Hospira, Inc.
Kansas, USA
FEI 1925262DUNS 030606222
Company: Hospira, Inc. · Linked by exact D-U-N-S match (141588017) in FDA registration data
FDA has 18 inspections on file for Hospira, Inc. in Kansas (FEI 1925262), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the six FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Aug 15, 2018. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 211.110(a), 21 CFR 211.113(b) and 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant, Hospira, Inc. (D-U-N-S 141588017), has registered 6 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 18, 2009–2026
- 2 OAI · 5 VAI · 10 NAI
- Inspections with 483 observations shown
- 8 of 18
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 6 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
18 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetDrug Product ManufacturerPosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic process control failures
Observation 1: Failure to establish process controls designed to assure that the drug products manufactured have the identity, strength, quality, and purity that it purports or is represented to possess. Specifically, 2. On 02 March 2026, observed was the setup of the mw fill line for ge drug product manufacture lot gy. Including, but not limited to the © LX) observed was the equipment sanitized in Grade D space and assembled to the fy by sanitized {y, hands, with these equipment pieces during manufacture directly above the sterile open ge. Personnel gowning during the assembly process was Grade D gowning, with exposed facial skin within theg. You failed toy, | sterilize the equipment and assemble the equipment to the lye in a manner that provides an optimum equipment surface for manufacture that can reasonably be expected to have an impact of product quality. Furthermore, observed was thee sterilized fy Stopper Bowl and LA covered, where the equipment gq was removed in Grade D space, with the equipment transitioning and assembled to the fill line. The remaining gq, covering the stoppering system was removed immediately at time of installation exposing the sterile gq stopper contact surfaces. Observed was an operator with exposed face skin working near and over the exposed sterile stopper contact surfaces. Thee stopper contact surfaces were not installed in a manner that maintained the quality of the surfaces intended to remain sterile. b. On 03 March 2026, observed was the setup of the sterilized drug product fluid pathway laying on the gq a sanitized surface. The packaging was opened by sanitized 1, with the drug product fluid pathway assembled to the fill line. Although each, will be fy installation, extensive touching of the g assembly by sanitized fy and product pathway tubing interface) failed to maintain the quality of surfaces intended to remain sterile. c. On 03 March 2026, observed during the gq drug product filling process for lot 5 was a forceps tip touching the ge ', a sanitized surface. The same condition was again observed on 04 March 2026. You failed to maintain the quality of the foreeps tip as to only touch another sterile surface. d. On 04 March 2026, observed during production of lot gq, at locations of the stoppering system was the gq partially blocked by packaging material. e. On 05 March 2026, observed during the production of lot gy was fy drug product jy formation at multiple g. You failed to optimize the filling process in mitigation of the observed attribute where the drug product should gq be maintained in the gy. f. For eachg)e into Grade A air space from Grade D, you failed to sanitize the |. During low setup operations, personnel Grade D gowning was observed to come into close proximity with non-classified surfaces, when operators bent over to sanitize equipment on dq, in the Grade D space. Upon entry to the Grade A the back of these gowns contacted the gq and gown sleeves contacted production line surfaces during equipment installation, thereby creating a potential contamination pathway to the aseptic processing environment.
- Observation 2
Inadequate facility design and layout
Observation 2: Equipment and facilities in ge drug product manufacture are not adequately designed or located. Specifically, a. Based on design, the gq fill line for drug product manufacture fails to have a HEPA filter directly above thee stopper bowl. You identified by risk assessment that the area did not have excellent airflow during the ge smoke study, with the risk assessment failing to account for the stoppering system ge intervention for installation and any risk mitigation. There are no intervention smoke studies that includes the assembly of the stoppering system, air pattern testing. There is no viable environmental monitoring at they stopper bowl location, with the total non-viable particle cone at an elevated level above the work surface. b. The ge room wall mounted signage, holder indicating Code and Lot identification creates a gap between the wall and the holding device, a cleaning challenge. c. Your ge used in gq drug product manufacture are near [illegible]. The gg for wo is the room containing the E. You fail to have a risk assessment to identify any system location risk and risk mitigation.
Show observations 3 to 6
- Observation 3
Equipment and facility disrepair
Observation 3: Failure to maintain equipment and facilities in a good state of repair in fy drug product manufacture. Specially. a. Thee used in ge drug product manufacture was observed with deteriorated sealant at ga mounting. The ge near the stoppering system was observed with extensive scoring. b. CA was observed with gy line to an open bucket, along with me below the ge ate locations. QI) was observed with an unsecured electrical box, ay leak and absorbent pads for age leak. o® ww was observed with on the floor from ag valve. c. Your laminar flow hood (LFH) #9589, used during bioburden testing on 4 March 2026, had a rust-like substance on the screws and visible debris on the wipe cloth after wiping the LFH surfaces before testing. Additionally, LFH #9588, located adjacent to LFH #9589, had a rust-like substance on the screws, along the inside upper edges of the hood, and along the inside right edges, as well as, substance adhered to several areas on the inside ceiling of the hood.
- Observation 4
Deficient procedures and training
Observation 4: Procedures in ge drug product manufacture are deficient. Specifically, a. Your firm lacks adequate procedures and training for microbiological plate reading, resulting in inconsistent practices among laboratory personnel. There are no written procedures or documented training records that define the methodology for reading environmental monitoring settle plates and touch plates for microbial growth. On 5 March 2026, laboratory personnel were observed using inconsistent techniques when reviewing environmental monitoring plates. Laboratory Technician ®@ placed plates on the light table for about one second, while Laboratory Technician®® and Team Lead ®@ placed plates on the light table for several seconds, rotated them, and examined them from multiple angles. These inconsistent practices compromise the reliability and accuracy of microbiological results used for environmental monitoring decisions. During endotoxin testing on 4 March 2026, critical testing operations were not adequately proceduralized. The pF procedures associated with this testing do not specify using a vortex machine to mix sample solutions or define a timeframe for adequate mixing. Additionally, the procedures do not include the observed use of aj, to remove bubbles from sample wells prior to placing them in the plate reader (Endotoxin K11715 machine), despite firm personnel stating that bubbles in the wells would invalidate test results. This includes Procedure LAB-27703-30.0 (PR-0728), "Performing the Bacterial Endotoxins Test (USP <85>, USP <86>, EP 2.6.14, IP 4.01)" Effective Date 03 November 2025; procedure TRN-32086, "Performing the Bacterial Endotoxin Test via the Photometric Methods" v3.0, Effective date 04 December 2025; and SOP-96058, "Performing the Bacterial Endotoxin Testing via the Kinetic Assay" v34.0, Effective date 08 November 2025. b. Your procedure, SOP 95112, “Gowning Procedure for Controlled Class IV/ Grade D Areas” v43, Effective date 25 August 2025 fail to prevent cross-contamination in Gowning Room gq for the gq fill line used in drug product manufacture. Your firm has not established a maximum occupancy limit for the gowning room or implemented restrictions to prevent simultaneous gowning and degowning activities. On 3 March 2026, at approximately personnel were observed in Gowning Room personnel were gowning to enter the manufacturing area while one was degowning, all occupying approximatelym@square feet of the available gowning space. Additionally, the Grade D area around the 5 fill line does not have a personnel occupancy limit. On 3 March 2026, during production, m@people were present in this area, resulting in area congestion. c. Procedure SOP-95099, “General Rules and Regulations for all Production Areas”, v74.0, Effective date 25 January 2026 specifies under Cleaning/Sanitization Lockers: All personnel and plant uniform lockers will be sanitized ge) The lockers will be sanitized with a sporicide, gq (refer to SOP-94929), © by an approved locker cleaning crew with a plant security representative coordinating. Observed on 04 March 2026 was the men’s change room lockers with angled top surfaces in an unclean state. Your procedure fails to specify the cleaning of the angled top surfaces.
