Shilpa Medicare Limited Form 483, May 2026
FDA issued this Form 483 to Shilpa Medicare Limited in India (FEI 3018694237) at the end of an inspection that ended May 29, 2026. It lists 5 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 29, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Oct 22, 2026
- 146 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate process validation procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your Process Validation (PV) for (b) (4) (b) (4) is deficient. You failed to use the (b) (4) system during in-process checks in (b) (4) stage for all strength due to lack of qualification of the system for (b) (4) product as required per Process Validation Protocol (b) (4) (# (b) (4) 044-00). According to the During (b) (4) step, the (b) (4) system is to be used to challenge for rejection (b) (4) (b) (4)
- 2
Incomplete investigations for discrepancies
Written records are not always made of investigations into unexplained discrepancies. Specifically, A. On 03/01/2025 at 15:00 hour, you observed the minimum and maximum temperatures at 25.80 C and 30.40 C (Acceptance criteria: 28 C to 32 C) and the minimum and maximum relative humidity was observed at 57.30% and 79.60% RH (Acceptance criteria 70 to 80% RH) for stability chamber (#QC-E088, 30C/75%) where both humidity systems failed and lead to the chamber shutdown. Although QC notified Engineering Department and assigned Breakdown #BD/QC/25-002 to address the issues the breakdown form did not state if the chamber was loaded with stability samples, you did not perform an investigation and impact assessment for the stability samples inside the chamber, and you did not review the audit trail software (Stability Control System) for Thermolab stability chamber ID #QC-E088 to see what time the chamber actually shutdown in order to evaluate excursion time. Acceptance criteria Minimum & maximum value Temperature: 30 C (28 C to 32 C) Minimum temperature: 25.80 C Maximum temperature: 30.40 C Relative Humidity (RH): 75% (70 to 80%) Minimum RH: 57.30% Maximum RH: 79.60% The chamber was loaded with several stability samples including (b) (4) mg (US Marketed Product). On 05/27/2026, I observed stability chamber (#QC-E088, 30C/75% condition). The walls, ceiling, supply and return air covers, trays, and several stability samples were covered with mold/mildew. This chamber was loaded with several stability samples including the following listed below: Product Name Batch number Interval Sl. No. (b) (4) B. On 10/22/2025, you recorded a calibration failure in test parameter wavelength accuracy during the calibration of Agilent HPLC ID #QC-E080 where peak was not eluted in the standard (b) (4) solution. You notified your service provider on 10/28/2025 and visited your firm on 12/26/2025 for repair. You attributed the root cause to deterioration of DAD lamp and source of lens after replacing the DAD lamp and recalibrated the equipment. You then stated under impact assessment there is no impact on released product quality the calibration failure had no impact on the equipment and testing results generated on the equipment. However, you failed to conduct a thorough investigation and impact assessment on all the samples tested on the equipment since the last successful calibration to date. You have tested several samples including the following US marketed samples and (b) (4) (b) (4) on the equipment for 04/21/2025-10/16/2025 period. Date Name of the Material/Product Batch No. Test Parameter (b) (4)
- 3
Hold time studies not worst-case based
You established (b) (4) for Clean Hold Time (CHT) and (b) (4) Dirty Hold Time Study (DHT) for the following shared equipment (non-dedicated) that is used to manufacture (b) (4) (b) (4): (b) (4) (b) (4) which was not based on the worst-case molecules. Yet, you have not performed a Clean Hold Time (CHT) and Dirty Hold Time Study (DHT) after (b) (4) (as worst-case molecule in 2022) and (b) (4) (as worst-case molecule in 2023-2024) as required per SOP # UNIT (b) (4) PR/SOP/0017-02 "Cleaned and Dirty Equipment Hold Time," effective date 03/08/2026 as introduction of new product at the site. According to your Production Manager (b) (6) and Sr. Manager QA (b) (6), (b) (4) is considered the worst-case molecule at the site.
- 4
Incomplete batch packing reject reconciliation
Production records do not contain complete information relating to the production and control of each batch. You failed to document in your batch packing record (BPR # for (b) (4) (b) (4) (b) (4) the total number of rejects (b) (4) collected from the system and checkweigher rejected, and the number of rejects actually (b) (4) (b) (4) displayed from the system and the checkweigher display for reconciliation. In addition, when (b) (4) collected rejects from the checkweigher, you do not perform a physical count of each rejected of (b) (4) for under count and over count. (b) (4) There are no controls in place to prevent unauthorized access to rejected for system and (b) (4) (b) (4) checkweigher. Although these rejected are locked, rejected can be physically removed (b) (4) (b) (4) without unlocking the (b) (4)
- 5
Inadequate controls over computerized systems
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Per your Production Manager (b) (6) your firm does not review data, audit trails and alarm reports generated by the HMIs (GT-2708) and SCADA of your non-dedicated equipment ID #PR-E016) (b) (4) and (ID #MB-E030) utilized in the Micro Lab. Alarms generated for the (Production) (b) (4) (b) (4) and (Micro) including sterilization load cycles are not backed up and automatically overwritten (b) (4) by the system.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.