Dr. Reddy's Laboratories Ltd.
India
FEI 3014250111DUNS 918608167
FDA has 6 inspections on file for Dr. Reddy's Laboratories Ltd. in India (FEI 3014250111), from 2015 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
6 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing and packing, through Dec 31, 2026. Its registrant is DR.REDDY'S LABORATORIES LIMITED (D-U-N-S 918608167).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 6, 2015–2026
- 0 OAI · 1 VAI · 3 NAI
- Inspections with 483 observations shown
- 2 of 6
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 3 requests, latest Jul 23, 2026
- Warning letters
- None on file
- Import refusals
- 6 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic practices for sterile filling
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate aseptic practices. During filling of (b)(4) drug product batch (b)(4) on June 18, 2026, in the filling line, number (b)(4) inadequate aseptic practices were observed. Specifically, A. The (b)(4) and stopper bowl were assembled into the (b)(4) and were uncovered prior to initiation of the (b)(4) decontamination cycle. As a result, these sterilized components were exposed to the (b)(4) decontamination agent prior to filling operations, compromising the sterility of these items. Sterilized components introduced into the (b)(4) should not be subjected to conditions that could compromise their sterility assurance. B. During loading of (b)(4) sterilized stoppers into the (b)(4), the (b)(4), which is not sterilized and is only exposed to the (b)(4) decontamination cycle, is positioned directly above the (b)(4). When (b)(4), the (b)(4) blocks unidirectional first air to the (b)(4), exposing the sterilized (b)(4) to potential microbial contamination. C. During loading of the (b)(4), a large number of sterilized stoppers into the (b)(4) positioned above stoppers were observed making direct contact with an unsterilized (b)(4). Contact between sterilized stoppers and an unsterilized surface compromise the sterility of the stoppers prior to their placement on vials. D. During installation of the (b)(4), each (b)(4) was assembled onto a non-sterile (b)(4). Although each (b)(4) was individually protected by a cover prior to installation, the top of each protective cover was observed contacting the unsterile (b)(4). Upon removal of the protective cover, the cover was slid along the full length of the (b)(4), such that the top portion of the cover contacted the entire length of the (b)(4), including the (b)(4). This practice compromises the sterility of the (b)(4) and presents a direct contamination risk to the drug product. E. The (b)(4), under which vials are capped during the stoppering operation, is positioned such that it blocks unidirectional first air to all vials passing beneath it. The (b)(4) is not sterilized and is only exposed to the (b)(4) decontamination cycle. Because all vials must pass under this (b)(4) during stoppering, this unsterilized surface is in direct proximity to open vials and exposed stoppers, representing an uncontrolled contamination risk to the drug product. F. During filling of (b)(4) drug product batch number (b)(4) on June 22, 2026, in (b)(4) Restricted Access Barrier System (RABS) vial filling line (Grade A within a Grade B environment), inadequate aseptic practices were observed. Specifically, i. Operators were observed moving back and forth between the Grade B area and the Grade A air-supplied area outside the RABS through which stoppered vials transit via conveyor belt to the capping machine. Although a (b)(4) is present between the operators and the stoppered vials on the conveyor, operators were observed reaching (b)(4) into the Grade A zone to manually discard vials identified as lacking stoppers or as (b)(4). This practice introduces personnel, who have been present in the lower-classified Grade B environment, into direct proximity with vials within the Grade A zone, compromising the sterility potentially (b)(4) of the drug product. The repeated ingress and egress of operator arms (b)(4), disrupts the integrity of the (b)(4), as well as operators extending over the (b)(4) Grade A air supply and increases the risk of microbial contamination of the drug product. This inadequate aseptic practice is visible at minute 10:59:19 in airflow simulation video IMN09, titled "Removal of unstoppered or (b)(4) or fallen vials over (b)(4) conveyor (Smoke Study, (b)(4))", filmed on August 22, 2025.
