Skip to content

Nubratori, Inc.

381 Van Ness Ave Ste 1507, Torrance, California, United States

FEI 3010166491

FDA has 5 inspections on file for Nubratori, Inc. in Torrance, California (FEI 3010166491), from 2018 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

The most recent OAI inspection ended on Jul 26, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.113(b).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2018–2025
1 OAI · 2 VAI · 2 NAI
Inspections with 483 observations shown
3 of 5
Form 483s posted by FDA
↗
3 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    2. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 14 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Observation 1

      Inadequate aseptic process validation

      Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic process. Specifically, A. You do not perform growth promotion studies [(b) (4] for your Media Fills and therefore [illegible] of gram-positive, gram-negative bacteria, yeast, and mold. B. Your firm has not performed product [illegible] Preservative Free using the final distributed container 2mL amber vials, however, all product va[illegible] vials. Dexamethasone 24 mg/ml Injectable is a light sensitive compound. C. Media fill batch records do not reflect all manipulations performed. 1. Your firm includes the use (b) ( ) [illegible] is not used in any of the b)< >4 sterilized, aseptically filled sterile products. 2. During the compounding of Dexamet[illegible] (b) (4) control vial to compare volume in the media fill.

    2. Observation 2

      Deficient environmental monitoring system

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(6 ) I observed that the technician collect their glove fingertip personnel monitoring samples, after wiping a piece sampling equipment with Sterile[(b) (4)], and samples were not taken immediately after completion of aseptic operations. Personnel monitoring samples should be taken before planned disinfection. Technicians did not follow the order listed in the Batch Production Record for sampling.

    Show 12 more observations
    1. Observation 3

      Deficient cleaning/disinfection procedures

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(b) (4)] I observed that the operator failed to wipe down the ISO 7 side [(6) (4)] before opening it to receive materials and failed to clean the legs of the ISO 5 [(6) (4)] air flow hood before aseptic operations.

    2. Observation 4

      Inadequate visual inspection program

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, Your firm's visual inspection program is inadequate. a. You do not document the complete results [illegible] Quality control after the 100% visual inspection and [illegible]. b. Your firm failed to demonstrate that operators can adequately identify defects with the use [illegible] during the visual inspection of Dexamethasone Sodium Phosphate Injection and Dexamethasone Sodium Phosphate/Lidocaine HCl Injection. c. You failed to establish a minimum time for the inspection [illegible] backgrounds. d. Your firm's defect kit is deficient. The library is composed of [illegible] [illegible] of which contain multiple defects in each vial. The defect kit is missing extrinsic, intrinsic, or inherent defects to the manufacturing process such as particulates, and therefore there is no assurance that visual inspectors can identify these defects during visual inspection. e. Your firm failed to establish a statistically sound sampling plan for AQL inspection, that would trigger an investigation and reinspection of the entire batch [illegible] are not classified based on risk. f. You failed to establish a process for incorporating new defects found during [illegible] defect library.

    3. Observation 5

      Missing microbial/endotoxin testing

      Each lot of a component liable to objectionable microbiological [illegible] to microbiological tests before use. Specifically, Acceptance of incoming lots of non-sterile component [illegible] microbial and endotoxin testing and meet limits appropriate [illegible]. Your firm failed to perform microbial and endotoxin testing on all lots of the Bulk Drug Substances (BDS): • Dexamethasone Sodium Phosphate • Lidocaine • Tetracaine HCl These BDS were used to compound the following sterile finished products: • Dexamethasone Sodium Phosphate 24 mg/ml Injectable, Preservative Free BUD 01/19/2025 • 0.4% Lidocaine HCl with 0.2% Tetracaine HCl Injection, BUD 03/14/2025

    4. Observation 6

      Supplier report validation inadequate

      Establishment of the reliability of the component supplier's report results are not appropriately validated at appropriate intervals. Specifically, Your firm failed to conduct full testing as part of the Bulk Drug Substance supplier qualification. Your firm's written procedure is inadequate. The firm has not performed full testing of incoming [illegible] applies to the following BDS: Dexamethasone Sodium Phosphate (Lot [illegible]), Lidocaine HCl (Lot #[illegible]), Tetracaine HCl (Lot [illegible]), Baclofen (Lot [illegible]), Diclofenac Sodium (Lot [illegible]), Gabapentin (Lot [illegible]), Ketamine HCl (Lot [illegible]), Ketoprofen (Lot [illegible]), Naltrexone (Lot [illegible]).

    5. Observation 7

      Missing required 503B six-month report

      Your outsourcing facility has not submitted a report to [illegible] the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, The following product was compounded and not [illegible]: • Diclofenac Sodium 40 mg/2.5 g (16 m[illegible]).

    6. Objectionable microbiological contamination

      Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.

    7. Acceptance criteria for sampling & testing

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.

    8. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    9. FDCA 503B(b)(2)(A)

      All inclusive product report, not submitted

      Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).

    10. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    11. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    12. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    2. FDCA 501(a)(2)(A)

      Disinfectant contact time

      Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Regulations FDA cited here

The 6 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010166491 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010166491. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.