- Observation 5
Inadequate quality unit oversight
Observation 5: Your firm failed to establish adequate quality control unit oversight with the responsibility and authority to approve or reject production and quality documents. Specifically, a. Your firm lacks adequate quality oversight to ensure Quality Risk Management Reports and change controls are thoroughly conducted and reviewed before approval. For example. i. Quality Risk Management Report Oversight: A Quality Risk Management Report (QRMR) with an effective date of 6 December 2024, stated that the gq ‘Change Frequency PM MCP-5490 should be conducted h 2 ." However, there are two Preventative Management (PM) for the oe MCP 5490 with a frequency to ©® and MCP 5209 with a frequency to replace ge The Quality Unit did not ensure that the current PM aligned with the QRMR, demonstrating inconsistency between the risk assessment and actual preventative maintenance practices. ii. Change Control Oversight: Preventative Maintenance Program Change Request (PMCR) Task Plan #M-P5490QT, PM Schedule #MCP-5490, dated 7 August 2025, stated "cancel PM due to frequency changes in SOP-95715" and “gy are no longer changed gy after SOP 95715 was updated.” However, SOP-95715 does not pertain to the frequency change referenced in the PMCR. b. Your firm lacks adequate quality unit investigations for deviations to implement corrective actions to prevent recurrence. From 2024 to 2026, there have been a total of 6 deviations involving 4) failures on the gy filling line for ge drug product manufacture with similar types of failures identified. oy experienced repeated failures within a 12 month timeframe, with failing on 21 August 2024, and 3 July 2025, and gy failing on 30 June 2025, 29 January 2026, and 8 February 2026, demonstrating ineffective corrective actions to prevent recurrence. c. Your firm lacks adequate quality oversight to ensure Acceptable Quality Level (AQL) samples are taken at intervals that are representative of the entire batch. SOP-96072, Auditing of Production Operations, Section E.3 states, "To obtain representative samples for any configuration type, samples must be taken from a minimum of lz across the batch." i. During review of Visual Inspection (VI) AQL batch results for Batch #4 dated 16 February 2026, a total of ma were produced requiring gu to be sampled at specified intervals. However, the appropriate within the ranges were not sampled for intervals. ii. During review of VI AQL batch results for batch #}y¢ (dated 17 October 2025 a total of were produced requiring ge to be sampled at specified intervals. However, the appropriate within the ranges were not sampled for intervals yg.
- Observation 6
Documentation control and archiving failures
Observation 6: Your firm failed to establish adequate controls to ensure documentation is complete, accurate, appropriately reviewed and traceable. Specifically, On 6 March 2026, a review of laboratory notebooks managed in the chemistry laboratory revealed deficiencies in the issuance, reconciliation and archiving process. According to SOP 95718, "Chemistry Laboratory Operation Procedure,” v71, Effective date 16 November 2025, ag, audit is conducted to confirm that each CQ laboratory notebook owner has possession of their assigned books and to verify that archive activities have been completed. However, a review of the issuance and reconciliation records showed that multiple notebooks have not been returned, with some dated back to 2004. Specifically, one former employee who left the company in 2021 has five outstanding notebooks. Examples of individuals with a high number of unaccounted notebooks are listed that have not been archived, nor has the justification for their non-archival status been documented. - Employee and Status ~~ Notebook Issued Date Number of Notebooks Not Returned 2013 5 2004 10 2014 11 2014 6 2016 5 2017 9
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Exhaust systems inadequate to control air contamination
Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 5 more citations
In-process conformity - examination, sample testing
Your examination and testing of samples did not assure that the drug product and in-process material conformed to specifications.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions and precautions to be followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate investigations of contamination events
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A. You initiated an investigation on 11/27/2017 emanating from mold contamination results read on 11/18/2017 in your Grade A filling area. This event resulted in the rejection of approximately 44 batches of finished product manufactured on [illegible] filling line. This investigation is inadequate because you did not appropriately identify the scope of the investigation, establish the root cause and implement preventive actions or initiate the investigation in a timely period. You suspended production activities on 12/8/2017 after three mold isolates were recovered in these areas and to establish the root cause. You visually identified apparent dried product residue on the underside of the lyophilization tray bed / product path on 12/9/2017. You made no attempt to identify this residue. You sampled the area of the residue which resulted in the recovery of 11 CFUs of mold on 12/15/2017. You identified additional mold isolates near this affected area procured from apparent product residue. You identified a potential source of contamination and sampled this area without conducting a scientifically established sampling plan or worst-case sample locations. You returned to manufacturing during late December 2017. You identified inadequate cleaning as a cause for the apparent product residue on or about 12/9/2017. You identified additional apparent product residue on approximately 7/31/2018 at the same location it was identified on 12/9/2017. B. You failed to adequately investigate approximately 9 previous events when an unknown foreign material / gel was observed adhering to the High Efficiency Particulate Air (HEPA) filter screens. The metal screens are a part of the ceiling in all cleanrooms and are located approximately 4" - 8" from the face of the HEPA filters. On 7/24/2018, we observed an apparent "gel" or other foreign material in the [illegible] line adhering to the HEPA filter screen, later identified as an approximately 3 mm x 3 mm "gel". You failed to document the investigation contemporaneously as well as who inspected the room. You did not immediately extend this investigation to other areas even though this "gel" is used as a part of your HEPA filters. This gel is used throughout your facility in cleanrooms as an integral part of your HEPA filters. C. You initiated an investigation on 9/26/2017 because of a potential data integrity event associated with an in-process auditor per PRID 2011571. The auditor performed visual inspection operations affecting approximately [illegible] lots manufactured from 7/6/2015 through 9/22/2017. The investigation is inadequate because you did not scientifically justify why you chose to analyze the retain data of approximately [illegible] lots. Additionally, you requested lot #81660LL be returned to your control for further evaluation as it was distributed outside of your control. D. You modified your validated parameters on approximately 5/19/2018 associated with your [illegible] stopper washing process. You have no documentation supporting that you assessed the risk of this process change before it was implemented. Specifically, you did not verify that modifying the pressure [illegible] to [illegible] pounds per square inch or the use of a [illegible] load versus a [illegible] load does not adversely affect this process. Your Quality Site Director stated you would open an investigation on 7/31/2018 to assess the risk of this event. E. You identified an activated Diphenhydramine Carpuject unit (critical defect) during your retain examination on 12/20/2017 of lot #73525LL. You identified an operator inappropriately re-incorporating ejected product back into your product stream as a root cause. You modified your written procedures on approximately 3/30/2018 and implemented this preventive action on approximately 4/30/2018. You did not perfor
Shortened here; the PDF has the full text.