- Observation 2
Inadequate aseptic environmental monitoring program
Aseptic processing environmental monitoring procedures are inadequate in the (b)(4) filling line. Specifically, A. On June 24, 2026, following filling of (b)(4) drug product batch number (b)(4), environmental monitoring failed to include viable surface monitoring of the (b)(4) and stopper bowl. The inadequate (b)(4) design does not allow for effective monitoring strategies for these indirect product-contact surfaces, which compromises sterility assurance of the drug product as the potential microbial load on these components during filling operations remains unknown. B. On June 23, 2026, following filling of (b)(4) drug product batch number (b)(4) and (b)(4) drug product batch number (b)(4), improper (b)(4) fingertip contact plate monitoring technique was observed, as approximately only one second of non-rolling finger contact with the contact plates was observed. This inadequate contact time undermines the reliability of environmental monitoring data. C. On June 23, 2026, during environmental monitoring of the (b)(4) module of the (b)(4) following filling of (b)(4) drug product batch (b)(4), complete absence of a non-viable particle monitor in the transfer conveyor number (b)(4) area during (b)(4) unloading was observed. This constitutes a critical gap in the environmental monitoring program as adequate air quality control during a sterility-critical operation cannot be demonstrated.
Show observations 3 to 7
- Observation 3
Inadequate microbial controls for drug substance intermediates
The (b)(4) (b)(4) drug substance manufacturing process lacks adequate controls to prevent microbial contamination of in-process intermediates. Specifically, (b)(4) (b)(4) microorganism, was identified in the [illegible] indicating (batch number (b)(4)) contamination events across multiple unit operations.
- Observation 4
Smoke studies show blocked first air
Aseptic practices observed in air visualization studies drug product filling operations are inadequate in that first air was obstructed in different (b)(4) critical zones during aseptic processing interventions. Specifically, i. Airflow visualization (smoke) studies conducted on 17/12/2024 (December 17, 2024) for Intervention: Filling machine (b)(4) adjustment vial maximum load (b)(4) at (b)(4), show that a (b)(4) positioned above the (b)(4) would likely block first air to all vials as they are transported in the (b)(4). ii. Airflow visualization (smoke) studies conducted on 19/12/2024 (December 19, 2024, 19:22:22) for Intervention: Adjustment of stoppering machine parts (b)(4), show that a (b)(4) and a (b)(4) hand blocked first air to (b)(4) positioned above the (b)(4) exposed stoppers. The (b)(4) hand were positioned such that they blocked first air to either open vials and/or (b)(4) exposed stoppers (direct product-contact surfaces) in Grade A critical zones within the (b)(4) during inherent and non-inherent interventions, increasing the risk of microbiological contamination of the sterile drug product.
- Observation 5
Inadequate visual inspection defect classification and qualification
The visual inspection program for (b)(4) drug product is inadequate. Specifically, A. The classification of defect categories (i.e., critical, major, and minor) is not adequately justified. For example, black and colored particles, which present a significant risk to patient safety and are indicative of potential contamination, have been inappropriately classified as major defects rather than critical defects. B. Visual inspection qualification kits include vials marked with numbers visible to personnel performing qualification testing. This practice compromises the integrity of the qualification process, as inspectors may become familiar with the identity and location of defective vials prior to qualification testing.
- Observation 6
Failure to review bioburden and investigate growth
Your firm failed to review in-process bioburden testing results for (b)(4) drug substance, (b)(4) samples. The microorganism as microbial colony growth was detected in multiple in-process (b)(4) recoveries were not identified, and root cause investigations were not performed. Specifically, A. Batch No. (b)(4): Bioburden testing conducted on April 25, 2025, yielded (b)(4) microbial colonies. B. Batch No. (b)(4): Bioburden testing conducted on May 2, 2025, yielded (b)(4) microbial colony. C. Batch No. (b)(4): Bioburden testing conducted on May 10, 2025, yielded (b)(4) microbial colonies.
