Nubratori, Inc Form 483, July 2024
FDA issued this Form 483 to Nubratori, Inc in Torrance, California (FEI 3010166491) at the end of a drug inspection that ended July 26, 2024. It lists 14 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on January 22, 2025.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Aug 8, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 26, 2024
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Aug 8, 2024
- 13 days after the inspection
The 14 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic process. Specifically, A. You do not perform growth promotion studies [(b) (4] for your Media Fills and therefore [illegible] of gram-positive, gram-negative bacteria, yeast, and mold. B. Your firm has not performed product [illegible] Preservative Free using the final distributed container 2mL amber vials, however, all product va[illegible] vials. Dexamethasone 24 mg/ml Injectable is a light sensitive compound. C. Media fill batch records do not reflect all manipulations performed. 1. Your firm includes the use (b) ( ) [illegible] is not used in any of the b)< >4 sterilized, aseptically filled sterile products. 2. During the compounding of Dexamet[illegible] (b) (4) control vial to compare volume in the media fill.
- 2
Deficient environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(6 ) I observed that the technician collect their glove fingertip personnel monitoring samples, after wiping a piece sampling equipment with Sterile[(b) (4)], and samples were not taken immediately after completion of aseptic operations. Personnel monitoring samples should be taken before planned disinfection. Technicians did not follow the order listed in the Batch Production Record for sampling.
- 3
Deficient cleaning/disinfection procedures
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(b) (4)] I observed that the operator failed to wipe down the ISO 7 side [(6) (4)] before opening it to receive materials and failed to clean the legs of the ISO 5 [(6) (4)] air flow hood before aseptic operations.
- 4
Inadequate visual inspection program
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. Specifically, Your firm's visual inspection program is inadequate. a. You do not document the complete results [illegible] Quality control after the 100% visual inspection and [illegible]. b. Your firm failed to demonstrate that operators can adequately identify defects with the use [illegible] during the visual inspection of Dexamethasone Sodium Phosphate Injection and Dexamethasone Sodium Phosphate/Lidocaine HCl Injection. c. You failed to establish a minimum time for the inspection [illegible] backgrounds. d. Your firm's defect kit is deficient. The library is composed of [illegible] [illegible] of which contain multiple defects in each vial. The defect kit is missing extrinsic, intrinsic, or inherent defects to the manufacturing process such as particulates, and therefore there is no assurance that visual inspectors can identify these defects during visual inspection. e. Your firm failed to establish a statistically sound sampling plan for AQL inspection, that would trigger an investigation and reinspection of the entire batch [illegible] are not classified based on risk. f. You failed to establish a process for incorporating new defects found during [illegible] defect library.
- 5
Missing microbial/endotoxin testing
Each lot of a component liable to objectionable microbiological [illegible] to microbiological tests before use. Specifically, Acceptance of incoming lots of non-sterile component [illegible] microbial and endotoxin testing and meet limits appropriate [illegible]. Your firm failed to perform microbial and endotoxin testing on all lots of the Bulk Drug Substances (BDS): • Dexamethasone Sodium Phosphate • Lidocaine • Tetracaine HCl These BDS were used to compound the following sterile finished products: • Dexamethasone Sodium Phosphate 24 mg/ml Injectable, Preservative Free BUD 01/19/2025 • 0.4% Lidocaine HCl with 0.2% Tetracaine HCl Injection, BUD 03/14/2025
- 6
Supplier report validation inadequate
Establishment of the reliability of the component supplier's report results are not appropriately validated at appropriate intervals. Specifically, Your firm failed to conduct full testing as part of the Bulk Drug Substance supplier qualification. Your firm's written procedure is inadequate. The firm has not performed full testing of incoming [illegible] applies to the following BDS: Dexamethasone Sodium Phosphate (Lot [illegible]), Lidocaine HCl (Lot #[illegible]), Tetracaine HCl (Lot [illegible]), Baclofen (Lot [illegible]), Diclofenac Sodium (Lot [illegible]), Gabapentin (Lot [illegible]), Ketamine HCl (Lot [illegible]), Ketoprofen (Lot [illegible]), Naltrexone (Lot [illegible]).
- 7
Missing required 503B six-month report
Your outsourcing facility has not submitted a report to [illegible] the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act). Specifically, The following product was compounded and not [illegible]: • Diclofenac Sodium 40 mg/2.5 g (16 m[illegible]).
Objectionable microbiological contamination
Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- FDCA 503B(b)(2)(A)
All inclusive product report, not submitted
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterJan 22, 2025Nubratori, Inc. dba Nubratori Rx warning letter, January 22, 2025CDER · 180 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3010166491, newest first.
- Form 483, December 2025Inspection ended Dec 11, 2025 · Posted Jan 22, 2026VAI
- Form 483, September 2019Inspection ended Sep 26, 2019 · Posted Nov 27, 2019VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.