Lyophilization Services of New England, Inc. dba PCI Pharma Services Form 483, June 2026
FDA issued this Form 483 to Lyophilization Services of New England, Inc. dba PCI Pharma Services in Bedford, New Hampshire (FEI 3008546445) at the end of a drug inspection that ended June 10, 2026. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 10, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 156 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Sterile contamination prevention procedures inadequate
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, I. Your firm failed to enact adequate production process controls for manufacturing of commercial sterile drug product. For example: a. Your firm failed to provide documented evidence to demonstrate the use of (b)(4) goggles in the Grade A and B cleanroom spaces and its potential impact in the environment from skin flora and subsequent microbial contamination risk to sterile drug products. On 06/02/2026 we observed multiple operators in room (b)(4) ((b)(4)) performing the setup for the (b)(4) for sterile drug product Lot #(b)(4), and wearing Goggles (b)(4) (b)(4) ID# 70071542560 which includes [illegible] of the goggles. (b)(4) b. A change to stop applying a sporicidal as part of the disinfection regimen for (b)(4) (b)(4) in the aseptic manufacturing area at the (b)(4) was implemented 2/5/25 without a risk assessment to evaluate the microbiological impact of the change. As part of CAPA-2024-1332, the firm stopped [applying sporicidal] onto the (b)(4) during installation and applying the sporicidal agent (b)(4) cleaning. The firm continues to use (b)(4), a non-sporicidal agent, to sanitize the (b)(4) during these steps. However, the firm does not apply any sporicidal agent to the (b)(4). Since 2/5/25, approximately [illegible] lots of the (b)(4) drug product have been manufactured on this (b)(4) line, of which approximately (b)(4) lots have been released. c. On June 02, 2026 at approximately 7:34AM, in room (b)(4) at the (b)(4) operator was observed leaning into the (b)(4) during pre-production setup. During this intervention, the operator's gown made contact with interior surfaces of the (b)(4). Although the operator performed a partial surface disinfection following the intervention, not all (b)(4) interior surfaces contacted by the operator's gown were wiped down prior to the resumption of setup activities. d. During setup of the (b)(4) assembly for (b)(4) of sterile drug product (b)(4) lot (b)(4) in ISO-5/6 Room (b)(4) Building (b)(4) on 6/2/2026, operators were observed forming the aseptic connections between Assembly (b)(4) and Assembly (b)(4) as well as between Assembly (b)(4) and the (b)(4) on the line of demarcation between ISO-5 and ISO-6. Your firm's procedures require these connections to be made within unidirectional Grade A first air from HEPA units within the Grade A area, and your firm was unable to provide evidence that Grade A first air could be maintained on the line of demarcation. e. Your firm failed to perform environmental monitoring to evaluate the risk to ISO-5 environments during critical process interventions. Specifically, during filling of drug product your firm's (b)(4) process involves opening a (b)(4) door in ISO-5/6 Room (b)(4) to load (b)(4) into the filling line hopper, exposing the Grade A (b)(4) interior to the surrounding room. Your firm does not perform environmental monitoring in the vicinity of this intervention to evaluate potential exposure of (b)(4) to contaminants and has provided no scientific justification for the absence of environmental monitoring at this location. f. Your firm failed to perform personnel monitoring in accordance with firm procedures and good manufacturing practices. For example, during setup activities for filling of sterile drug product lot (b)(4) in ISO-5/6 Room 107, Building (b)(4) on 6/2/2026, (b)(4) production operators were observed rolling only half of each finger for (b)(4). Your firm's procedures for personnel monitoring, including SOP-07509 Environmental Monitoring of the (b)(4) Aseptic Area During Processing, require operators to complete a (b)(4) for personnel monitoring. Additionally, at the conclusion of (b)(4) setup activities for (b)(4) on 6/2/2026, a QC microbiologist was observed sanitizing their (b)(4) with (b)(4) and allowing the agent to dry before immediately performing (b)(4) for pe
Shortened here; the PDF has the full text.
- 2
Inadequate investigation of personnel monitoring excursions
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your firm's investigations into personnel monitoring (PM) action level excursions at failed to assess aseptic gowning practices such as the use of (b)(4) goggles as a potential root cause. Data for the facility shows action level recoveries of skin flora at the chest and/or forehead of 1 CFU/mL or more in your Grade A cleanroom spaces for approximately 90 instances from December 2024 to March 2026. Despite these action level recoveries at the chest and/or forehead in your Grade A cleanroom space, your firm reported the root causes as inconclusive and isolated incidents with no investigation into the breach in aseptic gowning. CAPA-2025-0563 was initiated on 05/05/2025 to address the increased PM recoveries at the Bedford, NH facility, however, the CAPA remains open with no documented investigation into the probable aseptic breach in gowning, nor implementation of corrective actions to address the recoveries.