- Observation 7
Inadequate aseptic operator training records
Your firm failed to ensure that operators working in aseptic manufacturing areas are adequately trained, as evidenced by deficient On-the-Job Training (OJT) records for personnel in the (b)(4) area. Specifically, Review of the On-the-Job Training Record (record number (b)(4)) for Employee ID: (b)(6) shows that individual skill training sessions for critical aseptic manufacturing operations were documented as lasting as few as 29 minutes (Participate in BPR execution and closure activity, documented November 10, 2025, (b)(4)) and 9 minutes (Procedure for operation and cleaning of (b)(4) LAF, documented November 10, 2025, (b)(4)). These session durations do not provide reasonable assurance that the employee received sufficient training to competently perform complex aseptic operations, including equipment cleaning and sterilization activities that are critical to product sterility assurance.
- Not classified yetClassification not posted yetDrug product ManufacturerPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inaccurate environmental monitoring data
The Quality Unit has not established adequate procedural controls and oversight to ensure the accuracy of environmental monitoring data. Environmental monitoring data from data collection sheets are manually entered into uncontrolled electronic spreadsheets, which are subsequently used to generate reports and graphical analyses. During the inspection, multiple discrepancies and inaccuracies were identified between the source data and the corresponding reports. Due to inaccurate and incomplete environmental monitoring data, the effectiveness of corrective and preventive actions (CAPA) implemented in response to Observation 2 from the Form FDA 483 issued October 2023 cannot be adequately assessed. Specifically, A. Deviation reports contained inaccurate data on mold recoveries. i. Deviation DV2000016762 report lists inaccurate mold counts data which differ from source data form (FORM-BTO-QC-0108, Doc. Control no. 72). B. CbTO Trend Analysis Summary Report for Environmental Monitoring (OT0-003811, Version 1.0, dated April 8, 2025) which did not include mold recoveries compared to corresponding deviation reports or discrepancies: i. Section 4.1. No. of Fungal Recoveries in Grade C and D areas as per (b)(1-4) graph (Figure-2: Graphical representation of (b)(1) Fungal recoveries in Grade-C & D from (b)(1-4) fungal trend in Grade-C & D) lacked a y-axis label. Although the firm stated the y-axis represents cumulative mold recoveries (CFU) per (b)(6) mold recovery data from related deviations (DV2000016618, DV2000016662, and DV2000016965) were not accurately included in the analysis. ii. Section 4.2. Fungal counts recovery in Grade-C Settle plate monitoring excluded deviations (DV2000017128 and DV2000015438) for analysis. iii. Section 4.3. Fungal counts recovery in Grade-C Active air sampling excluded deviations or contained inaccurate data (DV2000015799, DV2000015522, DV2000018464) for analysis. iv. Section 4.4. Fungal counts recovery in Grade-D Settle plate monitoring contained the following discrepancies: a. Graph 4.4.1 heading incorrectly stated "graphical representation of fungal counts recovery in Grade D Active air monitoring," while the graph was labeled "Fungal counts in Settle plate Grade-D". b. Fungal counts recovery in Grade-D Settle plate monitoring contained inaccurate data from deviations (DV2000016762). v. Section 4.5. Fungal counts recovery in Grade-D Active air sampling excluded deviations or contained inaccurate data (DV2000017472 and DV2000016662) for analysis. C. Summary of retrospective assessment for incident related to environmental monitoring excursions in facility (Duration: [illegible] to [illegible], document No. RP-BTO-004435, Version 1.0, Approved on September 1, 2025) contained incomplete and inaccurate data presentation. The summary graph entitled "Mold recoveries: No. of instances with mold recoveries observed with count from 1 (b)(6) facility (From (b)(TC) to (b)(T4)), failed to include all documented mold counts (CFU) for grade-D classified areas from (b)(TC) to (b)(T4).
