Skip to content

Shilpa Medicare Limited

India

FEI 3009876430DUNS 650644136

Company: SHILPA MEDICARE LIMITED · Linked by exact D-U-N-S match (858360192) in FDA registration data

FDA has 7 inspections on file for Shilpa Medicare Limited in India (FEI 3009876430), from 2015 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Feb 25, 2020. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, SHILPA MEDICARE LIMITED (D-U-N-S 858360192), has registered 4 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
7, 2015–2025
1 OAI · 3 VAI · 2 NAI
Inspections with 483 observations shown
4 of 7
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Dec 4, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic/sterilization validation

      OBSERVATION 1 Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic and sterilization process. Specifically, A. Your firm's qualification of airflow in [redacted] airflow, contamination risk, and aseptic processing line suitability due to the smoke studies being performed using a [redacted]. This smoke is not neutrally buoyant, potentially masking the true airflow pattern and making it difficult to identify issues like recirculation. Additionally, the following discrepancies were noted: 1. Turbulence ~ (6)(4) 1 (Pushing • Addition • Addition • (Removal • (Removal • Removal • ~ achine setup) • .(Removal 2. Not all activities are represented a. The equipment (b)< >demonstrating setup activities for the filling line. Removal of this (bH>) studies not being re5 . (bH>) equipment b. The smoke studies videos did not demonstrate dissemination of the sterile equipment and the placement of forceps and scissors throughout the line. c. Not all environmental monitoring activities are demonstrated. The following locations were not executed during the smoke studies: (b,C4) • Microbial monitoring • Microbial monitoring 3. The amount of smoke is not adequate to evaluate activities in the following videos: • (b)(4) Addition • :(Removal (b)(4) ----, • (vial withdrawn) (b)(4) • (Removal • (Removal • (Machine setup) 4. The nozzles on the wand used to distribute smoke in the following smoke studies were observed pointing downwards. This is significant as it is unclear whether the airflow being evaluated or due to the velocity of the smoke leaving the wand. • (b)(4) (Sample taken from • (b)(4) Microbiological monitoring 5. The angle of the following video recordings does not include the full range for example, from the [redacted] of the [redacted] • (bH>) (Addition B. Your firm's written procedure for requalification does not ensure consistent replication of worst-case challenge conditions during requalification, and the challenge testing practice fails to simulate actual use conditions. 1. Your firm's performance qualification protocol (Doc# SMLJ/QAD/SOP-GEN/F01-01) lacks specific biological indicator placement guidance. BIs should be placed "inside" the exact worst-case location or [redacted]. 2. Your firm lacks written procedures for BI placement in challenging configurations. Operators place BIs inside [redacted]. Additional [redacted] sterilization, invalidating the challenge test and failing to demonstrate sterilization efficacy under actual use conditions. Your firm's load pattern documentation lacks adequate detail for article orientation. For example the "Filling; cfd [redacted] CPS(6~025) shows (b)() whether scissors should be loaded open or closed, which affects sterilization efficacy. C. The aseptic process simulation procedure states qualified personnel will perform intervention during mediafill. The Entry and Exit Procedures for Vial Filling Areas procedures states, "Only authorized personnel (Trained, qualified and certified) are allowed to enter the Vial filling area. However, it is to ensure that personnel should participate in media fill". There is no definition of activities to be performed by the operator to be trained, qualified and certified. Total Employee (b)(6) participated in [redacted] prior to participating in a [redacted] was not included as an acceptance criterion, and the delay in all [redacted] was not included. The negative impact on the [redacted] for drug products. (b)(4) of [redacted] injection. E. Sterilization for the manufacture of (b)() injection [redacted] Sep. 2024 requalification failed to demonstrate the [redacted]. (CD placements represent the most challenging locations.) 1. No risk assessment could be provided to show the [redacted] of [redacted] decontamination of the [redacted]. b. We observed equipment parts touching [redacted] bags. We also observed [redacted] assembled on the [redacted] tank, sitting on bottom surface with no assurance that

      Shortened here; the PDF has the full text.

