Genzyme Ireland Limited
Unit 701, Ida Industrial Park; Old Kilmeaden Road, Waterford, Ireland
FEI 3003809840DUNS 985127419
Company: Genzyme Corporation · Linked by exact D-U-N-S match (025322157) in FDA registration data
FDA has 10 inspections on file for Genzyme Ireland Limited in Waterford, Ireland (FEI 3003809840), from 2008 to 2026. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Five of the 10 FOIA requests for this site have asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, sterilization, relabeling and repacking, through Dec 31, 2026. Its registrant, Genzyme Corporation (D-U-N-S 025322157), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 10, 2008–2026
- 1 OAI · 7 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 10
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 10 requests, latest Sep 10, 2026
- Warning letters
- · CBER ↗
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Laboratory records deficient, data integrity failures
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, deficiencies in documentation and data integrity were identified in environmental monitoring and (b) (4) testing records. The records and data for these quality control activities do not demonstrate adequate integrity controls and documentation practices. A) Failing non-viable particulate testing data present in the history of (b) (4) Particle Counters is not investigated for product impact, documented as a part of the testing record, or otherwise evaluated. Instances of such findings are summarized as follows: No. Date Controlled Form Sampling Location Official Documentation Instrument Data Acceptance Criteria for ≥0.5 µm particles Discrepancy 1 3-Jan-2025 (b) (4) Action level excursion not reported 2 3-Feb-2025 Action level excursion not reported 3 18-Aug-2025 Alert level excursion not reported 4 15-Jul-2025 Alert level excursion not reported 5 13-Sep-2025 Action level excursion not reported 6 27-Nov-2025 Alert level excursion not reported *Initial, unreported result from (b) (4) testing events. Note: All particle counts are reported as particles per cubic meter (particles/m³). Examples 3-6 involved (b) (4) testing events where only the (b) (4) result was reported on the controlled form, while the (b) (4) results showing excursions were not documented in official records. B) The data present on (b) (4) Air Samplers used in active air monitoring does not support the conduct of the respective environmental monitoring, showing inconsistencies between documented sampling activities and actual instrument usage records. Examples are listed below: No. Date Controlled Form Air Samplers Used Documentation Claims Instrument Data Shows Discrepancy 1 (b) (4) Lack of accountability between active air monitor and environmental monitoring documentation 2 Lack of accountability between active air monitor and environmental monitoring documentation 3 Testing absent from instrument history 4 Testing absent from instrument history 5 Testing absent from instrument history C) Failing (b) (4) testing is not investigated. Specifically, procedure (b) (4)-SOP-0071168 titled "(b) (4) Testing" Section 5.15 reads "If the (b) (4) fails a (b) (4) refer to (b) (4)-SOP-0070985 'Deviations and Investigations', Process Engineering will raise a customer complaint. The investigation and root cause analysis along with the conclusive testing result must be referenced in the EBR." Despite the procedure, the testing history of the (b) (4) instruments indicate testing events where more than one failure was encountered, but no accompanying deviation was raised. Further, the electronic batch records fail to document the (b) (4) failures, and Altuviiio batches (b) (4) and (b) (4) have been released. These findings are tabulated below: Batch Number Product Number of Testing Failures Deviation (b) (4) Altuviio (b) (4) No Altuviio No (b) (4) Altuviio No (b) (4) Altuviio No Thymoglobulin No (b) (4) No No No No D) Official records are inconsistent with Good Documentation Practices: 1) Your firm utilizes "Review Checklist" to unofficially document findings of Quality Control document reviews. The "Review Checklist" is subsequently (b) (4) Moreover, a review of the "Review Checklist" identified entries that were made non-contemporaneously that were not attributed as such. The "Review Checklist" pertaining to December 16, 2025 reads "yes' not circled for Acceptance criteria" and "Sample results not entered." However, the corresponding record ((b) (4)-0115397) contains a circled 'yes' and incorporates the sample results without documentation that these entries are retrospective. 2) The logbooks documenting the entrance and exit times from the cleanrooms are inconsistent with the sampling times for environmental monitoring. Specifically, personnel conducting environmental monitoring are not documented as being present in the cleanroom at the times the
Shortened here; the PDF has the full text.