- Observation 2
Inadequate document control system
The firm failed to establish adequate document control procedures and oversight mechanisms to ensure appropriate management of written documents. Specifically, The current DOCHUB system permits users to download approved documents in Microsoft Word format without embedded approval signatures. This system configuration creates the potential for unauthorized document modification, as users can alter content and subsequently save documents in PDF format, generating uncontrolled copies. This practice is inconsistent with the firm's own work instruction document (WI-GLOB-IT-0304, effective July 12, 2024), which restricts export or printing of uncontrolled document copies to authorized document coordinators and system administrators only. Specifically, documents (No. RP-BTO-001232, RP-BTO-001234, RP-BTO-001235, RP-BTO-001237 and RP-BTO-001238) provided in PDF format (in response to records requests pursuant to Section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act) displayed approval status but lacked the required approval signatures of reviewing and approving officials and approval dates.
Show observations 3 to 5
- Observation 3
Inadequate aseptic setup and techniques
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate aseptic techniques during aseptic filling setup for (b)(4) (Batch No. (b)(6)). Specifically, A. Precautions to reduce the potential block of first air were not followed during aseptic fill line set up for (b)(4) filling on September 8, 2025 to assure sterility of the unprotected sterile surfaces. i. During stopper bowl installation, a part of the open stopper bowl was placed below the non-sterile work which blocked first air for the open stopper bowl. ii. During stopper bowl installation, a part of the open stopper bowl was placed below the non-sterile work which blocked first air for the open stopper bowl. The operator was observed blocking first air to stoppers in the stopper bowl while using the (b)(4) to open the (b)(4) to add stoppers to the stopper bowl. The smoke study video (at time stamp April 21, 2025, video name CbTC41 CbTC41 ...) also shows blocking the first air to stoppers in the stopper bowl while opening the (b)(4) to add more stoppers to the stopper bowl. iii. During installation, the (b)(4) were mounted onto the non-sterile (b)(4). As a result, the non-sterile work blocked first air for the (b)(4) during filling operation. iv. During stopper bowl installation, a part of the open stopper bowl was placed below the non-sterile work and blocked first air for the open stoppers. After the covers were removed with the tweezers, the operator was observed blocking first air to the unprotected (b)(4) while adjusting the (b)(4). B. (b)(4) were utilized during operations. However, post-1mgsampling procedures involved contact plate sampling of only (b)(4) thereby preventing assurance of sterility of (b)(4) surfaces. C. The sterility of (b)(4) could not be assured due to the placement of a (b)(4) positioned below the (b)(4) at the initiation of filling operations to collect (b)(4). The (b)(4) collected in the (b)(4) presented a risk of (b)(4). Additionally, the (b)(4) cannot be considered sterile as it undergoes sanitization only during (b)(4) procedures rather than sterilization. D. Small area of open skin was noticed between the goggles and the mask of one of the operators (b)(4) during the fill line set up. Open skin was also noticed on the smoke study video of interventions (Time stamp April 21, 2025 video name: ...).
- Observation 4
Insufficient viral cross-contamination risk assessment
The risk assessment (QUA-BTO-2275 - Risk assessment for viral cross-contamination control in drug product manufacturing; with (b)(4) sterility, Version 7, approved on August [illegible], 2025) for viral control at Dr. Reddy's Laboratories is inadequate to mitigate the potential virus cross-contamination risk of (b)(4) drug product (DP) and does not align with the current industry standards and ICH Q5A guidelines. The manufacturing of (b)(4) intended for the United States market is conducted in a shared manufacturing facility (b)(4) which concurrently processes multiple drug products for non-United States markets, including (b)(4). The drug substance for these non-United States market products is manufactured in facilities (b)(4) (with the exception of (b)(4) which is manufactured in (b)(4)). Unprocessed bulk harvest materials for non-United States market products manufactured in (b)(4) do not undergo routine adventitious virus testing for commercial production batches. While (b)(4) manufacturing within (b)(4) utilizes dedicated product contact equipment, non-United States market DP that have not undergone the adventitious virus testing share the same Restricted Access Barrier Systems (RABS). Most shared surfaces are sanitized but not sterilized between product changeovers. Although the risk assessment proposes cleaning and sanitization strategies, these strategies fail to demonstrate elimination of viral cross-contamination risk.