    2. Observation 2

      Deficient visual inspection program

      OBSERVATION 2 Procedures designed to prevent microbiological contamination are not established and followed. Specifically, A. The visual inspection program for sterile products is deficient. For example: 1. The visual inspection kits and procedure used for products, including (b)(<) inspectors to detect defects: a. There is no justification for the inspection kits (including the selection within the kits) and the exclusion criteria for defects or their severity. (b)(4) Injection (b)(4) b. The number corresponding to the vial used on the top of the vial with [redacted] is not easily identifiable under regular light, including (b)(4) mL and (b)(4) mL, and via [redacted]. c. The selected defects within the kits are not representative. Defects within the [redacted] (6)(__) defects (including glass particles) are not in the same order for at least [b](<). Good vials within the (bH>) mL your personnel would have been rejected in a normal run. d. The qualification of the visual inspectors does not require the visual inspector to document the defect identified during the qualification and will document on a checklist the false negative, or true negative. 2. The process for examining [redacted] does not ensure that visible article defects are detected. During inspection of (6)(4) mg/mL on 17 Nov 2025 we (JAP and YK) observed (and 1 visual inspector subsequently) that one of the (b)(<) vials had an apparent white fiber, however both visual inspectors performing the inspection previously identified this vial as not having a defect. In addition, on 18 Nov 2025 (bH>) (JAP and YK) observed (and 2 visual inspectors subsequently) additional vials had an apparent white fiber, however the visual inspectors previously identified these vials as not having defects. 3. The following additional deficiencies were identified with the visual inspection process: a. The library of defects or procedure does not include or describe a [redacted] defects, including (b)< >. The procedure does not describe the proper appearance of defects and does not provide instructions for comparing the product to the reference for visual inspection. b. To date, particle, fiber, or other defects that are always categorized as major defects have not been characterized or identified as extrinsic and intrinsic. c. During the visual inspection [6><] the location for each vial selected is not documented. During inspection on 17 Nov 2025 the visual inspector did not document the tubes used during the [redacted] inspection. It was not documented that this was performed. d. Light intensity of the visual inspection booths. During the inspection, we (JAP and YK) marked visual inspection areas that did not meet the light intensity acceptance criterion per procedure. Furthermore, visual inspection activities in the areas where light intensities were observed outside the limit were not stopped. In addition, all inspection booth lights are turned off during breaks and not reverified once the break is completed before resuming visual inspection activities. B. Fallen vial interventions are grouped together by common intervention names and performed in different locations making it difficult to get meaningful information out of the tracking of interventions. Additionally, interventions which occur during commercial manufacturing are not tracked or trended per container size. Instead, [redacted] mL and [redacted] mL sizes are grouped together resulting in changes occurring without container size not being detected.

    Show observations 3 to 8
    1. Observation 3

      Aseptic area cleanliness deficiencies

      OBSERVATION 3 Aseptic processing areas are deficient regarding the system to produce aseptic conditions. Specifically, [redacted] used in the manufacture of [redacted] composed of smooth and cleanable surfaces. During review the following was observed: A. [CbH>] water used during cleaning. The inside of these [redacted] contain material supporting microbial growth. B. The manufacturer of the (6H~) [redacted] integrates the machines; the material is not easily cleanable and appears to be flaking. C. A mast-like substance by the [redacted] with chipping/flaking of [redacted] caulking, and blue/black electrical tape was observed inside [redacted]. D. A fiber was observed hanging from [redacted]. Dings/dents in the [redacted] residue was also observed (b)(4) on [redacted]. E. [redacted] stoppers transfer to stopper bowl. F. [redacted] G. The [Cb>...] by the [redacted] the stopper bowl upon [redacted] of [redacted] stoppers. H. The NVP probes used inside the [redacted] covers after [redacted] potentially leaking. I. During the observation of cleaning activities performed on [redacted] was noted: 1. Production Supervisor documented "complies" for the dismantling of [redacted] bowl, (b)(4) at 11:38 am. At the time of his signature, the [redacted] was not fully dismantled and would not be removed until after [redacted]. The exact dismantling sequence was not documented. Additionally, the times and personnel involved in the breakdown and the personnel involved were not documented. 2. After spraying the inside of the [redacted] equipment with a dry lint free cloth. While watching cleaning activities we observed the operator obtaining a stool so he could reach the back wall. J. There are no spray guns used in the spraying of [redacted] the (bH>) making it difficult to clean all internal surfaces. K. During the walk-through inspection the (b)(>) hoses were observed to be discolored. Management could not provide documentation for when the last time the hoses were changed. The spray gun tube was found damaged/leaking. This procedure is not being followed. While watching cleaning the hoses leaked, one due to cracking. L. Missing screws on the [redacted] clean (bH>) the (bH>)

