Skip to content

New Era Pharmacy, LLC Form 483, November 2019

FDA issued this Form 483 to New Era Pharmacy, LLC in Portland, Oregon (FEI 3003429652) at the end of a drug inspection that ended November 27, 2019. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 27, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Nov 27, 2019
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jan 27, 2020
61 days after the inspection
Facility
FEI 3003429652
Portland, Oregon

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Non-sterile apparel in ISO 5 cabinet

    Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 11/22/19, an employee was observed wearing a non-sterile face mask and a non-sterile knee-length gown. The non-sterile sleeves of his gown were inside the ISO 5 Biological Safety Cabinet during sterile production of HCG Microdose 1000 IU/10 mL (50 IU/0.5 mL) Injectable, Lot HM-1122S19, expiration date 12/6/19.

  2. 2

    ISO 5 areas not certified dynamically

    ISO-5 classified areas were not certified under dynamic conditions. Specifically, the dynamic smoke studies conducted on 10/16/19 and 4/3/19 in the ISO 5 Bio-Safety Cabinet used to produce hazardous drugs and ISO 5 Laminar Flow Hood used to produce non-hazardous drugs are inadequate in that there are no videos or adequate written description available to verify the operator movement, interventions, equipment, etc.

  3. 3

    Media fills do not simulate worst-case operations

    Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills are not performed in a manner that simulates challenging production practices such as maximum number of people in the room, the duration of aseptic production and representative container type and size used during routine aseptic operations. For example: A) The media fill for high risk production include filling of (b)(4) vial which does not represent all vial sizes such as (b)(4) in a 10 ml vial and (b)(4) in a 2 mL vial and (b)(4) in a 10 mL plastic dropper container used for ophthalmic products. B) The media fill for low/medium risk production includes filling of (b)(4) vial sizes such as 10 mL in (b)(4) vial and (b)(4) in a 2 mL vial.

  4. 4

    Non-pharmaceutical grade components in non-sterile drugs

    Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, your firm has been using non-pharmaceutical grade (b)(4) ((b)(4)) in the production of non-sterile drug products. For example: A) Your firm used non-pharmaceutical grade (b)(4) to prepare (b)(4) (b)(4) and other solutions such as (b)(4) solution that were used in the production of non-sterile drug products. Some examples include: 1) Omeprazole (SP) 4 mg/mL Suspension, Lot O111219@5 that was made on 11/12/19 used (b)(4) (b)(4) solution prepared using (b)(4), Lot (b)(4). 2) Oxytocin Nasal Spray 125 units/mL Liquid, Lot O081319@4 that was made on 8/13/19 used (b)(4) (b)(4) Liquid prepared using (b)(4), Lot (b)(4). 3) Buprenorphine (VET) 0.3 mg/mL Solution, Lot 11252019@5 that was made on 11/25/19 used (b)(4) Liquid prepared using (b)(4), Lot (b)(4). 4) Omeprazole (SP) 5 mg/mL Suspension, Lot 11062019@4 that was made on 11/6/19 used (b)(4) (b)(4) solution prepared using (b)(4), Lot (b)(4). B) In addition, your firm does not perform analytical or microbiological testing of this non-pharmaceutical grade (b)(4) to show if (b)(4) meets the specifications for (b)(4).

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3003429652, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.