- Observation 2
QC procedures not followed, work orders instead deviations
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, your procedure requires a change control to be issued for implementing changes. This requirement is delineated in SOP (b) (4)-0000514 titled "Change Control Management". However, several examples were found where a Work Order was used for conducting investigations instead of following the established change control procedure. Examples include but are not limited to: A) There is no procedure to differentiate when events should be documented as a deviation or a work order. Thus, leakage events throughout your facility have been documented as work orders, without a corresponding deviation. Additionally, the work orders have not been the subject of quality oversight and the impact of the event on the facility and associated products have not been performed. Additionally, these work orders have not been trended. For example, the following leaks have been documented as work orders without a corresponding deviation: Work Order Number 3296872 Opened January 09, 2025 Description "Investigation/Actions - A water leak was identified on the (b) (4) (b) (4) On investigation it was found that the (b) (4) was found to not be (b) (4) and was leaking." Work Order Number 3296870 Opened January 09, 2025 Description "Investigation/Actions - Water was visible on the ground at the (b) (4) (b) (4) On investigation it was found that there were intermittent drops from the (b) (4) (b) (4) and the leak stopped." "Closing Comments - There was no impact on the operation of the system due to this leak and no impact on the operation of the system while repairing leak." Work Order Number 3382891 Opened August 16, 2025 Description "Water leaking from (b) (4) with no issues noted, (b) (4) closed and inspected from opposite side and no gaps appeared to be present. (b) (4) water leaked from under (b) (4) immediately. (b) (4) stopped to ensure no further water leaked out." 3384466 August 20, 2025 This work order is associated with work order 3382891 and states (b) (4) leaking" with the investigation identifying (b) (4) liquid was seen coming from (b) (4) 3301730 January 22, 2025 "Action/Investigation - leak coming for (b) (4) leak stopped." 3324758 March 21, 2025 "Investigation/Actions - Water leak on floor underneath (b) (4) identified during (b) (4) on 20 Mar 25. There was initially no sign of the source of the leak in the area at the time. Water was cleaned up and area monitored. On 21 Mar 25 water was again evident in the area. On this occasion water was seen dripping from the (b) (4) (b) (4) and the leak stopped. Residual water was cleaned up and area was monitored with no further issues." B) Your firm failed to adequately review production records to ensure that no errors have occurred or, if errors have occurred, that they have been fully investigated. There have been (b) (4) failed (b) (4) for (b) (4) (b) (4) since January 2025, attributed by your Area Engineering & Maintenance Manager to improperly (b) (4) No retrospective batch impact assessment has been conducted for these failures, and these recurring events have not been subject to deviation reporting or quality oversight review. Filling Line (b) (4) accounts for approximately 34% of these work orders. Your firm has not conducted retrospective batch impact assessments for these failures, has not subjected these recurring events to deviation reporting or quality oversight review, and has not evaluated whether (b) (4) was compromised during previous batches manufactured using the Grade (b) (4) Line (b) (4) is utilized routinely for filling of U.S. marketed products, including Thymoglobulin and Altuviiio. C) GMP Permit 240002415 was initiated for Fill Line (b) (4) under Work Order 3350858 to investigate (b) (4) functionality. The investigation was prompted by (b) (4) issues observed during the filling of a previous batch (b) (4) on Fill Line (b) (4) The investigation was conduc
Shortened here; the PDF has the full text.