    2. Observation 4

      Deficient area controls and NVP monitoring

      OBSERVATION 4 The separate or defined areas and control systems necessary to produce aseptic conditions are deficient. Specifically, A. Non-viable particle (NVP) monitoring is not scientifically justified. For example, 1. The location of NVP counters within line areas where critical activities are occurring (e.g. in the stopper addition and in-process [redacted] areas) nor are there counters placed to monitor during the study and no existing probe is present in the area (e.g. under the [redacted] area at [redacted] location: [redacted] in [redacted]). 2. There is no impact assessment conducted nor specification limit for Class 100 areas is exceeded at any time during manufacturing nor actions established with respective limits for [redacted] μm particles/ft3 and [redacted] μm particles/ft3. However, during the manufacturing [redacted] mg/vial Batch [redacted] the [redacted] area where particle counts were obtained at [redacted] particles/ft3. Empty vials were present during the excursion. No impact assessment was initiated nor any corrective actions documented. B. Non-viable particle counter (NVPC) tube lengths in your system exceed the isokinetic probe meter without evaluation of particle loss. During the IQ/OQs, tubing, and not the height of the probe was considered. The isokinetic probe met the NMT (b)(4) [redacted]. C. Your firm's Line I [redacted] gasket where portion of the gasket was modified with sealant and repair. Your firm could not provide a document to demonstrate what risk assessment was performed before the modification, and what appropriate qualification was done to ensure that the modification will not affect the quality or sterility. Your firm could not provide documentation to show what [redacted] the Line I [redacted].

    3. Observation 5

      Inadequate review of discrepancies and deviations

      OBSERVATION 5 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch and its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. During the manufacture of (b)(<) [redacted] (bH>) [redacted] alarms were identified within the [redacted]. An impact assessment form completed for these excursions stated no impact on product quality as these [redacted] alarms were documented. The impact assessment is deficient since at least 5 alarms were observed for over one minute (including an alarm up to 26 minutes). There is no assessment of the process and addition, root causes including (b)l were not completed. B. During the [redacted] the particle excursions over [redacted] locations (including [redacted]) exceeded the specification limit of not more than (bH>) and no impact assessment was initiated. The root causes identified for the alarms included movement within the (bH>) fluctuations in (b)<> during filling and sealing. Historical data reviewed did not show this level of alarms, including during identified interventions or sealing activities. The impact assessment stated that there were vials present were in stored condition. However areas such as the [redacted] were not assessed. Furthermore, the assessment was not contributory to 14 of the 39 alarms. C. SML?-005-24-005 was initiated on 0 [redacted] Related Substance by HPLC testing for the impurity in [redacted] injection [redacted] mg vial. Batch [redacted] the cause was related to the two deviations of (bH>) [redacted] vials to the [redacted] during (b)< > step that occurred during the manufacture of the batch. Samples were pulled as required by the deviations, which concluded this impurity was within the specification limit (stating there was no impact to product quality) and attributed the identified root causes as related to the deviations. Although the batch was subsequently rejected, the root cause identified and subsequent corrective actions do not ensure that there is adequate control of this impurity formation during the manufacturing process to prevent recurrence. D. SJL/OOS/25/001 was initiated on 14 May 2025 due to [redacted] for (bR) Tablets [redacted] specification of [redacted] % to [redacted] %. The [redacted] to collecting a sample of the [redacted] The subsequent [redacted] sampling produced a passing result. There was no assessment of the [redacted], concealing the ultimate root cause for the [redacted]. There is no scientific to support that the results from the original sample were representative. E. During the observation of cleaning activities performed on [redacted] the Production Supervisor documenting [redacted] bowl, cut and [redacted] not yet been performed. Management considered the pre cleaning check list as the equipment first needs to be [redacted] any braces of the [redacted] during they [redacted] of this equipment during pre cleaning even though the pre-cleaning practice for the supervisors working on [redacted] was not followed. Although this data integrity discrepancy became known during [redacted] an investigation was initiated to determine the scope of [redacted] due to inaccurate forms. F. Inspection (b)(4) mg/vial batch record states data could not be provided for exceeding [redacted]. Whether the [redacted] is maintained on [redacted] monitors the [redacted] bottle but no action is taken when the ((b)(4) (b)(4)) for example, injection-1 [redacted]. G. Deviations are not initiated for critical alarms, including testing for [redacted] and NVP excursions for individual batches. These impact assessments are not tracked, trended, or have thorough root cause evaluation or corrective actions. The following number of impact assessment forms were issued in 2024 and 2025: Form name Impact Assessment Sheet for Interventions exceeding Maximum Allowable Limit/Longest Duration Allowed/Maximum Persons Allowed to Perform the Intervention Evaluation Repor

      Shortened here; the PDF has the full text.

