FDA has one inspection on file for New Era Pharmacy, LLC in Portland, Oregon (FEI 3003429652). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-sterile apparel in ISO 5 cabinet
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 11/22/19, an employee was observed wearing a non-sterile face mask and a non-sterile knee-length gown. The non-sterile sleeves of his gown were inside the ISO 5 Biological Safety Cabinet during sterile production of HCG Microdose 1000 IU/10 mL (50 IU/0.5 mL) Injectable, Lot HM-1122S19, expiration date 12/6/19.
- Observation 2
ISO 5 areas not certified dynamically
ISO-5 classified areas were not certified under dynamic conditions. Specifically, the dynamic smoke studies conducted on 10/16/19 and 4/3/19 in the ISO 5 Bio-Safety Cabinet used to produce hazardous drugs and ISO 5 Laminar Flow Hood used to produce non-hazardous drugs are inadequate in that there are no videos or adequate written description available to verify the operator movement, interventions, equipment, etc.
Show observations 3 to 4
- Observation 3
Media fills do not simulate worst-case operations
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills are not performed in a manner that simulates challenging production practices such as maximum number of people in the room, the duration of aseptic production and representative container type and size used during routine aseptic operations. For example: A) The media fill for high risk production include filling of (b)(4) vial which does not represent all vial sizes such as (b)(4) in a 10 ml vial and (b)(4) in a 2 mL vial and (b)(4) in a 10 mL plastic dropper container used for ophthalmic products. B) The media fill for low/medium risk production includes filling of (b)(4) vial sizes such as 10 mL in (b)(4) vial and (b)(4) in a 2 mL vial.
- Observation 4
Non-pharmaceutical grade components in non-sterile drugs
Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, your firm has been using non-pharmaceutical grade (b)(4) ((b)(4)) in the production of non-sterile drug products. For example: A) Your firm used non-pharmaceutical grade (b)(4) to prepare (b)(4) (b)(4) and other solutions such as (b)(4) solution that were used in the production of non-sterile drug products. Some examples include: 1) Omeprazole (SP) 4 mg/mL Suspension, Lot O111219@5 that was made on 11/12/19 used (b)(4) (b)(4) solution prepared using (b)(4), Lot (b)(4). 2) Oxytocin Nasal Spray 125 units/mL Liquid, Lot O081319@4 that was made on 8/13/19 used (b)(4) (b)(4) Liquid prepared using (b)(4), Lot (b)(4). 3) Buprenorphine (VET) 0.3 mg/mL Solution, Lot 11252019@5 that was made on 11/25/19 used (b)(4) Liquid prepared using (b)(4), Lot (b)(4). 4) Omeprazole (SP) 5 mg/mL Suspension, Lot 11062019@4 that was made on 11/6/19 used (b)(4) (b)(4) solution prepared using (b)(4), Lot (b)(4). B) In addition, your firm does not perform analytical or microbiological testing of this non-pharmaceutical grade (b)(4) to show if (b)(4) meets the specifications for (b)(4).
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003429652 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003429652. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.