Dr. Reddy's Laboratories Ltd. Form 483, June 2026
FDA issued this Form 483 to Dr. Reddy's Laboratories Ltd. in India (FEI 3014250111) at the end of an inspection that ended June 25, 2026. It lists 7 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 25, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Nov 13, 2026
- 141 days after the inspection
The 7 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate aseptic practices for sterile filling
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate aseptic practices. During filling of (b)(4) drug product batch (b)(4) on June 18, 2026, in the filling line, number (b)(4) inadequate aseptic practices were observed. Specifically, A. The (b)(4) and stopper bowl were assembled into the (b)(4) and were uncovered prior to initiation of the (b)(4) decontamination cycle. As a result, these sterilized components were exposed to the (b)(4) decontamination agent prior to filling operations, compromising the sterility of these items. Sterilized components introduced into the (b)(4) should not be subjected to conditions that could compromise their sterility assurance. B. During loading of (b)(4) sterilized stoppers into the (b)(4), the (b)(4), which is not sterilized and is only exposed to the (b)(4) decontamination cycle, is positioned directly above the (b)(4). When (b)(4), the (b)(4) blocks unidirectional first air to the (b)(4), exposing the sterilized (b)(4) to potential microbial contamination. C. During loading of the (b)(4), a large number of sterilized stoppers into the (b)(4) positioned above stoppers were observed making direct contact with an unsterilized (b)(4). Contact between sterilized stoppers and an unsterilized surface compromise the sterility of the stoppers prior to their placement on vials. D. During installation of the (b)(4), each (b)(4) was assembled onto a non-sterile (b)(4). Although each (b)(4) was individually protected by a cover prior to installation, the top of each protective cover was observed contacting the unsterile (b)(4). Upon removal of the protective cover, the cover was slid along the full length of the (b)(4), such that the top portion of the cover contacted the entire length of the (b)(4), including the (b)(4). This practice compromises the sterility of the (b)(4) and presents a direct contamination risk to the drug product. E. The (b)(4), under which vials are capped during the stoppering operation, is positioned such that it blocks unidirectional first air to all vials passing beneath it. The (b)(4) is not sterilized and is only exposed to the (b)(4) decontamination cycle. Because all vials must pass under this (b)(4) during stoppering, this unsterilized surface is in direct proximity to open vials and exposed stoppers, representing an uncontrolled contamination risk to the drug product. F. During filling of (b)(4) drug product batch number (b)(4) on June 22, 2026, in (b)(4) Restricted Access Barrier System (RABS) vial filling line (Grade A within a Grade B environment), inadequate aseptic practices were observed. Specifically, i. Operators were observed moving back and forth between the Grade B area and the Grade A air-supplied area outside the RABS through which stoppered vials transit via conveyor belt to the capping machine. Although a (b)(4) is present between the operators and the stoppered vials on the conveyor, operators were observed reaching (b)(4) into the Grade A zone to manually discard vials identified as lacking stoppers or as (b)(4). This practice introduces personnel, who have been present in the lower-classified Grade B environment, into direct proximity with vials within the Grade A zone, compromising the sterility potentially (b)(4) of the drug product. The repeated ingress and egress of operator arms (b)(4), disrupts the integrity of the (b)(4), as well as operators extending over the (b)(4) Grade A air supply and increases the risk of microbial contamination of the drug product. This inadequate aseptic practice is visible at minute 10:59:19 in airflow simulation video IMN09, titled "Removal of unstoppered or (b)(4) or fallen vials over (b)(4) conveyor (Smoke Study, (b)(4))", filmed on August 22, 2025.
- 2
Inadequate aseptic environmental monitoring program
Aseptic processing environmental monitoring procedures are inadequate in the (b)(4) filling line. Specifically, A. On June 24, 2026, following filling of (b)(4) drug product batch number (b)(4), environmental monitoring failed to include viable surface monitoring of the (b)(4) and stopper bowl. The inadequate (b)(4) design does not allow for effective monitoring strategies for these indirect product-contact surfaces, which compromises sterility assurance of the drug product as the potential microbial load on these components during filling operations remains unknown. B. On June 23, 2026, following filling of (b)(4) drug product batch number (b)(4) and (b)(4) drug product batch number (b)(4), improper (b)(4) fingertip contact plate monitoring technique was observed, as approximately only one second of non-rolling finger contact with the contact plates was observed. This inadequate contact time undermines the reliability of environmental monitoring data. C. On June 23, 2026, during environmental monitoring of the (b)(4) module of the (b)(4) following filling of (b)(4) drug product batch (b)(4), complete absence of a non-viable particle monitor in the transfer conveyor number (b)(4) area during (b)(4) unloading was observed. This constitutes a critical gap in the environmental monitoring program as adequate air quality control during a sterility-critical operation cannot be demonstrated.
