause change and potentially impact the analysis. The site failed to provide any scientific data generated through a controlled study to demonstrate that the HPLC column temperature range [illegible] and accurate results. On 7/31/2025, you initiated an out of specification investigation for (b)(4) (b)(4) results of 20 (specification: 1% to (b)(4)). (b)(4) was tested for assay at 12-month long-term stability interval. During the investigation, you observed that the retention time of the main peak shifted during the analysis that might have impacted the analysis.
Show observation 3
- Observation 3
Inadequate cleaning/carryover controls
OBSERVATION 3 There is a lack of adequate controls in place to minimize the carryover between successive batches of the same intermediate or API. Specifically, you failed to establish the maximum number of days or maximum campaign length in a campaign. For example: Your control procedure TARA/PRD/088/R01, Manufacturing Process Equipment, requires Type-B cleaning (more rigorous cleaning) of equipment be performed between the different products. This procedure does not define the campaign length in terms of maximum number of days. For example, two manufacturing campaigns for (b)(4) and (b)(4) SPI lasted for (b)(4) days and (b)(4) days, respectively. You failed to provide scientific data derived through a controlled study to demonstrate that the residual material from the previous batch is not carried over into the next batch. Procedure, Criteria, and Validity for Cleaning of the process does not define the maximum number of days for which the APIs can be manufactured before or after (b)(4) batch of the same product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Apr 1, 2026.
Inspection ending Dec 5, 2025VAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Apr 1, 2026FDA-FOIA-2026-3260Form 483· 1 of 21 sitesClosed over fees
- Dec 17, 2025FDA-FOIA-2025-14131Inspection recordsRecords released
- Dec 15, 2025FDA-FOIA-2025-13974Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Ipca Laboratories LimitedD-U-N-S 650387009
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Ipca Laboratories Limited (D-U-N-S 650387009) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Ipca Laboratories LimitedRatlam, India · FEI 30028072974 inspections4latestOct 21, 2023VAI1 warning letter, Jan 29, 2016
- Ipca Laboratories LimitedDhar, India · FEI 30075747804 inspections4latestJun 23, 2023VAI1 warning letter, Jan 29, 2016
- Ipca Laboratories LimitedSilvassa, India · FEI 30059776755 inspections5latestApr 26, 2023VAI1 warning letter, Jan 29, 2016
- IPCA LABORATORIES LIMITEDChhatrapati Sambhajinagar, India · FEI 30092279291 inspection1latestNov 4, 2016NAINone on file
- Ipca Laboratories LimitedGujarat, India · FEI 3027770072Registered; no FDA inspection on file
- Ipca Laboratories LimitedMadhya Pradesh, India · FEI 3027770075Registered; no FDA inspection on file
Other FEIs recorded as Ipca Laboratories Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Ipca Laboratories LimitedFEI 3005888508Mumbai, India
Last inspected 2017-03-08VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3006057101 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3006057101. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.