    4. Observation 6

      Poor equipment cleaning and maintenance

      OBSERVATION 6 Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity. Specifically, A. Equipment used in the manufacture of [redacted]. For example, during the walkthrough the following: 1. Inspection of [Cb><>] observed residue on the interior of the [redacted] duct of [CbH>] for [redacted] ppm and criteria of not more than [bX] ppm. This [redacted] validation [Cb><>] cleaning cycle after processing for (b)(4). 2. Inspection of the SM [redacted] observed on the [Cb><>] apparent [redacted] (b)(4) and an apparent leak from the [redacted] following [CbH>] Tablets [redacted] mg Batch [redacted]. 3. [CbH>] Machine SM attachment connecting the [redacted] [Cb><>] tape located within the product pathway. According to your production personnel, this was added by the operations staff as a temporary attachment. However, there was no procedural requirement nor supporting documentation provided to support the use of this material for the [redacted] attachment. B. The cleaning program for the validation is deficient. 1. Rinse samples are collected from the [redacted] validation. However, the total volume used for the rinse is not documented to ensure the maximum allowable carryover is measured. 2. The swab locations chosen for cleaning validation are not scientifically justified or adequately assessed. For example, the swab locations SMLJ [Cb><4] 120 on Line I did not consider locations such as the [redacted] in its assessment nor are there studies performed which support the ability to clean areas. C. Magnehelic gauges for differential pressures with alarms are not continuously monitored to ensure proper pressures. During [redacted] injection (bH>) mg/vial Batch (bH>) differential pressures below the specified limits were recorded. Differential pressures are not continuously monitored at the (b)(>) of [redacted]. Issues identified by production personnel during the manufacturing were recorded as fixed, without documenting the differential pressure history.

    5. Observation 7

      Deficient laboratory method validation

      OBSERVATION 7 Laboratory controls do not include the establishment of adequate specifications and test procedures designed to assure that components, drug products, and containers meet appropriate standards of identity, strength, quality and purity. Specifically, A. Your firm failed to provide complete method validation documentation for an analytical test method to the compendial method for (b)(4). Your firm only provided [redacted] (Doc# SML7[Cb><'7AMV1REPORT/) performed by your contracting laboratory who does product release testing. This is a failure to perform the compendial method and to demonstrate non-inferiority of your in-house method compared to the compendial method. B. Your firm's method equivalency reports do not demonstrate non-inferiority of your in-house test method. 1. The Analytical Method Equivalency Report (Doc# AFD/MESCb>C/AS/004) by HPLC compares the in-house method and the compendial method but does not provide each method's data. Your firm failed to calculate an overall RSD value. Calculating RSD is not a sufficient statistical test for method comparison. Your report does not demonstrate that your in-house method performs equivalently to the compendial method. 2. The Analytical Method Equivalency Report for [redacted] Capsule [redacted] mg and [redacted] mg (Doc# SMLJ/QCD/REP-MIS/0012-00), your firm provided assays using both in house method and the compendial method. But your firm did not conduct any statistical testing to demonstrate the in-house method performs equivalently to or better than the compendial method. There were different testing parameters for compendial method and there is no scientific justifications to support the parameter adjustments. C. Your firm's method validation transfer methods are deficient. Your firm performed analytical method transfer validation for Related Substance Method [redacted] Injection [redacted] mg/vial by HPLC from Unit [redacted] to SMLJ7AMT [redacted] SML/Rt6 [redacted]. Data obtained at receiving laboratory should have quantitative acceptance criteria. There were no scientific, quantitative acceptance criteria to demonstrate that the receiving laboratory can perform the test method the same as the origin laboratory. D. The sample size of m ml for [Cb><>] is not appropriate to derive a statistically valid number [redacted]. Microbial results from samples taken during this time show [redacted] % (b)(ii) CFU/ml from [redacted] sterile [redacted] products.

    6. Observation 8

      Unreliable stability program and reporting

      OBSERVATION 8 The written stability program for drug products does not include reliable, meaningful, and specific test methods. Specifically, A. Your firm failed to include all relevant test results and data in the report. Your Method Validation Report of Related Substance for [redacted] AFD/AMV1 (bH=1FP/RS/098R) includes forced degradation test. Your firm performed stress tests and obtained two results within the expected degradation level, yet only the data with the highest mass balance result was reported on the report. B. Your firm failed to ensure that your contracting laboratory, which is responsible for product release testing, maintained analytical method validation and specifications. Your contracting laboratory (Shilpa Medicare Limited Unit) standard operating procedure for Analytical Method Validation (SML7[>]-7 SOP/0026-05) does not include necessary oversight. However, neither your contracting laboratory nor the firm provided documented existing analytical methods to ensure continued suitability for the following: Analytical Method Validation Report • [redacted] mg/vial (Doc# AFD/AMV1...) • Analytical Method Validation Report [redacted] mg & [redacted] mg (Doc# AFD/AMV...) DATES OF INSPECTION 11/10/2025 (Mon), 11/11/2025 (Tue), 11/12/2025 (Wed), 11/15/2025 (Mon), 11/16/2025 (Tue), 11/17/2025 (Wed),