- Observation 2
Failure to file Field Alert Reports
OBSERVATION 2 A NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application. Specifically, A. On 11/27/2017, you opened an investigation initiated from mold recovered from a settle plate on line [illegible] in your Grade A area. You visually observed apparent product residue on the underside of the tray bed. This product residue was sampled and yielded 11 CFUs of mold. You made no documented attempt to identify this residue nor how or when this residue was deposited. You identified apparent product residue in this same area again, on 7/31/2018. B. On 9/22/2017, you discovered information resulting in a potential data integrity event associated with an in-process auditor per PRID 2011571. The auditor performed visual inspection operations affecting approximately [illegible] lots manufactured from 7/6/2015 through 9/22/2017. C. On 10/9/2017, you discovered a cracked needle hub (critical A defect) while performing a manufacturing quality audit of Morphine Sulfate Inj. USP, lot #80740LL. You did not submit a Field Alert Report for this event until 2/5/2018. Repeat Observation from 10/2017, 6/2016 and 8/2013
Show observations 3 to 8
- Observation 3
Inadequate aseptic process validation
OBSERVATION 3 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. While reviewing smoke studies conducted in room 323 for Lyophilizer [illegible], the following deficiencies were noted: 1. Prior to unloading of the HEPA cart containing partially stoppered vials, an operator was observed checking the tray number using forceps. Tray check performance gives the operator an opportunity to be close to the partially stoppered vials. The action provides possible contamination of the partially stoppered vials. 2. While loading the Lyophilizer, the operator breached first air and smoke was observed to travel from the operator onto the tray containing partially stoppered vials. 3. Smoke studies conducted do not demonstrate worst case scenario as the lyophilizer was not fully loaded. B. You have no documented scientific justification for personnel monitoring during aseptic filling. Per your Class 100 filling room process, personnel are monitored [illegible]. During a shift, aseptic operators can gown and de-gown multiple times within a day and on the same shift without additional personnel monitoring. C. While observing setup operations on line [illegible] I observed tools used for interventions located in your Grade A area in room 338. In order to use the tools, operators must first compromise first air principles. Repeat Observation from 6/2016 and 10/2012
- Observation 4
Deficient cleaning/disinfection systems
OBSERVATION 4 Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. On 7/23/2018, during the [illegible] fill line, [illegible] were observed un-extended with occluded surfaces. [Illegible] fill line was being setup to produce Glatiramer Acetate Injection 20 mg lot 911253F. B. The following hazardous products are manufactured at the facility: Hydroxyprogesterone Caproate; [illegible]; Fentanyl Citrate; Dexmedetomidine HCL; Liraglutide. All the hormones and steroids manufactured at the facility utilize the same general cleaning room, Room 657. Room 657 is adjacent to [illegible] Room 655 which opens to general corridor 436. While conducting your risk assessment, you failed to consider the following: 1. Room 657 and 655 are both under positive pressure. While cleaning equipment used to manufacture hazardous material in Room 657 there is a likelihood the [illegible] could become contaminated with hazardous material. The contaminated [illegible] room could allow contamination to escape into the general corridor. 2. Inadvertent release of the hazardous material can not be promptly detected as on 26th July 2018 since your current action alarms were set with a delay of [illegible]. Changes in the airflow would not be promptly detected. Repeat Observation from 6/2016
- Observation 5
Inadequate visual inspection controls
OBSERVATION 5 Your examination and testing of samples did not assure that the drug product and in-process material conformed to specifications. Specifically, Your manual / semi-automated / automated visual inspection processes are inadequate for the following: A. Your operators are trained via the [illegible] visual inspection training program which requires qualification specifically using a [illegible]. You have not performed or have performed an inadequate scientific justification regarding your selection of [illegible] as representative or worst case of all primary container closure systems such as ampules (1 mL - 5 mL), amber vials, 100-mL vials, etc. B. On 7/24/2018, I observed 100-mL vials of lyophilized Vancomycin semi-automated inspection processes in room #623 for lot #911903A. Approximately 5 vials failed to make a complete turn during the inspection process during an approximate duration of [illegible]. A full revolution is a requirement to adequately inspect vials for critical A (seal integrity defects) as well as critical B (particulate matter) defects. The vial rollers of the [illegible] semi-manual visual inspection equipment appeared to be malfunctioning. C. You have not performed a risk assessment used as an input in the development of your acceptable quality limits (AQLs). Specifically, you have not included the risk to consumers resulting from the use of defective product such as seal integrity attributes and particulate matter contamination. D. You have not adequately assessed spinning parameters, such as rotations per minute (RPMs) of your [illegible] semi-automated inspection equipment which affect the capability of your visual inspection process. Specifically, you have not established an RPM range or other parameter to control / facilitate the propulsion of particulate matter into solution / suspension immediately preceding the presentation of vials to your inspecting operators. E. You have not adequately evaluated the risk that line speed presents to semi-automated visual inspection operations. You [illegible] qualify your visual inspection operators using approximately [illegible] of inspection time per unit. On 7/24/2018, we observed a line speed of [illegible] during observation of Lyophilized Vancomycin HCl lot #911903A, room #623. F. You have not established in-process defect limits regarding your visual inspection processes in the event a second visual inspection is required. G. You do not have a requirement preventing you from modifying your in-process limits established to monitor process control nor do you limit the amount you change your in-process limits. H. During your statistical evaluation of in-process data used to establish / re-establishment of in-process limits, you exclude statistical outliers. However, you have not performed a substantive review of the investigation to determine if the statistical outlier is in fact a result of a special cause event. I. You do not monitor long term drift during your establishment / re-establishment of in-process limits. Repeat Observation from 6/2016
- Observation 6
Unverified supplier certificates of testing
OBSERVATION 6 Certificates of testing of containers are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals. Specifically, You have not performed a risk assessment or have performed one which is inadequate. You have not fully qualified your vendor's Certificate of Conformance. Specifically, you have not inspected incoming molded glass vials for [illegible]. This defect type is included on your suppliers' Certificates of Conformance. You have no documented scientific justification precluding you from testing for this defect.
- Observation 7
Insufficient employee training and trending
OBSERVATION 7 Employees engaged in the manufacture, processing, packing, holding of a drug product lack the training required to perform their assigned functions. Specifically, Your training is inadequate for the following: A. Retain inspectors / operators are trained via the [illegible] visual inspection training program which requires qualification based using a [illegible]. You have no documented scientific justification establishing why the [illegible] is representative or worst case of all primary container closure systems such as ampules (1 mL - 5 mL), amber vials, 100-mL vials, etc. B. You do not trend time elapsed since last personnel training regarding visual inspection processes. You have re-inspected approximately 300 of [illegible] batches manufactured since approximately 10/10/2017. C. You have no valid rationale for dismissing personnel training as a root cause for your positive sterility test noted in Laboratory Investigation PRID 1993529. You did not trend to determine whether your analyst has previously performed positive sterility test. Repeat Observation from 10/2017
- Observation 8
Equipment design fails to limit particulates
OBSERVATION 8 Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, Your [illegible] equipment which processes plungers and stoppers for your sterile drug products has not been performed adequately. You have not scientifically supported this process reduces particulate matter to an acceptable level. Your Process Qualification Report states this washing equipment should effectively remove particulates to an acceptable level. However, data used in this evaluation exhibit no reduction in particulates greater than [illegible] microns in size and a reduction of one particulate from the approximate [illegible] micron sized particles. Repeat Observation from 10/2017
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesPosted 483 · 10 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate discrepancies
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A. You have received approximately 50, 43 and 46 lack of effect complaints for Bupivacaine HCl with Dextrose (Marcaine) lots 550503A, 641003A and 641403A, respectively. These complaints were received from approximately 02/09/2016 to 10/26/2017. A trend notification and a Supplemental Medical Review were conducted, but no action or additional testing was performed. To date, there has not been any additional testing or adequate trend analysis performed for these lots. B. During retain examination of Hydromorphone HCl lot 510053 (ANDA 078591), 15 of [illegible] vials exhibited particulate matter, which was identified on 07/15/2016 as silicone based. This investigation began on 07/12/2016 and was not completed until 07/27/2017, with a recall initiated on 07/31/2017. C. The complaint investigation for a vial of Vancomycin HCl for Injection lot 632153A (ANDA 062912), is inadequate in that it did not address potential inadequacies of the visual inspection process. A complaint vial was returned with a hair partially embedded in the stopper section that is inside of the vial. During the complaint investigation, the visual inspection process was not identified as a contributing factor for the distribution of the returned product. D. During the (b)(4) requalification run the (b)(4) depyrogenation tunnel located on Line (b)(4), two of the (b)(4) endotoxin challenge samples failed to meet the acceptance criteria of a 3-log reduction of endotoxin indicators. During this Validation No. 0062.00-17-0028 "Depyrogenation Endotoxin Indicator Study" performed 11/01/17, two of the 4 (b)(4) samples had results that achieved a log reduction of (b)(4) and the second 4 sample yielded a result of [illegible]. As a part of this investigation, you reported complaints were evaluated. You did not look at adverse events reported during the time you had acceptable qualification results reported until the time when the failing endotoxin indicator results were reported during the (b)(4) Tunnel Validation. REPEAT OBSERVATION from 6/8/2016
- Observation 2
Inadequate employee training
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. Specifically, Employees performing your incoming quality visual inspection process associated with your glass components are not adequately trained. Your employees do not utilize physical glass components nor do you objectively measure this training process. This incoming quality inspection is critical to the prevention of container/closure integrity defects which affect critical attributes such as sterility and potency. The glass components are used as the primary container in all your sterile products including but not limited to Vancomycin HCl Injectable (numerous ANDA/INDAs), Marcaine HCl/Bupivacaine HCl Injectable (numerous ANDA/INDAs), Levophed/Norepinephrine Bitartrate Injectable (ANDA 007513), Diltiazem HCl Injection (ANDA 074941, 075853), etc.