- 3
Inadequate microbial controls for drug substance intermediates
The (b)(4) (b)(4) drug substance manufacturing process lacks adequate controls to prevent microbial contamination of in-process intermediates. Specifically, (b)(4) (b)(4) microorganism, was identified in the [illegible] indicating (batch number (b)(4)) contamination events across multiple unit operations.
- 4
Smoke studies show blocked first air
Aseptic practices observed in air visualization studies drug product filling operations are inadequate in that first air was obstructed in different (b)(4) critical zones during aseptic processing interventions. Specifically, i. Airflow visualization (smoke) studies conducted on 17/12/2024 (December 17, 2024) for Intervention: Filling machine (b)(4) adjustment vial maximum load (b)(4) at (b)(4), show that a (b)(4) positioned above the (b)(4) would likely block first air to all vials as they are transported in the (b)(4). ii. Airflow visualization (smoke) studies conducted on 19/12/2024 (December 19, 2024, 19:22:22) for Intervention: Adjustment of stoppering machine parts (b)(4), show that a (b)(4) and a (b)(4) hand blocked first air to (b)(4) positioned above the (b)(4) exposed stoppers. The (b)(4) hand were positioned such that they blocked first air to either open vials and/or (b)(4) exposed stoppers (direct product-contact surfaces) in Grade A critical zones within the (b)(4) during inherent and non-inherent interventions, increasing the risk of microbiological contamination of the sterile drug product.
- 5
Inadequate visual inspection defect classification and qualification
The visual inspection program for (b)(4) drug product is inadequate. Specifically, A. The classification of defect categories (i.e., critical, major, and minor) is not adequately justified. For example, black and colored particles, which present a significant risk to patient safety and are indicative of potential contamination, have been inappropriately classified as major defects rather than critical defects. B. Visual inspection qualification kits include vials marked with numbers visible to personnel performing qualification testing. This practice compromises the integrity of the qualification process, as inspectors may become familiar with the identity and location of defective vials prior to qualification testing.
- 6
Failure to review bioburden and investigate growth
Your firm failed to review in-process bioburden testing results for (b)(4) drug substance, (b)(4) samples. The microorganism as microbial colony growth was detected in multiple in-process (b)(4) recoveries were not identified, and root cause investigations were not performed. Specifically, A. Batch No. (b)(4): Bioburden testing conducted on April 25, 2025, yielded (b)(4) microbial colonies. B. Batch No. (b)(4): Bioburden testing conducted on May 2, 2025, yielded (b)(4) microbial colony. C. Batch No. (b)(4): Bioburden testing conducted on May 10, 2025, yielded (b)(4) microbial colonies.
- 7
Inadequate aseptic operator training records
Your firm failed to ensure that operators working in aseptic manufacturing areas are adequately trained, as evidenced by deficient On-the-Job Training (OJT) records for personnel in the (b)(4) area. Specifically, Review of the On-the-Job Training Record (record number (b)(4)) for Employee ID: (b)(6) shows that individual skill training sessions for critical aseptic manufacturing operations were documented as lasting as few as 29 minutes (Participate in BPR execution and closure activity, documented November 10, 2025, (b)(4)) and 9 minutes (Procedure for operation and cleaning of (b)(4) LAF, documented November 10, 2025, (b)(4)). These session durations do not provide reasonable assurance that the employee received sufficient training to competently perform complex aseptic operations, including equipment cleaning and sterilization activities that are critical to product sterility assurance.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3014250111, newest first.
- Form 483, September 2025FDA record date Sep 12, 2025 · Posted Oct 1, 2025
- Form 483, October 2023FDA record date Oct 12, 2023 · Posted Mar 6, 2025
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.