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Quality unit failures and data issues

      OBSERVATION 1 A. Your Quality Unit failed to ensure that all production requirements. Your Quality Unit has not performed the objectionable practices observed and do not negatively affect products. Moreover, many of the objectionable conditions noted below necessary skillsets training, experience and/or scientific manufacturing processes and related systems in order to • All the complaints received since 2017 to present for sterile "minor"; • No CAPAs have implemented to decrease re-occurrence • All the QC Laboratory (Chemical Micro) incidents (Un-planned) been classified as "minor": • There is a practice of invalidating failing or OOS results • The implemented procedure for in-process sampling is; • There is no assurance that your process simulation studies conditions observed and/or that might occur during routine B. No CAPA has been identified/implemented for the repetitive defects observed in vials of (b)(4). Your firm has failed to thoroughly evaluate in combination complaints received (approximately (11) confirmed complaints) defects in vials of (b)(4) drug product. C. Your firm failed to conduct a thoroughly trend analysis for products manufactured at Shilpa site. Specifically, your Quality Control Unit has been releasing lots out of the specification during In-process and release testing. The manufacturing process is not sufficiently robust and reproducible. For example, the decreasing mg/ vial listed product details: Lot Batch # (b)(4) mg/vial: Batch # (b)(4) was released to USA market (b)(4) mg/vial: Batch # (b)(4) was released to USA market (b)(4) mg/vial: Batch # (b)(4) was released to USA market None of these released lots were included into your stability drug product until expiry.

    2. Observation 3

      Missing written production/process procedures

      OBSERVATION 3 There are no written procedures for production and process [controls] that define the identity, strength, quality, and purity they purport or Specifically, your Quality Unit approved for instrumentation, completing the validation process and characterizing the empirical data (e.g., penetrability and fragmentation testing). Out-of-Specification Report SJ OOS r18/02 was initiated 16 (date). First validation for Expiration Date 02/2020. OOS results in assay testing by HPLC. Your QC laboratory performed solution and reanalysis with fresh sample preparations; confirming OOS results. Manufacturing investigation was also carried out. No definite root cause of the OOS results; the following CAPAs were proposed: (b)(4).

    Show observations 4 to 15
    1. Observation 4

      Inadequate laboratory control procedures

      OBSERVATION 4 Laboratory controls do not include the establishment of [procedures] designed to assure that drug products conform to appropriate specifications. Specifically, your Quality Control Unit (QCU) failed to design test procedures designed to assure that representative samples are taken for analysis (e.g., finished product) during filling process. Your current analytical procedures in the assay HPLC report S.J.A.VIV (b)(4) FPJ/FS/026R-RO; effective content in (b)(4) injection 1.0 / 2.1 vial drug product. The control procedure 'Finished Products' Rev 06 and assay dilution methods are not documenting representative sampling for the filling process.

    2. Observation 5

      Aseptic process simulation deficiencies

      OBSERVATION 5 Procedures designed to prevent microbiological contamination are not established or followed. There is no assurance that your process simulation studies designed to assure aseptic operations are representative during routine aseptic filling operations of vials. For example, the media fill batch records for (b)(4) filling do not describe in detail how the non-routine interventions, engineering personnel during process simulation. This mechanical process or no scientific rationale of interventions. The intervention is allowed for line. The same intervention these two instances three (3) operators were working simultaneously. This non-routine intervention is reported as 'Repairs by maintaining personnel'. There is no assurance that equipment adjustments, mechanical interventions, or commercial lancing activities are accurately documented. The practice of reporting mechanical interventions as 'Repairs by maintaining personnel' and intervention is simulated during the process simulation. This product was filled in the (b)(4) inc ase ... (interrupted text). Some witnessed breaches in aseptic filling process.