Show observations 3 to 10
- Observation 3
Unqualified labeling inspection equipment
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, You have not appropriately qualified your automated visual inspection labeling process used as your in-process control for lot and expiry label defects. A. Your qualification required the successful rejection of approximately defective units and it did not provide any detail surrounding the magnitude of the lot or expiry defects presented to your visual inspection equipment. Additionally, your equipment is designed to reject defective units when (b)(4) of the surface area of the lot or expiry is missing. B. You manually inspect approximately 1 [t:> (4)] finished units for defects including but not limited to lot and expiry critical text. Batch sizes for these products and packaging configurations routinely approach [(t:>) (4)] units. Therefore, your sampling size is inadequate to provide statistical assurance for lot and expiry defects. Additionally, these types of defects are classified as general appearance and assigned an AQL of (b)(4). This process affects products to include but not limited to your ADD-Vantage configurations such as Diltiazem 500mg, Vancomycin 500mg/750mg/1g, Erythromycin 100mg, and Azithromycin 500mg.
- Observation 4
Reserve sample visual examination lacking
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically: Your SOP does not appropriately classify deterioration to your critical text, namely lot number and expiry. You classify faded print to the critical text fields of lot number and expiry as minor with AQLs for this defect type of (b)(4). A randomly selected retain review of Vancomycin HCl Injectable Lot 67230DD identified approximately [illegible] units with faded lot numbers. REPEAT OBSERVATION from 6/8/2016
- Observation 5
Inadequate aseptic cleaning practices
Cleaning procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, A. The mop used to clean the walls of the filling room with (b)(4) was stored upright on a cart that also contained a box of sterile (b)(4) wipes used for cleaning. The mop was observed to be dripping onto the floor, and had the potential to drip into the container of sterile (b)(4) wipes when the lid was removed to obtain a clean wipe. This storage configuration has the potential to spread contamination cleaned from a wall to areas that are cleaned with the sterile (b)(4) wipes, such as windows and plexiglass in the filling room. B. (b)(4) cleaning of windows and plexiglass with (b)(4) in the (b)(4) filling room is not documented in the Sanitation Log Book, only the walls and ceilings being cleaned with (b)(4) is documented. While two different sporicidal agents are used in this room, they are not rotated so that each surface type is cleaned with two different sporicidal agents. C. On 10/21/17, during the aseptic cleaning of (b)(4) filling room, we observed employee, User ID no. (b)(6), perform cleaning and sanitization operations which included the following inadequate cleaning practices. 1. Overlapping strokes were not always used when cleaning the walls. 2. Missed cleaning different areas in the room, including but not limited to the reject bin and sample port. 3. The employee was observed stepping back onto the cleaned floor area where he had mopped and did not re-mop that area. D. During the aseptic simulation (media fill) of Line (b)(4) you do not record or simulate all activities/interventions which occur during routine sterile processing operations. For example, the frequency for the activities you classify as "Inherent Interventions" such as loading stoppers, fill volume checks, traying vials, etc. are not accounted for during your aseptic fill operations.
- Observation 6
Failure to file Field Alert Reports
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application. Specifically, A. On 01/10/2017, an Out of Specification (OOS) result was obtained for Vancomycin HCl for Injection lot 620203A (ANDA 065455), during potency assay testing at the (b)(4) month stability timepoint. The initial result was not invalidated, and you had inadequate documentation to attribute the assignable cause to analyst error. Additional samples completed testing on 01/27/2017, and were within specification. The time elapsed between these two events was 13 working days, and a Field Alert Report (FAR) was not filed for the original OOS result. B. On 2/1/2017, you received a complaint for defect type missing label associated with Vancomycin HCl lot 610403A. A Field Alert Report was not filed until 3/1/2017. C. Demerol Injectable Lot no. 490903A reported in PRID 1539131 which was created July 11, 2016. This report documents the reserve sample for this product had been reviewed on 7/16 by employee UID (b)(6) and found a Critical A crack/damaged unit on 6/14/49003A, which was confirmed by MQ Supervisor UID (b)(6). The Initial FAR was not filed until July 18, 2016 for this event. D. Labetalol Hydrochloride Inj. USP 5 mg/mL, 4 mL in 5 mL Carpuject Luer Lock, lot no. 55595LL reported in PRID: 1539291 created on July 11, 2016, reported reserve samples were evaluated on 7/5/15 by employee [illegible] and found a Critical A crack/damaged unit on 6/14/55595LL which was confirmed by MQ Supervisor UID (b)(6). The Initial FAR was not reported until July 18, 2016. REPEAT OBSERVATION from 8/16/2013 and 6/8/2016
- Observation 7
Incomplete investigation records
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always included the conclusions and follow-up. Specifically, In your Annual Product Reviews for the following products you identify trends but fail to initiate appropriate corrective and preventive actions to address and correct these failures. A. Marcaine HCl 0.75% w/Dextrose 8.25% Injection, for the review period of 4/2/2016 to 4/1/2017 you identified a trend with 367 complaints classified as Lack of Effect, which caused this complaint type to exceed your trend limit. B. Hydromorphone HCl Injection USP, 10 mg/mL Nial, for the review period 6/11/2016 to 6/10/2017 you identified your visual inspection process as a root cause and you failed to incorporate corrective and preventive action. REPEAT OBSERVATION from 4/23/2014 and 6/8/2016
- Observation 8
Deficient complaint handling procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written. Specifically, Your complaint handling procedure does not require you to procure the lot number from your customer in the event it is not provided at initial intake. You have received approximately 285 complaints without a lot number of approximately 1510 total complaints received. This represents approximately 20% of all complaints. Products which represent this process include but are not limited to Glatopa/Glatiramer Acetate Injection, (b)(5) (4) Injection, Makena/HydroxyProgesterone Injection, Epinephrine Injection, etc.