Show observations 3 to 6
- Observation 3
Buildings not maintained in good repair
Buildings used in the manufacturing, processing and holding of a drug product are not maintained in a good state of repair. Specifically, the following conditions were observed in your fill/finish manufacturing areas during the current inspection: A) On January 13, 2026, in Room (b) (4) (Fill Line (b) (4)) the (b) (4) exhibited two "X" shaped cracks that were actively extruding water during the (b) (4) operations utilizing (b) (4) The intersecting cracks created four distinct arms, each measuring approximately 4 to 5 inches in length. Your firm's personnel stated they had been aware of these cracks since October 2025, yet continued manufacturing operations without adequate documentation or quality assessment of the water leak's impact on product quality. Despite awareness of (b) (4) cracks since October 2025 and ordering replacement parts in October 2025, there was an absence of GMP documentation regarding the (b) (4) condition until January 12, 2026. No quality documentation addressed the impact of active water leakage from the equipment cracks. Batch (b) (4) Thymoglobulin was being filled on January 13, 2026, when this observation was made. B) On January 12-13, 2026, in the Grade (b) (4) area (Room (b) (4)) of Fill Line (b) (4) HEPA filters supplying clean air exhibited reddish brown discoloration consistent with rust. (b) (4) particulate matter consistent with (b) (4) was observed on the Grade (b) (4) floor, and localized areas accumulated significant (b) (4) residue. Batch (b) (4) of Myozyme was being filled when this observation was made. C) During the inspectional walkthrough on January 13, 2026, we observed a section in the Grade (b) (4) Filling Line (b) (4) (Room (b) (4)) where a portion of the (b) (4) had been removed. The floor in this area exhibited visible discoloration and stains. Multiple holes remained in the floor from the removal of (b) (4) At least one of the holes contained visible blackish-brown liquid of unknown origin. Thymoglobulin batch (b) (4) was being filled in the room while this observation was made. Note: Fill lines (b) (4) and (b) (4) are routinely used for U.S. marketed drug products, including Thymoglobulin and Altuviiio.
- Observation 4
Equipment not cleaned and maintained, corrosion
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A) On January 12, 2026, filling (b) (4) used for (b) (4) contained unknown brownish white residue around the (b) (4) Internal inspection revealed brownish red discoloration consistent with rust on product contact surfaces, which your firm confirmed as "active corrosion." This (b) (4) was recently used to manufacture Myozyme batch (b) (4) This (b) (4) is used for routine manufacturing of U.S. marketed products. B) On January 12, 2026, filling (b) (4) exhibited similar internal product contact surface deterioration with brownish red discoloration and scratches/abrasions to the (b) (4) interior, confirmed by your firm as "scratches and gouges" and "active corrosion." This (b) (4) was recently used to manufacture Thymoglobulin batches (b) (4) and (b) (4) This (b) (4) is used for routine manufacturing of U.S. marketed products. C) During the filling of Thymoglobulin batch (b) (4) on January 13, 2026, a stopper was discovered on the floor beneath the (b) (4) in Room (b) (4) The stopper was located upstream from (b) (4) filling line. Manufacturing personnel indicated that the stopper could have fallen during (b) (4) operations when the (b) (4) are challenged.
- Observation 5
Failure to thoroughly review unexplained discrepancies
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A) Complaint 493112 pertaining to "Foreign Matter After Reconstitution" found in Thymoglobulin lot (b) (4) described brown particulate or blemish on the inside of the vial that was removable when wiped with a cloth. The associated Deviation WATD23E0198 documented that during inspection of Thymoglobulin batch (b) (4) vials were rejected for the (b) (4) defect of foreign matter on stopper, with (b) (4) vials classified as (b) (4) foreign matter. Your firm's engineering investigation concluded that "the most probable root cause of the Foreign Matter observed in PE 100378833 is (b) (4) as a consequence of the (b) (4) manufacturing process." Despite identifying the manufacturing process as the most probable root cause of this critical defect, your firm classified the deviation as (b) (4) and deemed the finding non-reportable. Your firm's justification that removing defective vials negated the impact of the deviation, fails to address the underlying manufacturing process deficiency that generated the foreign matter contamination. Batch (b) (4) was released to the U.S. market (Expired (b) (4)). B) Deviation WATD23E0838 documented OOS activity results of (b) (4) for batch (b) (4) at the (b) (4) Bioburden (b) (4) stage and an OOS result for PPQ batch (b) (4) at the (b) (4) (b) (4) stage. The firm's investigation concluded that sample contamination with (b) (4) during (b) (4) was the probable root cause and determined "no impact to the PPQ program." However, this conclusion was based on a hypothesis of sample contamination with (b) (4) that lacked sufficient evidence.