    3. Observation 6

      Non-representative sampling of batches

      OBSERVATION 6 Drug product samples are not representative of the entire batch. A. Your control procedure SOP QADGEN-011-06 entitled "Sampling or In-process and Finished Products" Rev. 03 does not require the sampling of vials between the batch to ensure that representative samples for the entire batch are always collected. The procedure does not require sampling of vials between the batch to ensure representative samples for the entire batch are collected. B. Your Quality Unit failed to accurately collect the proper analyses (e.g., assay, CV and Dissolution, among others). Example of discrepancy is illustrated in the table below: Current Quantity vials for sent to Quantity of lots Product Q Laboratory for Required Release. *Addition of the CU and Dissolution samples missing. **Addition ***Not considering there-tests samples. Note: The minimum amount does not consider the extra. This small/unequal sampling process also impacts the long-term ... re-test and stability chamber samples. Therefore re-test and additional samples from stability chambers are not considered.

    4. Observation 9

      Chromatography and data handling failures

      OBSERVATION 9 Testing and release of drug products for distribution do not ensure satisfactory conformance to the final specification prior to release. Specifically, your Quality Assurance and/or Quality Control which involves chromatographic data (i.e., HPLC, GC, throughout a chromatogram) accuracy and systems suitability are not always established and/or properly performed. 1. The reproducibility tests (i.e., relative standard deviation or RSD) are not calculated for the entire run as allowed under procedure SOP QCD GEN 02-1-17 entitled "Chromatographic Data". However, QCs do not calculate the run R'sD for the entire run. 2. The control procedure SOP QCD GEN 02-1-17 allows to use different processing methods (i.e., sequence chromatographic data run). For example the method ... the systems suitability standard under 'Method' practice conforms ... used for the control standard under method. 3. Your QC laboratory failed to follow the control procedure 'Chromatographic Data Station' Rev 17 in that it specifies after the detector not being 'ON' it is necessary to perform manual integrations in those cases in which the peaks in the chromatogram affect the detector. For example, Unplanned Deviation # UP-QCD-18-033 in-process injection for (b)(4) injection for (b)(4) mg/vial, Batch (b)(4) sequence IP-180013_AB_001 being run in HPLC System during sample injection #3 (i.e., Blank, ... ) the sequence was interrupted due to UPS battery back-up failure. The UPS battery failed and the HPLC system sequencer run was re-initialized after a delay of approximately (b)(4) and Sample Test Standard were performed. The sequence was restarted. However, your QC unit failed to affect standard bracket, including the sample affected standard bracket.

    5. Observation 15

      Reserve sample handling and inspection lapses

      OBSERVATION 15 Reserve samples are not always handled appropriately and inspection is not performed. There is no assurance that representative samples of (b)(4) are retained for evidence of deterioration. Specifically the reserve sample procedure does not detail the number of sample containers/bottles that were the finished products, components (e.g., package integrity, number expiration among others). In addition, the control 'Management of Reserve Samples' Rev 05 does not provide detail for examination.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Instruments, apparatus, et. al. not meeting specs

      The use of instruments and apparatus not meeting established specifications was observed.

    2. Written program not followed

      The written stability testing program is not followed.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate product hold-time/labeling

      Injection ®® mg/vial is labeled with “The®® product may be kept in the vial or drawn into a ®® sr. When®® injection ® mg/vial is [illegible] using®® that has not been [illegible] the®® product may be held under conditions** for up to ®®. When injection ®® mg/vial is [illegible] using ®® the product may be stored under ®® conditions** for up to ®®. [Illegible] with [illegible] for®® administration may be stored for up to [illegible] between 2°C and 8°C**; when [illegible] it may be stored for between 2°C and 8°C”. Review of the data generated from the hold time study shows that the product would fail: • For 2 impurity when®® with [illegible] at room temp and held for ®% • For 2 impurity and assay when ®® within 2-8°C and stored at 2-8°C for [illegible]

    2. Observation 2

      Unjustified commercial specifications

      Scientific rational could not be provided for the following commercial product specifications: A. Release specification for Injection ®® mg/vial is set at not less than ®% and not more than ®% of label claim while the shelf life specifications are set at not less than ®% and not more than ®% of label claim. B. Injection ®® mg/vial can be diluted with mL for ®® injection or [illegible] injection. No impurity specifications are listed for release and shelf life testing specifications for the [illegible] product. Instead the impurity specifications are listed as “For information”.

    Show observations 3 to 10
    1. Observation 3

      Insufficient cleaning/maintenance procedures

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. A. Cleaning validation for each product determined how many times the operators need to repeat the cleaning procedure prior to it removing the residue left from the previous batch. This could range from [illegible] times. Operators do not document the number of times cleaning was repeated. The cleaning procedure does not specify whether [illegible] should be used and only states “if required, rub with [illegible]”. The operators do not document the use of the [illegible]. B. There is no cleaning procedure or cleaning validation for the ®@. C. How to collect the rinse sample following manual cleaning is not specified in a procedure.

