Skip to content

Pillar5 Pharma Inc.

365 Madawaska Blvd,, Arnprior, Canada

FEI 3000241849DUNS 243303631

FDA has 10 inspections on file for Pillar5 Pharma Inc. in Arnprior, Canada (FEI 3000241849), from 2008 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Dec 15, 2023. 1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing and labeling, through Dec 31, 2026. Its registrant is Pillar5 Pharma Inc (D-U-N-S 243904344).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
10, 2008–2026
1 OAI · 6 VAI · 3 NAI
Inspections with 483 observations shown
6 of 10
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
5 requests, latest Aug 17, 2026
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity.

    2. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.

    3. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    4. Drug product reserve containers

      Drug product reserve samples are not stored in an immediate container-closure system that has essentially the same characteristics as the marketed product.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    Show 4 more citations
    1. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    2. Written program not followed

      The written stability testing program is not followed.

    3. Laboratory equipment calibration records

      Laboratory records do not include complete records of the periodic calibration of laboratory instruments.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

    2. Establish reliability of supplier's C of A

      Establishment of the reliability of the container and closure supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. 21 CFR 11

      Electronic records

      Electronic records are used, but they do not meet retention, audit trail and systems documentation control requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    2. Incoming lots - conformance to written specs-

      Laboratory controls do not include determination of conformance to appropriate written specifications for the acceptance of each lot within each shipment of components used in the manufacture, processing, packing, or holding of drug products.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining appropriate storage conditions.

    2. Written program not followed

      The written stability testing program is not followed.

    3. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.

    4. Written calibration / inspection records not kept

      Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Aug 17, 2026. Each one asked for a Form 483.

  • Inspection ending Jun 5, 2026VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 15, 2026. FDAgent holds no copy that FDA posted.

    1. Aug 17, 2026FDA-FOIA-2026-7923Form 483· 1 of 2 sitesRecords released
  • Inspection ending Feb 7, 2025VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 24, 2025. FDAgent holds no copy that FDA posted.

    1. Apr 1, 2026FDA-FOIA-2026-3236Form 483Records released
    2. Oct 17, 2025FDA-FOIA-2025-12120Form 483· 1 of 2 sitesRecords released
  • Inspection ending Dec 15, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 15, 2024FDA-FOIA-2024-6166Form 483Closed
  • Inspection ending Feb 21, 2020VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 26, 2026. FDAgent holds no copy that FDA posted.

    1. Nov 24, 2025FDA-FOIA-2025-13239Form 483· 1 of 2 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 10 inspections, with how many of them cited each.

Show all 11

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3000241849, one row per refused product line.

1 refusal on 2021-03-08 · charged NOT LISTED on 1, UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2021-03-08

    PHENYLEPHRINE HCL (ADRENERGIC)60CBK09

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-9416634-4/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Packing, labeling
Registration runs through
Dec 31, 2026
Registrant
Pillar5 Pharma IncD-U-N-S 243904344

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3000241849 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3000241849. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.