- Observation 9
Sterility testing deviations not recorded
Deviations from written test procedures are not recorded and/or justified. Specifically, during sterility testing on 10/19/2017, dynamic monitoring of the isolator conditions during testing was not observed. SOP QC0695.40, Environmental Monitoring Inside the (b)(4) Isolator, requires that contact plates are taken (b)(4) and a viable air sample is taken (b)(4). (b)(4)
- Observation 10
Improper storage temperature controls
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected. Specifically, A. You currently store raw materials and equipment which list temperature storage requirements on their labels in your In-coming Warehouse which is not temperature and humidity controlled. For example, Mannitol lot no. 1 (b)(4) was observed in the warehouse which is used to manufacture over 9 sterile injectable products. The label on this product had temperature storage requirement of R (b)(4) degree Celsius. B. There is a temperature recorder located in the In-coming warehouse which is not always monitored and reviewed in accordance to your SOP no. QC0877.00 "Monitoring of Recorders". In addition, you have not performed a temperature mapping study of this area.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDevices · Compliance: DevicesPosted 483 · 14 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Investigations not extended to related lots
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. Specifically, A) Despite performing an investigation with a root cause implicating an entire product line and finding widespread impact across the line during numerous retention sample reviews, you did not expand your investigation beyond individual lots to the whole line: On 2/12/15, you received a complaint of multiple label defects (missing label, double labels, and peeling label) for Diltiazem ADD-Vantage Vial lot 39105DD, and you determined the primary root cause of the defects was the use of label adhesive that was optimal for glass vial adhesion but not for plastic vials. This label adhesive was used for your six ADD-Vantage products, all of which use plastic vials: - Diltiazem HCl 100 mg/vial; - Erythrocin Lactobionate-I.V. 500 mg/vial; - Sterile Vancomycin HCl, USP 750 mg/vial; - Vancomycin HCl for Injection, USP 500 mg/vial; - Vancomycin HCl for Injection 1 g/vial; and - Azithromycin for Injection, USP 500 mg/vial. You did not consider and evaluate the impact on these other ADD-Vantage products and, at the time the investigation was closed on 4/22/15, approximately (b) (4) still-unexpired lots were on the market. You received additional complaints and conducted a review of retention samples as follows: - Azithromycin USP lot 49335DD exam on 4/20/15 (148 labels defective out of (b) (4)) - Vancomycin 1 g/vial lot 46240DD exam on 4/20/15 (51 labels defective out of (b) (4)) - Vancomycin 1 g/vial lot 49170DD exam on 4/20/15 (55 labels defective out of (b) (4)) - Vancomycin 1 g/vial lot 49245DD exam on 4/20/15 (80 labels defective out of (b) (4)) - Diltiazem lot 47385DD exam on 4/20/15 (30 labels defective out of (b) (4)) - Diltiazem lot 48045DD exam on 4/20/15 (81 labels defective out of (b) (4)) - Diltiazem lot 50075DD exam on 5/18/15 (120 labels defective out of (b) (4)) - Diltiazem lot 51305DD exam on 6/25/15 (10 labels defective out of (b) (4)) Despite multiple complaints and the high defect rates repeatedly discovered during retention sample review, the investigation was still not expanded to cover all ADD-Vantage products. You did not examine and investigate all ADD-Vantage products to determine the full extent of the problem. (b) (4) During the FDA inspection we examined approximately (b) (4) unexpired retain samples including Vancomycin lots 44170DD, 49325DD and 50235DD; Diltiazem lots 41160DD, 47385DD and 51305DD; and Azithromycin lot 49335DD. Of those units, approximately 96% were defective and 60% had a complete gap between the bottle and label for the entire vertical length of at least one side of the label.
- Observation 2
Reserve samples not adequately examined
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, Your reserve sample selection criteria, as well as your sample inspection procedures and practices are inadequate as demonstrated by their inability to detect the pervasive label degradation in the ADD-Vantage line of products discussed above in Observation 1. In 2015, approximately (b) (4) lots of ADD-Vantage products were selected for annual visual review to represent all ADD-Vantage products, but you did not discover or document any degradation: A) Your firm does not inspect reserve samples on a yearly basis for all types of degradation, such as visible label adhesive degradation and particulates caused by degradation. Per SOP QC0801.30, you only examine reserve samples for: 1) (b) (4) deterioration, 2) appearance for (b) (4), and 3) (b) (4). Your SOP (standard operating procedure) is inadequate because it does not require employees to look for all types of degradation. B) You do not use acceptable statistical procedures to select units for yearly examination which resulted in significant under-examination of reserve samples. Per SOP QC0801.30, you perform annual examination on approximately (b) (4) batches for each product code. However, of the batches selected for examination, you do not examine all units in the reserve sample for that batch, and you only inspect up to a maximum of (b) (4) units total. You arrived at this number by improperly applying ANSI-ASQ Z1.4-2003/MIL-STD-105E by basing the calculation on the (b) (4). As a result, you inspect (b) (4) units in a batch as large as (b) (4) units (which itself is intended to be representative of approximately (b) (4) total batches, the other of which are not examined). Therefore, for your high volume products, this means you examine (b) (4) units to represent approximately (b) (4) units on the market. In 2015, the reserve criteria/procedures/practices discussed above were used for all of the approximately (b) (4) batches / (b) (4) million units you manufactured.
Show observations 3 to 14
- Observation 3
Field Alerts not filed timely
An FDA Field Alert was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application. Specifically, A. You received complaints and performed retention sample evaluations between 4/20/15 and 6/25/15 showing at least (b) (4) different lots of different products had significant label deterioration. (b) (4) Approximately (b) (4) lots were impacted by the root cause of the issue. You did not file a field alert notifying the district. B. Your Field Alert practices and SOPs for quality defects reported did not include reporting requirements to FDA for products distributed outside of the United States (i.e. internationally). C. A complaint for Ketoralac Tromethamine Injection 30 mg/mL Vials, lot no. 46205DD was received reporting particulates observed in vials. Complaint no. 3018231, registration date 9/22/15, documents this complaint was received by Regulatory Affairs Operations Specialist GCM on 9/16/15. This complaint investigation also documents GCM received another notification of the complaint from FDA with MSB # 2015-06906 on 9/21/15. On 9/22/15, during the investigation and evaluation of their retention samples, you found (b) (4) units out of the (b) (4) also contained particulate matter (PM). You did not file the Initial Field Alert until 9/24/15. D. You received four complaints on Dobutamine Inj. USP, 12.5 mg/mL, 20 mL in 20 mL vials, lot no. 52175DD, which reported the product was "discolored". These complaints were received on 1/12/15, 2/25/15, 3/08/15 and 3/09/15 before you initiated a Field Alert on 3/10/16, as follows: 1. Complaint no. 3139049 was received on 1/12/16 for a discolored solution described as a "dingy champagne color". 2. Complaint no. 3189961 was received 2/25/16 for "4 vials that are discolored". 3. Complaint no. 3205537 was received 3/08/15 for product reported to be a "peachy color and have not seen it that way". This complaint also reported the vial contained "Chunks of floating in there little flakes, like eraser dust." 4. Complaint no. 3207686 was received on 3/09/15 reported eight vials "rapidly changed from clear colorless solution to a dark color pink after a week." E. On 3/18/16, a Manufacturing Quality associate identified a critical container defect in the (b) (4) Area, during the manufacturing operations for Precedex (Dexmedetomidine HCl Injection) 4 mcg/mL, 100 mL in 100 mL vial, lot no. 63075DD. This (b) (4) (b) (4) involved over (b) (4) lots of product with at least (b) (4) of them being rejected and potentially affected product being in distribution. The Initial Field Alert was not filed until 4/13/16. F. On 12/31/15, Regulatory Affairs Operations Specialist GCM, received an email regarding a complaint (no. 3129061) on Vancomycin Hydrochloride for Injection, lot no. 565003A. The complaint reports a vial containing particulates which "looks like a small insect or speck of dust". On 1/08/16, you performed an examination of reconstituted reserve units and found one unit, which confirmed this complaint. The Initial Field Alert was not filed until 1/08/16. G. The following Vancomycin Hydrochloride particulate complaints were also received for this lot 565003A, which you tested and identified as "cardboard": 1. Complaint no. 3188939 was reported on 2/24/16 for particulates which reported "a piece of cardboard particulate was found floating in the vial". You did not file a Field Alert within three working days of receipt of this complaint information. 2. Complaint no. 3256909 was reported on 4/15/16, which was described a floater which looked like a brown paper towel or corrugated paper. You did not file a Field Alert within three working days of receipt of this complaint information.