    2. Observation 4

      Inadequate OOS and complaint investigations

      Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed. Specifically, A. Your firm did not initiate an investigation into repetitive complaints received regarding [illegible] Injection appearance of ®@ product. All investigations concluded the complaint batch/product is acceptable toward product quality perspective. B. Your firm invalidated initial out-of-specification (OOS) laboratory results in favor of passing results without an adequate investigation.

    3. Observation 5

      Aseptic process and microbiology controls deficient

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. A. During the watching of ®@ injection production on 21 Nov. 2017, I noted the firm was not documenting all interventions. I observed 3 interventions between the weight check ®@ and ®@. Only one of these interventions was documented. B. Media fills are performed following SOP/QAD/GEN/043-06 Procedure for Aseptic Process Simulation, dated 20 May 2017. This procedure requires all personnel authorized to enter in the aseptic processing and filling area to participate in a media fill run at least [illegible]. The firm does not track personnel activities in media fill. Production operators, Quality Assurance personnel, microbiologists and engineers were listed as being qualified during media fills without performing any interventions. In addition, the firm reports the media fill duration by tracking the start and end time of filling. This does not take into account the extended breaks and the intermittent breaks taken by the operators. For example, media [illegible] specifies the total duration of the fill time as [illegible] and [illegible]. Actual fill time was approximately [illegible] and [illegible]. During these breaks operators stated they ensure open vials are removed from the line. C. The firm does not track the [illegible] used on the closed [illegible] used to manufacture sterile drug product. The [illegible] are given an expiry day by the manufacturer. The [illegible] that have been replaced on the line are documented as not having an expiry date. D. For each pair of sterile [illegible] tested, the firm only requires a minimum of [illegible]. The firm does not ensure that the whole [illegible] is sterile. This applies to both the [illegible]. E. Microbial testing on swab samples is performed using a pour plate method. The [illegible] media should be [illegible] prior to pouring the [illegible] into the plate containing the sample. This equipment used along with the temperature of the media is not documented. Management confirmed the temperature of the media at this step is critical. F. The monitoring program does not cover all critical surfaces that come in contact with the product. The firm does not monitor the filling [illegible] at the conclusion of sterile filling to support sterile conditions were maintained throughout the filling process. G. During the validation of the microbial method used during the analysis of environmental monitoring plates, the actual conditions of use are not validated. The firm does not demonstrate that the microbial growth media provides conditions such that compromised and/or stress organisms are able to propagate within a varied microbial population. In addition, the media used for the [illegible] plate method does not undergo growth promotion for how it is used. Growth promotion is performed [illegible] then moved into the incubator. H. The procedure used for SOP/PDI/GEN/050-05 Procedure to Start Activity in New Facility/After Major [illegible] Activity is not being followed. Operators are not performing the [illegible] activity or the [illegible] hold time as specified in the procedure.

    4. Observation 6

      Stability program/methods not stability-indicating

      The written stability program for drug products does not include reliable, meaningful, and specific test methods. The methods used during the stability program for [illegible] Tablets [illegible] mg & [illegible] mg; Injection, ®® Injection, § mg/ml and ®® & Injection, ® mg/vial have not been proven to be stability indicating. A. [illegible] Tablets [illegible] mg: The stress studies performed during the validation of [illegible] tablets resulted in a mass balance of ®® %% when exposed to [illegible]. This discrepancy was not investigated. Needing to detect all impurities generated from the degradation of [illegible] tablets was not an acceptance criterion. B. [illegible] Injection: Mass balance was not performed during the stress studies performed on [illegible]. Three impurity methods are needed to determine impurities in ®® & Injection. C. [illegible] Injection, [illegible] mg/ml: The acceptance criteria for the stress studies performed during the validation did not require all impurities to be detected. The acceptance criteria are listed as all degradation products if any should be well separated from peak and each other, the peak purity angle should be less than purity threshold as per waters empower - 2 software and calculate the mass balance of stress degradation samples (for information only). The following results were noted during the stress studies: Initial testing / Repeat testing Degradation condition | Control | [illegible] | Control | [illegible] Assay | [illegible] % | [illegible] % | [illegible] % | [illegible] % Mass Balance | [illegible] | [illegible] | [illegible] | [illegible] Due to the [illegible] mass balance, the stress studies for acid and basic conditions were repeated. During the retesting, the sample was not degraded and therefore it still cannot be determined if the method can detect the impurities generated by acid and basic exposure. D. [illegible] Injection [illegible] mg/vial: Not all impurities are integrated during the stress studies and stability testing of [illegible].

