Ipca Laboratories Limited
Plot No. 65, 99 and 126, Danudyog Industrial Estate, Piparia, Silvassa, India
FEI 3005977675DUNS 918917303
Company: Ipca Laboratories Limited · Linked by exact D-U-N-S match (650387009) in FDA registration data
FDA has 5 inspections on file for Ipca Laboratories Limited in Silvassa, India (FEI 3005977675), from 2010 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 23, 2019. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Ipca Laboratories Limited (D-U-N-S 650387009), has registered 6 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2023
- 2 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 5
- Requested under FOIA
- 4 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate OOS/OOT results
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, OOS A. Your firm failed to follow validated analytical test method AMV/SIM/07/00 (Effective date 6 Jul 2007) and conduct a complete investigation as established in Specification Result Management (Effective date 14 May 2022). For example, on 29 Nov 2022, your firm reported an OOS test by HPLC for [illegible] (b)(1) mg tablets Batch No. [illegible] (non-US market). This OOS result was reported for the low assay value of [illegible] (Specification [illegible]). The Phase I investigation did not reveal any assignable root cause. Your firm proceeded to Phase IIB without conducting the Phase IIA-Manufacturing Investigation. Based on the higher assay results obtained from the [illegible] samples (non-validated method) compared to [illegible], your firm determined the root cause as "probably [illegible] which lead to lower result." The assay results were analyzed in the same sequence under hypothesis testing as follows: Batch No. [illegible] (passing batch) and Batch No. [illegible] (batch with OOS result). Your firm used this probable root cause to retest the batch to invalidate the initial OOS result. Your firm has not established a scientifically sound justification that the [illegible] due to [illegible] will not cause a lower value of assay for the batches analyzed. B. Your firm invalidated an OOS result without a complete investigation. In Jan 2020 your firm reported an OOS No. SIL/OOS/2020/004 for a [illegible] (b)(1) mg tablets (non-US market). The Phase I investigation did not reveal an assignable root cause with sample preparation. According to the Record of Analysis A.R. No. [illegible], your analyst designed a hypothesis test and prepared the test to compare with a [illegible] sample. Your firm used two (2) completely different [illegible] sample preparations to retest the batch for passing assay value and invalidated the OOS without establishing a scientifically justified root cause. Analytical method validation report AMV [illegible] (Effective date 12 May 2016) confirmed that test sample is prepared by [illegible]. C. Your firm failed to follow validated analytical test method AMV/SIM/07/00 (Effective date 6 Jul 2007) for [illegible] and conduct a complete investigation as established in Out of Trend (OOT) Identification and Investigation CSOP/2018/155/R09 (Effective date 18 Jan 2023). On 24 Nov 2022, your firm reported an OOT OOT/QC/SIL/015 for [illegible] (DH[illegible]) [illegible] mg tablets Batch No. [illegible] (non-US market). The OOT result was reported for a lower assay value. The Phase I investigation did not reveal any assignable root cause. Your firm proceeded to Phase IIB without conducting the Phase IIA-Manufacturing Investigation. Based on the higher assay results obtained from the [illegible] samples (non-validated method) compared to [illegible], your firm determined the root cause as "probably [illegible] which lead to lower result." The batches initially recorded OOT and OOS results whereas your firm failed to establish a scientifically sound justification for the root cause before concluding that the [illegible] due to [illegible] will only cause a lower value of assay for the initially recorded OOT and OOS results. Your firm used an [illegible] to retest the batch to invalidate the initial OOT result. Your firm failed to follow established OOT procedure CSOP/2018/155/R09 Out of Trend (OOT) Identification and Investigation (Effective date 18 Jan 2023) such that you did not conduct Manufacturing Investigation as per Section 5.4.5. In addition, analytical test method [illegible] Protocol No. SIL/AMV/SIM/07/00 reported [illegible] powder was used. Although the specific procedure to obtain [illegible] was mentioned in the procedure, your Senior Manager QC (PP) stated that [illegibl
Shortened here; the PDF has the full text.
- Observation 2
Inadequate deviation/CAPA management
The responsibilities and procedures applicable to the quality control unit were not followed. Specifically, your firm failed to ensure deviation investigations and associated corrective and preventive actions (CAPAs) were timely, accurate, and documented consistent with the associated CAPAs including but not limited to: a. PR #206678 dated 20 Jul 2021 — where the tablet inspection system was not working and steps in the investigation were not documented and was not closed for a total of 10 months without justification. b. PR #185131 dated 12 Dec 2020 and associated CAPA No. 194953 dated 17 Mar 2021 — documentation and timing deficiencies during the analysis. c. PR #142411 dated 03 Sept 2019 and associated CAPA 210533 dated 28 Aug 2021 — where the Dissolution Test by UV for [illegible] (DH[illegible]) in the [illegible] (Reviewed by 3rd party consultant). d. PR #152326 dated 17 Dec 2019 and associated CAPA 207[illegible] — wrong manufacturer name was added to the [illegible] (reviewed by 3rd party consultant) were re-opened; however, the date that the remediation activities began is not captured, so it cannot be determined how long the deviation investigations were open, and if appropriate time frames were met. Furthermore, QA managers reported that they did not want it to appear as though the investigations were open long due to non-availability of the 3rd Party Consultant. For example, CAPA No. 194953 associated with Deviation PR#185131 was entered into Trackwise. However, once documentation was entered on 12 Dec 2020, a new (later) due date was documented 24 days later, which is outside the time frame established by your firm. Your QA Manager reported that Trackwise automatically calculated this due date. However, the due date was not until [illegible] and the justification for the extended completion before a justification is required was not documented. B. On 29 Jan 2020 your firm recorded an OOS for dissolution for [illegible] mg Tablet Batch No. [illegible] (Stability Study, 40 ± 2 °C/75 ± 5% RH). Your firm determined human error as the root cause where the analyst did not ensure the tablet was placed in the respective vessel. Your firm implemented CAPA 159233 and updated procedures with instructions as follows, "analysts shall ensure that the tablets are dropped in respective bowl prior to start dissolution program". In addition, the CAPA states "Training to be imparted to concerned persons to ensure that each tablet is present in particular vessel." The procedures that were updated; SOP/QCD/201/05 Operation and Cleaning Procedures for Dissolution Test Apparatus (Effective date 9 Feb 2022), SOP/QCD/243/02 Operation and Cleaning Procedures for Dissolution Test Apparatus (Effective date 2 Apr 2022), and SOP/QCD/123/05 Procedure for Performing Dissolution Profile Study (Effective date 6 Apr 2022). On [illegible] your firm recorded another OOS for [illegible] mg Tablet Batch No. [illegible] (Stability Study, 25 ± 2 °C/60 ± 5% RH). Your firm again identified human error where the analyst did not ensure the tablet was placed in respective vessels to a particular vessel. The earlier CAPA was implemented, and procedures were updated. According to the investigation, the analyst was trained on the revised procedure. This confirmed that the CAPA was not effective.