- Observation 4
Failure to recognize trends and extend investigations
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A. You did not recognize trends and repeat deviations and you did not initiate effectiveness plans or provide adequate justification for an exemption, as required by your SOP QC0215.03: (b) (4) (b) (4) (b) (4) 1. In 2015, for (b) (4), you identified (b) (4)-related failures which caused (b) (4) excursions (impacting different lyophilizer runs/lots of product), all of which resulted in critical process parameters not being met. You did not recognize this as a trend by the end of your final investigation closing on 11/24/15. (b) (4) (b) (4) Beginning in January 2015, you saw (b) (4) lots of product impacted by (b) (4) excursions that caused critical process parameters not to be met, but you did not put into place any effectiveness checks: (b) (4) From July-October 2015, more lots were affected by excursions which caused critical process parameters not to be met, and they were all caused by an identical control module: - ER 234614: On 7/30/15, during production (b) (4), a failure in the (b) (4) occurred. The unit was replaced and no effectiveness check was put in place. - ER246191: On 10/27/15, during production of Vancomycin lot 58310DD, a failure occurred. At the time, the cause was believed to be the failure of a (b) (4) on the (b) (4), and the (b) (4). No official investigation was opened at this time and you continued to manufacture. No effectiveness check was put into place. - ER246191: On 10/29/15, during production of Vancomycin lot 58320DD, another failure occurred. An investigation was opened but the lyophilizer remained in use. No immediate corrective action was taken. - ER246191: On 10/31/15, during the production of Vancomycin lot 58326DD, another failure occurred. The investigation above was expanded to include this deviation and found the (b) (4) had failed, causing the all excursions on 10/27/15, 10/29/15, and 10/31/15. However, the investigation did not recognize the failures from 10/27/15-10/31/15 were caused by the same (b) (4) that failed on 7/30/15. (b) (4) (b) (4) Despite the lots impacted by (b) (4) excursions in the last year, and the last being caused by an identical part, your final investigation (ER246191) stated there was no trend or repeat failure. No effectiveness check was ever put into place. 2. As noted in Observation 1, you had numerous complaints of the same label defect. Your only investigation (ER 214194, closed 4/22/15) stated there was no repeat occurrence of this issue. Additionally, you did not put in place an effectiveness check. B. During the investigation of your Vancomycin Hydrochloride for Injection, USP, involving complaints received for particulates from cardboard, you did not extend your investigation to review other distributed lots. After your evaluation of the retain sample for lot no. 565003A where you identified a unit which contained fibrous particles, you did not evaluate other retain samples. In addition, your Risk Assessment Register (RAR) #991 dated 02/12/16, you did not include information regarding an additional complaint no. 3133219 which was received on 1/6/2016. This Vancomycin Hydrochloride for Injection, USP, lot no. 421503A (Canada), was reported to have particulates which were also found to be cardboard.
- Observation 5
Investigations lack conclusions and follow-up
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Specifically, A. In your Annual Product Reviews for the following products you identify label defects but fail to initiate appropriate corrective and preventive actions to address and correct this failure: 1. Diltiazem HCl Inj. 100 mg/Vial, ADD-Vantage, for the review period of 12/18/2014 to 12/17/2015: You identified a trend for labeling complaints through an investigation and determined to be due to the incorrect adhesive used on labels with plastic vials. 2. Vancomycin HCl, USP, 1 g, vial, ADD-Vantage, for the review period of 7/02/2014 to 7/01/2015: You report three complaints were received for "misplaced labeling". You document "A visual retains evaluation was performed with multiple units with varying degrees of label flagging identified." "All the complaints were confirmed as manufacturing related." B. Five complaints for Dobutamine Inj., 12.5 mg/mL, 20 mL in 20 mL Vial product, lot no. 52175DD were received between 1/13/16 through 4/27/16. These complaints reported product which was discolored and/or contained particulates. As of 5/25/16, you have not completed an investigation identifying the cause of this complaint and/or initiated a corrective and preventive action to address this product specification failure.
- Observation 6
Major device design change not notified
You did not notify the agency of the changes in a drug product container closure system that controls the drug product delivered to a patient or changes in the type (e.g., glass to (b) (4), vial to syringe) or composition (e.g., (b) (4) to another (b) (4)) of a packaging component that may affect the impurity profile of the drug product. Specifically, you did not properly notify the agency of a major design changes in the drug delivery system, iSecure, a class II device for the following drugs: Product Type Code / Product Description / Produc List Submission Date / Submission Type / Submission Number / Submission Date / Manufact. Release Number / Lot : iSecure Version 2 Hydromorphone 200-403 29-04-10 Original NDA L 25540L (b) (4) 29-04-10 Original NDA L 25600L (b) (4) 29-04-10 Original NDA L 20550L (b) (4) Morphine Sulfate 202-515 14-01-11 Original NDA L 41560L 14-01-11 Original NDA L 40720L 14-01-11 Original NDA L 34750L 14-01-11 Original NDA L 32590L Ketorolac 74-993 3-09-10 PAS L 30720L Midazolam 75-856 6-Aug-10 Annual Report 7-Dec-11 CBE-0 L 91710L Ondansetron (b) (4) CBE-30 (b) (4) 10-01-11 1 1 7695L In May, 2009, you completed a major design change in the drug delivery system from iSecure 1, a class II device to iSecure 2. You did not properly notify the agency of the design changes for iSecure 1, and the above listed drugs are currently manufactured and shipped in iSecure 2 drug delivery system. The above drug applications referenced Hospira's 510(k) clearance for iSecure 1 as the drug delivery system, while you manufactured and assembled the products in iSecure 2 devices.
- Observation 721 CFR 820
DHF missing design change documentation
The design history file does not demonstrate that the design was developed following the requirements of 21 CFR 820. Specifically, you did not establish and maintain a design history file for each type of device. You did not document design changes in DHF (Design History File) for a major design change in a class II device. iSecure, a class II device, was approved in 2006 for use in the withdrawal and administration of sterile materials under aseptic conditions. In 08/01/2008, your firm initiated a design change for iSecure that included new delivery sizes (1.5 mL, 2.5 mL and 5.0 mL), materials, packaging and instruction for use. No design changes were documented in DHF prior to initiation of the new product design. As of 05/27/2016, the redesigned device, "iSecure 2" is used for withdrawal and administration of sterile materials under aseptic conditions for the following drug products: • Hydromorphone HCl Inj. USP (1 mg/mL, 0.5 mL in 1.5 mL cartridge, 1 mg/mL, 1 mL in 1.5 mL cartridge and 2 mg/mL, 1 mL in 1.5 mL cartridge) • Morphine Sulfate Inj. USP (2 mg/mL, 1 mL in 1.5 mL cartridge, 4 mg/mL, 1 mL in 1.5 mL cartridge, 8 mg/mL, 1 mL in 1.5 mL cartridge, 10 mg/mL, 1 mL in 1.5 mL cartridge and 15 mg/mL, 1 mL in 1.5 mL cartridge) • Ketorolac Tromethamine Inj. USP (30 mg/mL, 1 mL in 1.5 mL cartridge) • Midazolam HCl Inj. USP (1 mg base/mL, 2 mL in 2.5 mL cartridge) • Ondansetron Inj. USP (2 mg/mL, 2 mL in 2.5 mL cartridge).