- Observation 6
Unjustified deviations from production procedures
Deviations from written production and process control procedures are not justified. Specifically, Batch (b) (4) of Thymoglobulin was filled under conditions that significantly deviated from qualified operating conditions within the Grade (b) (4). During inspectional walkthrough on January 13, 2026, we observed the (b) (4) and (b) (4) overflowed due to a malfunctioning (b) (4) causing (b) (4) to (b) (4) on the fill line and (b) (4) necessary for maintaining (b) (4). The blocked (b) (4) (b) (4) compromised the (b) (4) ability to maintain the required (b) (4) for Grade (b) (4) environmental classification. No deviation was raised for these non-conforming conditions, and the decision to proceed with batch filling was made under a work order without proper risk assessment of the altered environmental conditions. (b) (4) studies conducted under dynamic conditions demonstrate that these (b) (4) must remain clear of obstructions to maintain (b) (4) (b) (4) during the (b) (4) operation.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
10 requests to FDA under the Freedom of Information Act named this site, most recently on Sep 10, 2026.
Inspection ending Jan 20, 2026OAI
5 requests. In the inspection history above. FDA has posted its Form 483.
- Jun 2, 2026FDA-FOIA-2026-5471Form 483· 1 of 2 sitesRecords released
- May 11, 2026FDA-FOIA-2026-4807Form 483· 1 of 5 sitesRecords released
- Apr 1, 2026FDA-FOIA-2026-3163Form 483Records released
- Mar 12, 2026FDA-FOIA-2026-2435Form 483Records released
- Date not givenFDA-FOIA-2026-4305Form 483· 1 of 14 sitesRecords released
Inspection ending Jan 17, 2025
3 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.
- Sep 3, 2025FDA-FOIA-2025-10509Form 483· 1 of 3 sitesRecords released
- Jul 16, 2025FDA-FOIA-2025-8724Form 483· 1 of 3 sitesWithdrawn
- Jun 16, 2025FDA-FOIA-2025-7676Form 483· 1 of 10 sitesWithdrawn
Inspection date not given
2 requests.
- Sep 10, 2026FDA-FOIA-2026-8818EIROpen
- Apr 17, 2025FDA-FOIA-2025-3574Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003809840, one row per refused product line.
2 refusals from 2016-11-09 to 2025-09-03 · charged UNAPPROVED on 2 · no FDA sample analysis
FDA firm profile- 2025-09-03
DUPILUMAB58ACY02
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsF23-9339758-3/120002/1
- 2016-11-09
SEVELAMER HYDROCHLORIDE (PHOSPHATE BINDER)63LCB04
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
New Orleans District Office799-7529870-9/1/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, sterilization, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Genzyme CorporationD-U-N-S 025322157
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Genzyme Corporation (D-U-N-S 025322157) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Genzyme CorporationFramingham, Massachusetts · FEI 12204239 inspections9latestApr 9, 2026VAI1 warning letter, Jan 15, 2025
- Genzyme CorporationNorthborough, Massachusetts · FEI 30093899408 inspections8latestAug 14, 2025NAINone on file
- Genzyme FlandersGeel, Belgium · FEI 30036238399 inspections9latestSep 25, 2024VAINone on file
- SANOFI WINTHROP INDUSTRIELyon, France · FEI 30091940334 inspections4latestNov 17, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003809840 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003809840. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.