Shilpa Medicare Limited
India
FEI 3018694237DUNS 854193706
Company: SHILPA MEDICARE LIMITED · Linked by exact D-U-N-S match (858360192) in FDA registration data
FDA has 2 inspections on file for Shilpa Medicare Limited in India (FEI 3018694237), from 2024 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, SHILPA MEDICARE LIMITED (D-U-N-S 858360192), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 2, 2024–2026
- 0 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Oct 1, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate process validation procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your Process Validation (PV) for (b) (4) (b) (4) is deficient. You failed to use the (b) (4) system during in-process checks in (b) (4) stage for all strength due to lack of qualification of the system for (b) (4) product as required per Process Validation Protocol (b) (4) (# (b) (4) 044-00). According to the During (b) (4) step, the (b) (4) system is to be used to challenge for rejection (b) (4) (b) (4)
- Observation 2
Incomplete investigations for discrepancies
Written records are not always made of investigations into unexplained discrepancies. Specifically, A. On 03/01/2025 at 15:00 hour, you observed the minimum and maximum temperatures at 25.80 C and 30.40 C (Acceptance criteria: 28 C to 32 C) and the minimum and maximum relative humidity was observed at 57.30% and 79.60% RH (Acceptance criteria 70 to 80% RH) for stability chamber (#QC-E088, 30C/75%) where both humidity systems failed and lead to the chamber shutdown. Although QC notified Engineering Department and assigned Breakdown #BD/QC/25-002 to address the issues the breakdown form did not state if the chamber was loaded with stability samples, you did not perform an investigation and impact assessment for the stability samples inside the chamber, and you did not review the audit trail software (Stability Control System) for Thermolab stability chamber ID #QC-E088 to see what time the chamber actually shutdown in order to evaluate excursion time. Acceptance criteria Minimum & maximum value Temperature: 30 C (28 C to 32 C) Minimum temperature: 25.80 C Maximum temperature: 30.40 C Relative Humidity (RH): 75% (70 to 80%) Minimum RH: 57.30% Maximum RH: 79.60% The chamber was loaded with several stability samples including (b) (4) mg (US Marketed Product). On 05/27/2026, I observed stability chamber (#QC-E088, 30C/75% condition). The walls, ceiling, supply and return air covers, trays, and several stability samples were covered with mold/mildew. This chamber was loaded with several stability samples including the following listed below: Product Name Batch number Interval Sl. No. (b) (4) B. On 10/22/2025, you recorded a calibration failure in test parameter wavelength accuracy during the calibration of Agilent HPLC ID #QC-E080 where peak was not eluted in the standard (b) (4) solution. You notified your service provider on 10/28/2025 and visited your firm on 12/26/2025 for repair. You attributed the root cause to deterioration of DAD lamp and source of lens after replacing the DAD lamp and recalibrated the equipment. You then stated under impact assessment there is no impact on released product quality the calibration failure had no impact on the equipment and testing results generated on the equipment. However, you failed to conduct a thorough investigation and impact assessment on all the samples tested on the equipment since the last successful calibration to date. You have tested several samples including the following US marketed samples and (b) (4) (b) (4) on the equipment for 04/21/2025-10/16/2025 period. Date Name of the Material/Product Batch No. Test Parameter (b) (4)
Show observations 3 to 5
- Observation 3
Hold time studies not worst-case based
You established (b) (4) for Clean Hold Time (CHT) and (b) (4) Dirty Hold Time Study (DHT) for the following shared equipment (non-dedicated) that is used to manufacture (b) (4) (b) (4): (b) (4) (b) (4) which was not based on the worst-case molecules. Yet, you have not performed a Clean Hold Time (CHT) and Dirty Hold Time Study (DHT) after (b) (4) (as worst-case molecule in 2022) and (b) (4) (as worst-case molecule in 2023-2024) as required per SOP # UNIT (b) (4) PR/SOP/0017-02 "Cleaned and Dirty Equipment Hold Time," effective date 03/08/2026 as introduction of new product at the site. According to your Production Manager (b) (6) and Sr. Manager QA (b) (6), (b) (4) is considered the worst-case molecule at the site.
- Observation 4
Incomplete batch packing reject reconciliation
Production records do not contain complete information relating to the production and control of each batch. You failed to document in your batch packing record (BPR # for (b) (4) (b) (4) (b) (4) the total number of rejects (b) (4) collected from the system and checkweigher rejected, and the number of rejects actually (b) (4) (b) (4) displayed from the system and the checkweigher display for reconciliation. In addition, when (b) (4) collected rejects from the checkweigher, you do not perform a physical count of each rejected of (b) (4) for under count and over count. (b) (4) There are no controls in place to prevent unauthorized access to rejected for system and (b) (4) (b) (4) checkweigher. Although these rejected are locked, rejected can be physically removed (b) (4) (b) (4) without unlocking the (b) (4)
- Observation 5
Inadequate controls over computerized systems
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Per your Production Manager (b) (6) your firm does not review data, audit trails and alarm reports generated by the HMIs (GT-2708) and SCADA of your non-dedicated equipment ID #PR-E016) (b) (4) and (ID #MB-E030) utilized in the Micro Lab. Alarms generated for the (Production) (b) (4) (b) (4) and (Micro) including sterilization load cycles are not backed up and automatically overwritten (b) (4) by the system.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Calibration/Inspection/Checking not done
Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 1, 2026. Each one asked for a Form 483.
Inspection ending May 29, 2026Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Oct 1, 2026FDA-FOIA-2026-9545Form 483Records released
- Jul 27, 2026FDA-FOIA-2026-7173Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- SHILPA MEDICARE LIMITEDD-U-N-S 858360192
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names SHILPA MEDICARE LIMITED (D-U-N-S 858360192) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- SHILPA MEDICARE LIMITEDIndia · FEI 30098764307 inspections7latestNov 21, 20251 warning letter, Oct 9, 2020
- SHILPA MEDICARE LIMITEDHyderabad, India · FEI 30197734581 inspection1latestMar 10, 2023VAINone on file
- SHILPA MEDICARE LIMITEDBengaluru, India · FEI 30106194011 inspection1latestFeb 13, 2019VAINone on file
- SHILPA BIOLOGICALS PRIVATE LIMITEDKarnataka, India · FEI 3022989727Registered; no FDA inspection on file
Other FEIs recorded as Shilpa Medicare Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Shilpa Medicare LimitedFEI 3030542761Hyderbad, India
Last inspected 2024-03-01NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3018694237 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3018694237. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.