    5. Observation 7

      Uncontrolled HPLC data processing methods

      The following issues were noted during the review of the analytical methods used in the finished product release of product for the U.S. market. Specifically, the software used to conduct high performance liquid chromatography (HPLC) analysis of finished product for unknown impurities is configured to permit extensive use of multiple processing methods without scientific justification. For example, during the analysis of impurities, an analyst can change the integration parameters for each sample run including inhibit integration, peak slice minimum area, sensitivity, baseline point, peak group start, peak group end.

    6. Observation 8

      Inadequate sampling/testing acceptance criteria

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release. Specifically there is no evidence that each vial produced meets specification. A. One vial of ®® mg/vial Injection contains [illegible] ppm. The assay method, degradation products method, and [illegible] method requires [illegible] ppm for analysis. The method requires vials of [illegible] vials to be [illegible] prior to testing. The impurity [illegible] method requires an [illegible] ppm sample to be tested. This analysis also specifies [illegible] vials to be [illegible] prior to testing. B. The particle size distribution method used in the analysis of ®® injection [illegible] mg/vial stated [illegible]. Management stated [illegible] vials would fail the particle size test so a different vial would need to be tested. When vials are discarded is not documented. C. The methods for [illegible] Injection USP require the combining of vials prior to preparation of the [illegible] mg sample for assay and related substances analysis (e.g., [illegible] vials). The combining of vials is not specified in the [illegible] Injection official monograph listed in USP.

    7. Observation 9

      Unsupported sample sizes and sampling plans

      Scientific justification could not be provided for the following sample sizes: A. The filling of the validation of Injection USP ng/ml takes approximately [illegible] and fills approximately ®® vials. During the validation the firm sampled [illegible] vials at the [illegible] of the filling process. These [illegible] vials are combined prior to testing to obtain [illegible] result from the [illegible] of the filling process. The vials were tested for description, pH, and assay. This number of vials sampled was not based on statistical rational and the times when these samples are taken is not documented. In addition to these samples, the firm samples ®® vials total from the [illegible] for finished product testing. These vials are compiled prior to being sent to Quality for testing. Of these [illegible] vials, [illegible] sample is tested for assay and impurities. B. The sampling and testing of sterile [illegible] is not based on a statistical evaluation. Instead the firm samples [illegible] pairs of [illegible] regardless of the amount received. Receiving lots can range from [illegible] pairs of [illegible]. C. The sample size for the testing of [illegible] is not appropriate for the expected microbial count of the [illegible], in order to derive statistically valid colony counts. The firm did not obtain any CFUs for the 12 month period reviewed. D. The process validation for [illegible] Injection mg/vial only requires [illegible] sample analysis during filling from the [illegible] of the filling to ensure product uniformity.

    8. Observation 10

      Visual inspection defects not included

      The following defects are not reflected in the visual inspection Kits used to train the visual inspectors; vial/liquid, vials: Sealing (non-integral), broken/cracks, changes in liquid color, absence of stopper/seal, less volume, more volume, color particle, coding, empty vial, molding defects, scratches, spot on [illegible], spot on seal. vial/liquid, vials: Broken/cracks, less volume, more volume, empty, appearance, sealing (non-integral). vial [illegible] vials: Broken/cracks, [illegible] or black particle, glass particle. vial [illegible] vials: Sealing (non-integral), broken/cracks, glass particle, change in [illegible] color, absence of stopper/seal, [illegible] colored particle, coding, empty vial, molding defects, spot on [illegible], spot on seal.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Dec 4, 2025. It asked for a Form 483.

  • Inspection ending Nov 10, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Jan 9, 2026. FDAgent holds no copy that FDA posted.

    1. Dec 4, 2025FDA-FOIA-2025-13587Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 7 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
SHILPA MEDICARE LIMITEDD-U-N-S 858360192

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names SHILPA MEDICARE LIMITED (D-U-N-S 858360192) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • SHILPA MEDICARE LIMITEDIndia · FEI 30186942372 inspections2latestMay 29, 2026None on file
  • SHILPA MEDICARE LIMITEDHyderabad, India · FEI 30197734581 inspection1latestMar 10, 2023VAINone on file
  • SHILPA MEDICARE LIMITEDBengaluru, India · FEI 30106194011 inspection1latestFeb 13, 2019VAINone on file
  • SHILPA BIOLOGICALS PRIVATE LIMITEDKarnataka, India · FEI 3022989727Registered; no FDA inspection on file

Other FEIs recorded as Shilpa Medicare Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3009876430 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3009876430. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.