- Observation 5
Inadequate documentation and analysis
Written documents are inadequate to ensure proper documentation and analysis of critical manufacturing operations. Specifically, A. Report VALRP-BTO-002395, Summary report for airflow visualization study and assessment of aseptic interventions during vial filling (b)(4) (Version 1.0, approved on September 3, 2025), failed to provide a comprehensive analysis of the smoke study videos and contained only a checklist of interventions performed. The report did not adequately evaluate or document critical observations from the video footage that could impact sterility assurance. Specifically, raw smoke study videos (file name: CbT(4) Timestamp: August 21, 2025) showed some smoke moving against the flow direction with observable turbulence, indicating potential disruption of unidirectional airflow patterns. However, this event was not documented, analyzed, or addressed in the corresponding report. B. Report VALRP-BTO-002193 - 50 ml, Revalidation of (b)(1) (version 1.0, approved on February 20, 2025), does not contain complete record of data and comprehensive analysis for major tests, including (b)(4) test and endotoxin challenge study. Each test result is documented with only a single sentence described as "Observations," which fails to provide the detailed data analysis and comprehensive evaluation necessary to demonstrate that the equipment consistently performs as intended. C. SOP-BTO-PR-0393, Aseptic Assembling and disassembling of Sterilized Accessories of Vial Filling and Stoppering Machine CbTC4vF-01 (Version 12, effective date August 8, 2025), Step (b)(4) lists an operation that was not performed. Specifically, step (b)(4) required to (b)(4) at the (b)(4) of the filling machine. However, this operation was not performed during the filling line setup on September 8, 2025.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 23, 2026. Each one asked for a Form 483.
Inspection ending Jun 25, 2026Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 23, 2026FDA-FOIA-2026-7089Form 483Records released
- Jun 26, 2026FDA-FOIA-2026-6139Form 483No records found
Inspection ending Oct 12, 2023
1 request. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.
- Mar 6, 2025FDA-FOIA-2025-2084Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3014250111, one row per refused product line.
6 refusals from 2017-05-23 to 2022-09-08 · charged UNAPPROVED on 5, NOT LISTED on 3 · no FDA sample analysis
FDA firm profile- 2022-09-08
MISCELLANEOUS PATENT MEDICINES, ETC.66VBY99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-3327961-6/11/3
- 2021-06-07
PRAVASTATIN SODIUM (ANTI-CHOLESTEREMIC)61JCA13
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4758501-5/11/4
- 2020-06-03
LOSARTAN POTASSIUM (ANTI-HYPERTENSIVE - PART II)62OCY41
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7118146-4/11/1
- 2018-03-12
ANTI-DIABETIC N.E.C.61PDA99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4268544-3/21/1
- 2018-02-14
MISCELLANEOUS PATENT MEDICINES, ETC.66VDY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-4500118-5/11/1
Show 1 more
- 2017-05-23
CIPROFLOXACIN (ANTI-BACTERIAL PART I) (NOT ANTIBIOTIC)61FCA54
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Northeast ImportsJ37-0009050-2/71/1F
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing
- Registration runs through
- Dec 31, 2026
- Registrant
- DR.REDDY'S LABORATORIES LIMITEDD-U-N-S 918608167
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Dr. Reddy's Laboratories Ltd.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Dr. Reddy's Laboratories Ltd.FEI 3006549835Visakhapatnam, India
Last inspected 2024-05-17VAI
Dr. Reddy's Laboratories Ltd.FEI 3002949099Medchal-Malkajgiri District, India
Last inspected 2023-10-27VAI
Dr. Reddy's Laboratories Ltd.FEI 3011171511Ranasthalam Mandal, Srikakulam, India
Last inspected 2023-05-12VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014250111 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014250111. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.