- 3
Inadequate written production and process controls
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, procedures in support of (b)(4) drug product manufacture at (b)(4) are deficient or not available. For example: a. On 28 May 2026, observed during the (b)(4) drug product Batch (b)(4) filling process was a forceps used to remove debris from a vial (b)(4), with an (b)(4) used in the process extending over open vials, breaking first air. SOP-07637, "Aseptic Procedure for (b)(4) Aseptic Technique for Filling (b)(4)" v3.0, Effective date 14 June 2024, Section 7.4.7 indicates personnel should avoid reaching over any open or partially (b)(4) vials during aseptic production operations as much as possible, to avoid interruption of first air. The procedure fails to restrict reaching over open or partially (b)(4) vials by sanitized (b)(4) (b)(4). b. You indicate that the (b)(4) fill line (b)(4) system is (b)(4) rinsed with (b)(4) in preparation for (b)(4) sterilization. There is no procedure or training performed for the equipment rinse process. You further fail to have a procedure for the validated (b)(4) rinse of the filling pumps nor is there visual confirmation and documentation that the pumps are clean. c. SOP-07617, "Routine Environmental Monitoring of Non-Aseptic Area at (b)(4)" Revision 2, Effective date 06 November 2024 specifies for Grade C space surrounding the (b)(4) fill line (room (b)(4)), Section 7.2.3: Rooms associated with non-aseptic areas will be routinely monitored as found, Note: (b)(4) per SOP-07618. You fail to conduct environmental monitoring within Grade D and C space during manufacture, under dynamic conditions in assurance the manufacturing space is in a state of control. d. On 27 May 2026, (b)(4) personnel were gowning in Room 120-C. In a prior gowning personnel were gowning as one individual was ungowning. PQ-J0001-001, Environmental Monitoring Performance Qualification (EMPQ) of Clean Rooms at the LSNE (b)(4), issue date 28 August 2023 identifies a limit of personnel to be present in gowning (b)(4) 120-C at any given time. SOP 07593, "Gowning Procedure and Personnel Flows", Revision 6, Effective date 20 February 2026 fails to prevent the potential for contamination in personnel gowning (b)(4) 120-C by not restricting access based on the EMPQ. You failed to implement procedural controls and area signage for established room maximum occupancy limits. You further failed to implement restrictions to prevent simultaneous gowning and degowning activities. e. SOP-07593, "Gowning Procedures and Personnel Flows", Revision 6, Effective date 20 February 2026, Section 7.1.12.3 indicates to wash hands in provided sink and soap for a minimum of (b)(4), ensuring that all exposed skin on the hands is washed, followed by dry hands prior to entry into the cleanroom. The washing of hands for entry into GMP space is not conducted according to a specific process consistent with good industry practice nor is there an illustration of the hand washing process at the washing station.
- 4
Equipment utilities cleaning and maintenance deficient
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, utilities in support of (b)(4) drug product are not monitored in assurance the qualified validated state is maintained. Equipment and facilities used in the manufacture of (b)(4) drug product at (b)(4) are not adequately maintained. For example: a. The (b)(4) water system used as (b)(4) water for the multiple effect still and clean (b)(4) generator fails to have water environmental monitoring testing conducted at any frequency to a specification. b. The (b)(4) distribution system used in back fill of the (b)(4) and a point of use drop at the (b)(4) fill line fails to have environmental monitoring testing conducted at any frequency to a specification. c. Observed in Grade C space surrounding the (b)(4) fill line were two wheeled carts, with the cart caster assemblies in a deteriorated state, rusty. Other carts in manufacturing space were observed with a similar attribute but to a lesser extent. d. Observed in personnel (b)(4) 165-C was a (b)(4) mounted to the wall in a deteriorated state, broken with cracks in multiple locations.
- 5
Equipment design requires breaking first air
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm is unable to use some (b)(4) (b)(4) without breaking first air to open vials. For example, (b)(4) on the (b)(4) (b)(4) which your firm uses for routine interventions during the filling process for sterile drug product (b)(4), cannot be introduced into the (b)(4) environment without breaking first air to open vials post-wash and (b)(4), on the vial (b)(4) and vial (b)(4). Your firm's procedures for aseptic technique prohibit operators from breaking first air.
- 6
Buildings not maintained in good repair
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, on 6/1/2026, a divot approximately two to four inches long was observed approximately one foot off the ground on the corner of a wall pillar in ISO-5 Room 149A Sterile Staging, Building 25 Commerce, immediately next to the exit door of the (b)(4) oven. Similarly, on 6/2/2026, a floor divot approximately one inch in diameter was observed in ISO-6 Room 108, Building (b)(4) approximately five feet from the closed (b)(4) exposing what appeared to be concrete subsurface under the cleanroom floor lining.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.