- Observation 8
Acceptance status not identified
The acceptance status of product was not identified to indicate conformance or nonconformance with acceptance criteria. Specifically, you did not identify by suitable means, the acceptance status of product, to indicate the conformance or nonconformance with acceptance criteria. You did not perform final acceptance activities for iSecure 2, a class II device to assure the device is functioning as intended. iSecure 2 is used in the withdrawal and administration of sterile drug materials under aseptic conditions. During the walk-through of manufacturing (filling line) and packaging ((b) (4)) on May 17th 2016, an FDA investigator observed manufacturing and packaging of Hydromorphone HCl Inj. USP 1 mg/mL, lot no. 64560LL. The FDA investigator observed Hydromorphone HCl Inj. USP 1 mg/mL, lot no. 64560LL were being placed in iSecure 2 and prepared for shipment. Device functionality test was not conducted to ensure the device is functioning as intended.
- Observation 9
Aseptic procedures not followed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, A non-sterile surface was introduced for use in the (b) (4), which is prohibited by your SOPs: On 5/21/16, while Hydromorphone lot 651903A was being manufactured in the (b) (4), a bottle of (b) (4) tamper resistant seal was observed in the (b) (4). Inserting bottles with tamper seals is specifically prohibited by your procedure MF0732.00. According to your records, a (b) (4) was originally loaded into the (b) (4) on 5/19/16 by a (b) (4). A surface sterilization cycle was run, but due to a separate manufacturing issue, the (b) (4) were unloaded into the grade D area. Later on 5/19/16, a (b) (4) from the grade D area [was moved] into the (b) (4). The (b) (4) on 5/20/16, and then the (b) (4) was opened and operators began using the items inside. On 5/21/16, our inspection discovered the (b) (4) (b) (4). You do not know whether the (b) (4) was improperly loaded and placed/verified by (b) (4) or if the error only encompasses the (b) (4) operators.
- Observation 10
In-process limits not established
In-process specifications are not consistent with drug product final specifications, derived from previous acceptable process average and process variability estimates where possible or determined by the application of suitable statistical procedures where appropriate. A. You currently have no in-process defect alert (and/or action) limits for either your semi-automated vial inspection process or your fully-automated vial inspection process despite the approximately 175 particulate complaints you have received since your visual inspection remediation process began in response to the January 2012 FDA inspection. The following (b) (4) applies to the approximately (b) (4) products which you visually inspect, such as Precedex, Marcaine HCl, Hydromorphone, Diltiazem, and (b) (4): Whenever any change is made to your manufacturing process (including a change to your visual inspection program) you completely remove the in-process defect limits for approximately (b) (4) of that product. During this time, your SOP QC1310.10 directs you not to investigate any batches despite any number of defects found during inspection. You have reset (i.e. eliminated) your defect limit multiple times since 3/25/15 and plan to continue this practice in the future: - On 3/25/15, you began using fully-automated visual inspection and have moved approximately (b) (4) different products to this process (and inspected approximately (b) (4) different batches) without any defect limit. You will inspect approximately (b) (4) batches until limits are in place. On 1/11/16, you changed certain defect categories for your semi-automated visual inspection, (b) (4) resulting in another reset/elimination of your limits on (b) (4) products, of which you have already inspected (b) (4) batches without any defect limits in place. Until fully implemented, this will result in approximately (b) (4) batches being inspected without limits. As part of your visual inspection remediation plan made in response to the January 2012 FDA inspection, you are still in the process of moving approximately (b) (4) more products to fully automated inspection, which will result in another defect limit elimination for those products affecting another approximately (b) (4) batches in the future. You plan to remove the semi-automated (b) (4) from the beginning of your process, which (per your current procedure/practice) will result in up to another approximately (b) (4) batches inspected without defect limits in the future. Although you have past defect rate data on all of your vial products (which, per your defect mapping, can be directly applied to your current defect categories), you have not used that to set appropriate limits for your current inspection process. (b) (4) B. In addition, for the (b) (4) Injectable product manufactured at your site, you received numerous complaints for particulates which were identified as (b) (4). In the Investigation Summary Section of the complaint investigation you document "there are no accept/reject limits for the (b) (4)" for this (b) (4) check. The following complaints also include quality defects reported on (b) (4) product which was processed through your (b) (4) and Semi-Automated Visual Inspection System. You document in these investigations "there are no accept/reject limits" for defects identified at these stations. 1. Complaint no. 3082386, Registration Date: 11/14/15: Ten percent of the defects which are undefined are evaluated and found the following: two glass particles, eight fiber particle, fifty-six red particle, two components particles, fifteen other particles, one plunger foreign substance stain product contact, and one plunger (b) (4). 2. Complaint no. 2772497, Registration Date: 2/26/15: Ten percent of the defects which are undefined are evaluated and found the following: ten units with glass particle, thirteen units with fiber particles, forty-seven units with red particles, thirteen units with other particles, one unit Glass: Foreign
Shortened here; the PDF has the full text.
- Observation 11
Rejected materials not quarantined or tracked
Rejected in-process materials are not controlled under a quarantine system to prevent their use in manufacturing or processing operations for which they are unsuitable. Specifically, A) Your SOP for semi-automated visual inspection of vials (SOP MF0502.00) allows rejected units (b) (4) to be re-inspected and included with the other acceptable units. It states: "VIII. SEGREGATING AND RECORDING REJECTS A. All units that have been inspected (b) (4) to confirm reject status. This procedure (b) (4). Any units that are considered acceptable will be included with the other acceptable units from the lot." There are no records for any of your products showing how many units have been subject to this procedure and the re-inspection results. B) You do not keep attributable records of defects found by (b) (4) during semi-automated visual inspection. You perform visual inspection (b) (4). Visual inspectors (b) (4) which tracks each type of defect (b) (4) found, but no record is kept of how many defects were found by each inspector. (b) (4).
- Observation 12
Original electronic data not retained
A written record of the program along with appropriate validation data has not been maintained in situations where (b) (4). Specifically, Original quality data is not maintained when it is eliminated by your computerized (b) (4). You use (b) (4) for the aseptic fill and packaging lines. The electronic data (b) (4) from these (b) (4) is not documented, recorded, or saved. This directly impacted investigations into Exception Report 262824 and 255648 when the (b) (4) to the capping line was turned off accidentally. You were unable to track the electronic data back to see who performed what commands (b) (4) via the (b) (4) or when it occurred, because the (b) (4) for rooms and (b) (4). The (b) (4) is designed to (b) (4).
- Observation 13
Procedures not followed during production
Written production and process control procedures are not followed in the execution of production and process control functions. Specifically, (b) (4) On 5/18/16 we observed employees use (b) (4), write on some paperwork, and then (b) (4) perform personnel touch plates on line (b) (4), when Nimbex NX20, lot 65105DD, was being aseptically filled. On 5/19/16 we observed an employee use (b) (4) immediately before performing (b) (4) personnel touch plates on line when Vancomycin M-6535, lot 65090DD, was being aseptically filled.
