Lyophilization Services of New England, Inc.
23 Commerce Dr, Bedford, New Hampshire, United States
FEI 3008546445DUNS 081512997
FDA has 8 inspections on file for Lyophilization Services of New England, Inc. in Bedford, New Hampshire (FEI 3008546445), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Six of the eight FOIA requests for this site have asked FDA for this inspection's records.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Lyophilization Services Of New England, Inc. (LSNE) D/B/A: PCI Pharma Services (D-U-N-S 081512997).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2009–2026
- 0 OAI · 5 VAI · 3 NAI
- Inspections with 483 observations shown
- 2 of 8
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 8 requests, latest Oct 28, 2026
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterile contamination prevention procedures inadequate
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, I. Your firm failed to enact adequate production process controls for manufacturing of commercial sterile drug product. For example: a. Your firm failed to provide documented evidence to demonstrate the use of (b)(4) goggles in the Grade A and B cleanroom spaces and its potential impact in the environment from skin flora and subsequent microbial contamination risk to sterile drug products. On 06/02/2026 we observed multiple operators in room (b)(4) ((b)(4)) performing the setup for the (b)(4) for sterile drug product Lot #(b)(4), and wearing Goggles (b)(4) (b)(4) ID# 70071542560 which includes [illegible] of the goggles. (b)(4) b. A change to stop applying a sporicidal as part of the disinfection regimen for (b)(4) (b)(4) in the aseptic manufacturing area at the (b)(4) was implemented 2/5/25 without a risk assessment to evaluate the microbiological impact of the change. As part of CAPA-2024-1332, the firm stopped [applying sporicidal] onto the (b)(4) during installation and applying the sporicidal agent (b)(4) cleaning. The firm continues to use (b)(4), a non-sporicidal agent, to sanitize the (b)(4) during these steps. However, the firm does not apply any sporicidal agent to the (b)(4). Since 2/5/25, approximately [illegible] lots of the (b)(4) drug product have been manufactured on this (b)(4) line, of which approximately (b)(4) lots have been released. c. On June 02, 2026 at approximately 7:34AM, in room (b)(4) at the (b)(4) operator was observed leaning into the (b)(4) during pre-production setup. During this intervention, the operator's gown made contact with interior surfaces of the (b)(4). Although the operator performed a partial surface disinfection following the intervention, not all (b)(4) interior surfaces contacted by the operator's gown were wiped down prior to the resumption of setup activities. d. During setup of the (b)(4) assembly for (b)(4) of sterile drug product (b)(4) lot (b)(4) in ISO-5/6 Room (b)(4) Building (b)(4) on 6/2/2026, operators were observed forming the aseptic connections between Assembly (b)(4) and Assembly (b)(4) as well as between Assembly (b)(4) and the (b)(4) on the line of demarcation between ISO-5 and ISO-6. Your firm's procedures require these connections to be made within unidirectional Grade A first air from HEPA units within the Grade A area, and your firm was unable to provide evidence that Grade A first air could be maintained on the line of demarcation. e. Your firm failed to perform environmental monitoring to evaluate the risk to ISO-5 environments during critical process interventions. Specifically, during filling of drug product your firm's (b)(4) process involves opening a (b)(4) door in ISO-5/6 Room (b)(4) to load (b)(4) into the filling line hopper, exposing the Grade A (b)(4) interior to the surrounding room. Your firm does not perform environmental monitoring in the vicinity of this intervention to evaluate potential exposure of (b)(4) to contaminants and has provided no scientific justification for the absence of environmental monitoring at this location. f. Your firm failed to perform personnel monitoring in accordance with firm procedures and good manufacturing practices. For example, during setup activities for filling of sterile drug product lot (b)(4) in ISO-5/6 Room 107, Building (b)(4) on 6/2/2026, (b)(4) production operators were observed rolling only half of each finger for (b)(4). Your firm's procedures for personnel monitoring, including SOP-07509 Environmental Monitoring of the (b)(4) Aseptic Area During Processing, require operators to complete a (b)(4) for personnel monitoring. Additionally, at the conclusion of (b)(4) setup activities for (b)(4) on 6/2/2026, a QC microbiologist was observed sanitizing their (b)(4) with (b)(4) and allowing the agent to dry before immediately performing (b)(4) for pe
Shortened here; the PDF has the full text.
- Observation 2
Inadequate investigation of personnel monitoring excursions
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your firm's investigations into personnel monitoring (PM) action level excursions at failed to assess aseptic gowning practices such as the use of (b)(4) goggles as a potential root cause. Data for the facility shows action level recoveries of skin flora at the chest and/or forehead of 1 CFU/mL or more in your Grade A cleanroom spaces for approximately 90 instances from December 2024 to March 2026. Despite these action level recoveries at the chest and/or forehead in your Grade A cleanroom space, your firm reported the root causes as inconclusive and isolated incidents with no investigation into the breach in aseptic gowning. CAPA-2025-0563 was initiated on 05/05/2025 to address the increased PM recoveries at the Bedford, NH facility, however, the CAPA remains open with no documented investigation into the probable aseptic breach in gowning, nor implementation of corrective actions to address the recoveries.
