Tarmac Products, Inc
16311 Nw 52nd Ave, Miami Gardens, Florida, United States
FEI 1025483DUNS 059890491
FDA has 10 inspections on file for Tarmac Products, Inc in Miami Gardens, Florida (FEI 1025483), from 2008 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jun 2, 2011. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
16 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Tarmac Products, Inc. (D-U-N-S 059890491).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 10, 2008–2026
- 2 OAI · 8 VAI · 0 NAI
- Inspections with 483 observations shown
- 8 of 10
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Apr 21, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: Devices7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Management review - defined interval, sufficient frequency
Management with executive responsibility has not reviewed the suitability and effectiveness of the quality system at defined intervals and with sufficient frequency.
Label to bear a unique device identifier
The labels of the medical device(s) do not bear a unique device identifier (UDI) that meet the requirements of 801 Subpart B and 21 CFR 830.
Quality Audits - defined intervals
Quality audits were not performed at defined intervals and at sufficient frequency to determine whether the quality system activities and results comply with quality system procedures.
Evaluation of suppliers, contractors, etc., requirements
Requirements that must be met by suppliers and consultants have not been adequately established.
Lack of System for Event Evaluations
The written MDR Procedure does not include an internal system which provides for timely and effective identification, communication and evaluation of events that may be subject to medical device reporting requirements.
Show 2 more citations
Contamination control, Lack of or inadequate procedures
Procedures to prevent contamination of equipment or product by substances that may have an adverse effect on product quality have not been adequately established.
Devices subject to device identification GUDID data submission requirements.
The information required by the Global Unique Device Identification Database for each medical device version or model required to bear a unique device identifier (UDI) was not provided.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Over-the-Counter Drug Evaluation5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions, sampling and testing procedures, specifications, special notations and precautions to be followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Postmarket Assurance: Devices17 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Lack of Written MDR Procedures
Written MDR procedures have not been developed.
Lack of or inadequate organizational structure
The organizational structure has not been adequately established and maintained to ensure that devices are produced in accordance with 21 CFR 820.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and of adequate size to facilitate operations for its intended use.
Calibration, Inspection, etc. Procedures Lack of or Inadequ
Procedures to ensure equipment is routinely calibrated have not been adequately established.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 12 more citations
Design control - no procedures
Procedures for design control have not been established.
Written program not followed
The written stability testing program is not followed.
Quality audits - Lack of or inadequate procedures
Procedures for quality audits have not been adequately established.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Lack of or inadequate process validation
A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Lack of or inadequate procedures
Procedures for corrective and preventive action have not been adequately established.
Purchasing controls, Lack of or inadequate procedures
Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been adequately established.
Lack of or inadequate complaint procedures
Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been adequately established.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components and drug products.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written procedures not established/followed
Written procedures are not for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Show 4 more citations
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
Specific information required in individual logs
Individual equipment logs do not show lot number of each batch processed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components, drug product containers, closures, in process materials, packaging material, labeling, and drug products.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Written distribution procedure
Written distribution procedures are not established and followed.
Show 7 more citations
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Record information maintained
Records of returned drug products are not maintained.
Individual inventory record
Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Distribution Record Requirements
Distribution records do not contain the lot or control number of drug product.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not appropriately identified and retained.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance19 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Supervisor Training/Education/Experience
Individuals responsible for supervising the processing, packing, and holding of a drug product lack the education, training, and experience to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
Procedures are written, and followed
Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written and followed.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Record maintenance 1 year (except exempt OTC)
All records of production, control, distribution, components, drug product containers, closures, and labeling associated with a batch of drug product are not maintained at least one (1) year after the expiration date.
Show 14 more citations
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Written distribution procedure
Written distribution procedures are not established and followed.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Lack of quality control unit
There is no quality control unit.
Destruction of obsolete labeling
Obsolete or outdated labels, labeling and packaging materials are not destroyed.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established and followed.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Records not kept for each shipment
Records are not maintained for each shipment received of each different labeling and packaging material.
Recall facilitation
A system by which the distribution of each lot of drug product can be readily determined to facilitate its recall if necessary, has not been established.
Retention time of reserve samples, in general
Reserve samples for active ingredients and drug products are not retained for one year after the expiration date of the drug product.
Destruction of excess labels with lot numbers
Excess labeling bearing lot or control numbers is not destroyed.
Expiration date location on labeling
Drug product expiration dates do not appear on the labeling in the manner prescribed by regulations..
Training , Education , Experience overall
Employees engaged in the processing and packing of a drug product lack the education, training, and experience required to perform their assigned functions.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Apr 21, 2026. Each one asked for a Form 483.
Inspection ending Feb 6, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Apr 21, 2026FDA-FOIA-2026-4025Form 483· 1 of 5 sitesRecords released
Inspection ending Nov 4, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 5, 2026. FDAgent holds no copy that FDA posted.
- Jan 14, 2026FDA-FOIA-2026-499Form 483· 1 of 5 sitesRecords released
- Dec 23, 2025FDA-FOIA-2025-14317Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 42 sections of 21 CFR in FDA’s published citations for 8 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit6 of 8
- 21 CFR 211.100Written procedures; deviations4 of 8
- 21 CFR 211.160General requirements4 of 8
- 21 CFR 211.165Testing and release for distribution3 of 8
- 21 CFR 211.170Reserve samples3 of 8
- 21 CFR 211.25Personnel qualifications2 of 8
- 21 CFR 211.56Sanitation2 of 8
- 21 CFR 211.125Labeling issuance2 of 8
Show all 42
- 21 CFR 211.137Expiration dating2 of 8
- 21 CFR 211.142Warehousing procedures2 of 8
- 21 CFR 211.150Distribution procedures2 of 8
- 21 CFR 211.188Batch production and control records2 of 8
- 21 CFR 211.194Laboratory records2 of 8
- 21 CFR 803.17What are the requirements for developing, maintaining, and implementing written MDR procedures that apply to me?2 of 8
- 21 CFR 820.20Management responsibility2 of 8
- 21 CFR 820.22Quality audit2 of 8
- 21 CFR 820.50Purchasing controls2 of 8
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 8
- 21 CFR 211.58Maintenance1 of 8
- 21 CFR 211.63Equipment design, size, and location1 of 8
- 21 CFR 211.67Equipment cleaning and maintenance1 of 8
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 8
- 21 CFR 211.111Time limitations on production1 of 8
- 21 CFR 211.122Materials examination and usage criteria1 of 8
- 21 CFR 211.130Packaging and labeling operations1 of 8
- 21 CFR 211.166Stability testing1 of 8
- 21 CFR 211.180General requirements1 of 8
- 21 CFR 211.182Equipment cleaning and use log1 of 8
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 8
- 21 CFR 211.186Master production and control records1 of 8
- 21 CFR 211.192Production record review1 of 8
- 21 CFR 211.196Distribution records1 of 8
- 21 CFR 211.198Complaint files1 of 8
- 21 CFR 211.204Returned drug products1 of 8
- 21 CFR 801.20Label to bear a unique device identifier1 of 8
- 21 CFR 820.30Design controls1 of 8
- 21 CFR 820.70Production and process controls1 of 8
- 21 CFR 820.72Inspection, measuring, and test equipment1 of 8
- 21 CFR 820.75Process validation1 of 8
- 21 CFR 820.100Corrective and preventive action1 of 8
- 21 CFR 820.198Complaint files1 of 8
- 21 CFR 830.300Devices subject to device identification data submission requirements1 of 8
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Tarmac Products, Inc.D-U-N-S 059890491
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1025483 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1025483. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.