STAQ Pharma Inc
Colorado
FEI 3015144909
FDA has 4 inspections on file for STAQ Pharma Inc in Colorado (FEI 3015144909), from 2020 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 4, 2020–2026
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 4
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Facility not maintained, water intrusion above cleanrooms
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. Specifically, your firm does not maintain your facility adequately to prevent water intrusion into the mezzanine space directly above ISO-7 spaces utilized to produce injectable drug products purported to be sterile. On August 27, 2026, I observed standing water on top of non-impervious flooring within the mezzanine immediately above ISO-7 (b)(4) Laminar Airflow Production Room (Room (b)(4)), which contains an ISO-5 (b)(4) Workstation, (b)(4) Series. Subsequent inspection revealed notable staining on the back side of five (5) cleanroom tiles. This condition was present during the production of Fentanyl Hydrochloride 160 mcg/mL 50 mL Syringes, Lot 26166677A.
- Observation 2
Aseptic technique and monitoring deficiencies risk contamination
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not. Specifically, on September 1, 2026, Sterile Filling Technician [illegible] was observed in ISO-7 [illegible] Production Room 26102671A, at an ISO-5 (b)(4) Laminar Air Flow Workstation. While exchanging an environmental monitoring (EM) active air sample plate, [illegible] was observed extending her arms fully into the hood, up to her shoulders. The EM active air sample plate is positioned on a stand located above the (b)(4) IV Bag Filling and Closing Machine, greater than 12 inches from the deck of the hood, posing a risk of microbiological contamination. Additionally, the firm's personnel monitoring program includes (b)(4) sampling; however, at an action level of [illegible] Colony Forming Units (CFUs), posing a risk of environmental assurance and potentially missing sources of microbial contamination.
Show observation 3
- Observation 3
Discolored equipment not cleaned or risk-assessed
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, (b)(4) located in ISO-7 Production Room (Room (b)(4)) and ISO-7 Production Room (Room (b)(4)) exhibited visible discoloration, appearing brownish to blackish in color, on (b)(4). In Room (b)(4), (b)(4) is utilized to hold a (b)(4) bin for in-process product to be placed in prior to exiting the room. In Room [illegible], environmental monitoring equipment used during the production of drug products is placed (b)(4) of (b)(4). Cleaning of (b)(4) of (b)(4) occurs (b)(4) however, your firm has not assessed the discolorations for potential risk to cleanroom environment and product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic process validation
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A) The firm failed to recertify the ISO 5 LFH and ISO 7 (b)(4) Room after the LFH was moved from the (b)(4) to the (b)(4) in of the ISO 7 room during the Smoke Study conducted on 09/17/2020. The firm has been producing aseptically filled (b)(4) syringes from 09/17/2020 to the present with the ISO 5 LFH located on the (b)(4) of (b)(4) Room. B) The Nonviable (b)(4) and (b)(4) Viable air samplers inside the ISO 5 LFH were not in operation while conducting the Dynamic Smoke Study on 09/17/2020.
- Observation 2
Lack of environmental monitoring inside LFH
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, There is no environmental monitoring, including but not limited to, the following ancillary equipment located inside the ISO 5 Laminar Flow Hood (LFH), which is located in (b)(4) Room: A) Non-viable (b)(4) and viable (b)(4) hoses feeding into the LFH through the (b)(4) B) Power cord from (b)(4) (pump located in ISO 7) (b)(4) Room connected to the (b)(4) Electrical Outlet (inside the LFH) C) Protruding screw caps of the (b)(4) D) IV Hanging Bar and IV hooks E) (b)(4) L shaped bar that supports the Fill Bag (Fill Bag stand)
Show observation 3
- Observation 3
Failure to report compounded drugs
Your outsourcing facility did not submit a report to FDA identifying the drugs compounded during the following product reporting period as required by Section 503B(b)(2)(A) of the FD&C Act. Specifically, the following products were compounded and not identified on your report dated in: June 2021 Product Report: « Buffered Lidocaine 10 mg/mL « Desmopressin Acetate 1.5 mg/mL Nasal Spray December 2020 Product Report: « Phenylephrine 100 meg/mL « Ropivacaine HCI 2 mg/mL
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility's drug products are deficient.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Regulations FDA cited here
The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 4 inspections.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015144909 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015144909. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.