Show observation 3
- Observation 3
Insufficient quality unit authority and data control
Your firm failed to establish an adequate quality unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products. Specifically, your quality unit (QU), to include Quality Assurance (QA) and Quality Control (QC), lacked adequate responsibilities and authorities to assure reliable operations. The quality system does not adequately ensure the accuracy and integrity of the data for the drug(s) you manufacture. For example, including, but not limited to the following: a. The HMI for the [illegible] system does not have an audit trail and is not retrievable. Your firm-initiated change control was left open. Your firm documented this change control as [illegible]; data integrity has not been addressed in this investigation. b. During a walkthrough of the Microbiology Laboratory, we observed media preparation and the Logbook for Daily Calibration Verification Record to have consistent non-readable printouts which were signed by the Microbiologist and not reviewed by Quality Assurance (QA) and the data was not fully recorded. For example, 16 Mar 2023 the balance printout was illegible. The balance was under maintenance by the Manufacturer, who also printed a non-readable document from the balance and signed off without acknowledging the deficiency. There is no preventive maintenance program established for this equipment. The "Cleaning Operation, and Calibration Practices" and the "Preventive Maintenance Procedure" do not establish requirements for maintaining quality related data beyond hardcopy printouts. There is no procedure describing how to adhere the printout to a page. c. Your firm failed to document the start time and length of investigations; the length of investigations is unknown and unable to be controlled by the Quality Unit. For example, your QA Manager reported that your firm did not maintain control of the remediation activities and that some deviation investigations began in Trackwise but documentation began later. PR#185131 for an adjustment procedure was not implemented and closed for seven months. There are repeated data integrity issues and loss of readable quality related data. PR ID 258680 dated 05 Dec 2022 is still open with "Risk identified is low". The lapse in data integrity and analyses of the observed data indicate the potential that quality related data is lost and corrective actions were not timely or effective.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Deviations from laboratory control requirements
Deviations from written test procedures and laboratory mechanisms are not recorded and justified.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Adverse Drug Experience
Complaint procedures are deficient in that they do not include provisions that allow for the review to determine if the complaints represent serious and unexpected adverse drug experiences which are required to be reported to FDA.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Show 4 more citations
In-process materials specifications
In-process specifications are not derived from previous acceptable process average and process variability estimates where possible and determined by the application of suitable statistical procedures where appropriate.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing and instructions.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Aug 23, 2019OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 26, 2019FDA-FOIA-2019-7657Form 483Open
Inspection date not given
3 requests.
- FY2023FDA-FOIA-2023-3749Form 483Closed
- FY2023FDA-FOIA-2023-3495Form 483Closed
- Aug 26, 2019FDA-FOIA-2019-7667Form 483Open
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Show all 10
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3005977675, one row per refused product line.
1 refusal on 2023-04-18 · charged DRUG GMPS on 1 · no FDA sample analysis
FDA firm profile- 2023-04-18
ACETAMINOPHEN (ANALGESIC)60LDY01
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-7100250-8/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Ipca Laboratories LimitedD-U-N-S 650387009
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Ipca Laboratories Limited (D-U-N-S 650387009) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Ipca Laboratories LimitedRatlam, India · FEI 30028072974 inspections4latestOct 21, 2023VAI1 warning letter, Jan 29, 2016
- Ipca Laboratories LimitedDhar, India · FEI 30075747804 inspections4latestJun 23, 2023VAI1 warning letter, Jan 29, 2016
- Ipca Laboratories LimitedPalghar, India · FEI 30060571013 inspections3latestDec 5, 2025VAINone on file
- IPCA LABORATORIES LIMITEDChhatrapati Sambhajinagar, India · FEI 30092279291 inspection1latestNov 4, 2016NAINone on file
- Ipca Laboratories LimitedGujarat, India · FEI 3027770072Registered; no FDA inspection on file
- Ipca Laboratories LimitedMadhya Pradesh, India · FEI 3027770075Registered; no FDA inspection on file
Other FEIs recorded as Ipca Laboratories Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Ipca Laboratories LimitedFEI 3005888508Mumbai, India
Last inspected 2017-03-08VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3005977675 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3005977675. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.