Show observations 3 to 6
- Observation 3
Inadequate written production and process controls
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, procedures in support of (b)(4) drug product manufacture at (b)(4) are deficient or not available. For example: a. On 28 May 2026, observed during the (b)(4) drug product Batch (b)(4) filling process was a forceps used to remove debris from a vial (b)(4), with an (b)(4) used in the process extending over open vials, breaking first air. SOP-07637, "Aseptic Procedure for (b)(4) Aseptic Technique for Filling (b)(4)" v3.0, Effective date 14 June 2024, Section 7.4.7 indicates personnel should avoid reaching over any open or partially (b)(4) vials during aseptic production operations as much as possible, to avoid interruption of first air. The procedure fails to restrict reaching over open or partially (b)(4) vials by sanitized (b)(4) (b)(4). b. You indicate that the (b)(4) fill line (b)(4) system is (b)(4) rinsed with (b)(4) in preparation for (b)(4) sterilization. There is no procedure or training performed for the equipment rinse process. You further fail to have a procedure for the validated (b)(4) rinse of the filling pumps nor is there visual confirmation and documentation that the pumps are clean. c. SOP-07617, "Routine Environmental Monitoring of Non-Aseptic Area at (b)(4)" Revision 2, Effective date 06 November 2024 specifies for Grade C space surrounding the (b)(4) fill line (room (b)(4)), Section 7.2.3: Rooms associated with non-aseptic areas will be routinely monitored as found, Note: (b)(4) per SOP-07618. You fail to conduct environmental monitoring within Grade D and C space during manufacture, under dynamic conditions in assurance the manufacturing space is in a state of control. d. On 27 May 2026, (b)(4) personnel were gowning in Room 120-C. In a prior gowning personnel were gowning as one individual was ungowning. PQ-J0001-001, Environmental Monitoring Performance Qualification (EMPQ) of Clean Rooms at the LSNE (b)(4), issue date 28 August 2023 identifies a limit of personnel to be present in gowning (b)(4) 120-C at any given time. SOP 07593, "Gowning Procedure and Personnel Flows", Revision 6, Effective date 20 February 2026 fails to prevent the potential for contamination in personnel gowning (b)(4) 120-C by not restricting access based on the EMPQ. You failed to implement procedural controls and area signage for established room maximum occupancy limits. You further failed to implement restrictions to prevent simultaneous gowning and degowning activities. e. SOP-07593, "Gowning Procedures and Personnel Flows", Revision 6, Effective date 20 February 2026, Section 7.1.12.3 indicates to wash hands in provided sink and soap for a minimum of (b)(4), ensuring that all exposed skin on the hands is washed, followed by dry hands prior to entry into the cleanroom. The washing of hands for entry into GMP space is not conducted according to a specific process consistent with good industry practice nor is there an illustration of the hand washing process at the washing station.
- Observation 4
Equipment utilities cleaning and maintenance deficient
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, utilities in support of (b)(4) drug product are not monitored in assurance the qualified validated state is maintained. Equipment and facilities used in the manufacture of (b)(4) drug product at (b)(4) are not adequately maintained. For example: a. The (b)(4) water system used as (b)(4) water for the multiple effect still and clean (b)(4) generator fails to have water environmental monitoring testing conducted at any frequency to a specification. b. The (b)(4) distribution system used in back fill of the (b)(4) and a point of use drop at the (b)(4) fill line fails to have environmental monitoring testing conducted at any frequency to a specification. c. Observed in Grade C space surrounding the (b)(4) fill line were two wheeled carts, with the cart caster assemblies in a deteriorated state, rusty. Other carts in manufacturing space were observed with a similar attribute but to a lesser extent. d. Observed in personnel (b)(4) 165-C was a (b)(4) mounted to the wall in a deteriorated state, broken with cracks in multiple locations.
- Observation 5
Equipment design requires breaking first air
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm is unable to use some (b)(4) (b)(4) without breaking first air to open vials. For example, (b)(4) on the (b)(4) (b)(4) which your firm uses for routine interventions during the filling process for sterile drug product (b)(4), cannot be introduced into the (b)(4) environment without breaking first air to open vials post-wash and (b)(4), on the vial (b)(4) and vial (b)(4). Your firm's procedures for aseptic technique prohibit operators from breaking first air.
- Observation 6
Buildings not maintained in good repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, on 6/1/2026, a divot approximately two to four inches long was observed approximately one foot off the ground on the corner of a wall pillar in ISO-5 Room 149A Sterile Staging, Building 25 Commerce, immediately next to the exit door of the (b)(4) oven. Similarly, on 6/2/2026, a floor divot approximately one inch in diameter was observed in ISO-6 Room 108, Building (b)(4) approximately five feet from the closed (b)(4) exposing what appeared to be concrete subsurface under the cleanroom floor lining.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Eight requests to FDA under the Freedom of Information Act named this site, most recently on Oct 28, 2026.
Inspection ending Jun 10, 2026VAI
6 requests. In the inspection history above. FDA has posted its Form 483.
- Oct 28, 2026FDA-FOIA-2026-10456EIROpen
- Aug 17, 2026FDA-FOIA-2026-7922Form 483· 1 of 5 sitesRecords released
- Aug 13, 2026FDA-FOIA-2026-7866EIRRecords released
- Jul 6, 2026FDA-FOIA-2026-6382Form 483Records released
- Jun 30, 2026FDA-FOIA-2026-6212Form 483Records released
- Jun 18, 2026FDA-FOIA-2026-5943Form 483Records released
Inspection ending May 24, 2024VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 9, 2024FDA-FOIA-2024-6011Form 483· 1 of 2 sitesClosed
Inspection ending Sep 27, 2023
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Nov 7, 2023FDA-FOIA-2023-9898Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 8 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.63Equipment design, size, and location1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3008546445, one row per refused product line.
1 refusal on 2020-01-24 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2020-01-24
MISCELLANEOUS PATENT MEDICINES, ETC.66VIY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast ImportsSG5-0441027-8/21/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Lyophilization Services Of New England, Inc. (LSNE) D/B/A: PCI Pharma ServicesD-U-N-S 081512997
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Lyophilization Services of New England, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Lyophilization Services of New England, Inc.FEI 3002516348Manchester, New Hampshire, United States
Last inspected 2025-07-08NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008546445 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008546445. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.