- Observation 14
Nonconforming label materials accepted
Labeling or packaging materials which did not meet written specifications were not rejected to prevent their use in operations for which they are unsuitable. Specifically, (b) (4) All batches of incoming ADD-Vantage labeling from 7/3/2013 until 4/9/2015 were accepted for use despite not meeting internal specifications outlined in Monograph Y-011, even though the Certificate of Conformance for each of these batches specifically listed the wrong adhesive.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic gowning and traffic
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, the design of the personnel entryways, personnel and material traffic flows and gowning practices, particularly with regard to dedicated plant uniforms, captive plant shoes and shoe covers, is deficient. The current [illegible] promotes the propagation of microbial contamination. The following was observed during the inspection 09 OCT - 24 OCT 2012 and has been the current practice for approximately one (1) year. This is applicable to all drug products, over approximately two hundred drug product combinations of strengths and dosage configurations. Aseptic filling personnel were observed to frequent common public areas such as administrative offices, the warehouse, and the cafeteria without being required to change out of dedicated plant shoes which then were worn back into aseptic fill rooms under their aseptic gowning. Employees and visitors wearing shoes which are worn outside the facility must don shoe covers in manufacturing corridors and hallways. However, employees in dedicated plant shoes were seen coming from the warehouses, and in the cafeteria, commingling with personnel wearing outside shoes then returning to the plant manufacturing areas for work. There is no distinction in these practices other than a [illegible] sanitization step required [illegible] of all employees in dedicated shoes. This sanitization is negated as soon as employees return to common hallways and public areas of the plant. This is a failure to mitigate the ingress of dirt, debris and microorganisms. For June, July and August of 2011 and 2012 there was an increase over action limit trending guidelines used by the firm for the presence of microorganisms in environmental monitoring data which represents a seasonal increase in the recovery of vegetative organisms.
- Observation 2
Investigations not extended facility-wide
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy. Specifically, 1. Since March 2012 your firm has discovered 2 lots [illegible] of Fentanyl Citrate for injection which failed HPLC stability time point analysis for total impurities. Subsequent investigation of the failures [illegible] were due to extractables from the rubber plunger. In addition, under study your firm tested [illegible] lots of Fentanyl Citrate from retain samples and determined one additional failed for total impurities and 2 others were at the USP limit. There are [illegible] lots of Fentanyl Citrate currently distributed and unexpired; your investigation was not expanded to comprehensively determine the number of lots which fail USP specifications. 2. There were 2 incidents within the past 2 months of city water leaking from sprinkler heads located in your aseptic areas; these sprinkler heads and piping had been replaced by your contractor during a recent shutdown. • Incident PRID: 95301 occurred 17 Aug 2012 near lyophilizer [illegible] (room 335, 335B) during the unloading of [illegible] drug product. The root cause of the leak was attributed to the tapering of the threading between the piping and the reducer; the pipes did not fit each other correctly. • Incident PRID: 95564 occurred 20 Aug 2012 in the SPA corridor near the entrance door to the [illegible] filling suite during filling of Diphenhydramine. The root cause was attributed to the pipe fitting seal on the sprinkler system plumbing. Although in each case the event was contained, and drug product was not affected, neither investigation extended to other wet sprinkler heads throughout the facility to adequately evaluate if they had been properly installed, or could be leaking.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesPosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unvalidated visual inspection process
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, Your firm has not validated the EvoVision light inspection testing with regard to personnel qualification, inspection speeds and technique to include using a seeded filled lyophilized vials on manufacturing. These lines are used to manufacture drug products including but not limited to Marcaine HCl (Bupivacaine), Demerol HCl Inj (Meperidine), Morphine Sulfate Inj, Heparin Lock Flush Solution USP, Humalog 100 (human recombinant insulin), Fabrazyme (agalsidase beta) and Vancomycin HCl. Procedure QPO.15.CL04 Visible Particulate Procedure (effective 05/15/[illegible]) page 2 of 7 states "Requirements" and describes the manufacturing inspection process "***Parenteral products must be inspected in-process for visible particulate.***" page 3 of 7 under Examination states "*** (b)(4) ***". On 11/30/11 we witnessed EvoVision inspection on line [illegible] and [illegible] for Epinephrine Inj. USP, 1:1000, 1 mL Ampuls lot 112653A; [illegible] line Morphine Sulfate Inj. USP 2 mg/mL ImLin 2.5 mL Carpuject, lot 11845LL; and inspection of lyophilized Vancomycin HCl for Injection, USP, 1 g, 20 mL in 25 mL vial, lot 11206DD. We observed: • There is no inversion of any vial, ampul or cartridge to facilitate particulate inspection. • For Carpuject configurations employees were viewed inspecting units for about [illegible] seconds by taking approximately [illegible] inches of vertically positioned cartridges (target outer diameter [illegible]) at one time, rolling them back and forth to assess the units before continuing to a new set. This is estimated to account for [illegible] inspected at once which over the span of [illegible] minute approximates [illegible] units inspected in [illegible] seconds. • Training Course Plan PKT0215.02 details objectives and requirements of training. The course plan and those for ampuls and lyophilized product do not include the use of a seeded qualification panel (known defects inserted into a sample lot of "good" product to assess the trainee's aptitude in finding defects). A seeded qualification panel assures the inspection process is adequate to detect particulate matter, glass particulate, seals, proper stopper and plunger placement etc. • Vision inspection employees performing inspection of lyophilized product verbally stated they do not inspect the top of the lyophilized cake. Semi-automated vision system equipment is not set up to facilitate inspection of the top of the cake, only the top of the flip top cap.
- Observation 2
Inadequate aseptic gowning and EM practices
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written. Specifically, The design of the personnel entryway, personnel and material traffic flow, and gowning practices promotes the propagation of microbial contamination. The following was observed during the entirety of the inspection 11/28/11-1/4/12. This is applicable to all drug products, different pharmaceutical configurations. Procedure MFO101.01 General Rules and Regulations: Aseptic Areas (effective Dec 16 2011) states "... McPherson Aseptic Manufacturing areas are the most critical manufacturing locations in our site operations." Training Course Plan PRTO106 attachment 2 under Importance of Correct Gowning (bullet 2) states "***Protecting the product from particulate and microbial contamination.***" Dedicated plant clothing is intended to mitigate the ingress of dirt, debris and microorganisms into the cleaner areas of the plant. However, it was observed aseptic filling room personnel are allowed to frequent common public areas such as administrative offices, restrooms, and the cafeteria without being required to change out of dedicated plant scrubs and shoes which are then worn back into aseptic fill rooms under aseptic gowning. There is common interaction and mingling of personnel in street clothing and those performing manufacturing in the aseptic core. Failure to mitigate the ingress of dirt, debris and microorganisms is exampled by: • Men and women's locker rooms and personal area required to don factory attire and factory dedicated shoes prior to entering into the manufacturing areas is not delineated to avoid cross contamination of street clothing to factory clothing. Lockers where street clothing/shoes and plant shoes are kept are shared. • There is no record or document which dictates factory shoes are cleaned/sanitized on a routine basis. • Aseptic personnel are required to don factory attire and dedicated shoes used to reduce the ingress and presence of objectionable microorganisms yet employees can and do access the production staging warehouse, cafeteria, restrooms and office corridors which are uncontrolled environments. • Aseptic personnel are required to don a disposable lab coat prior to entering the cafeteria in order to protect their plant uniform. However, the disposable coats can be reused up to [illegible] days. Media Fills and environmental monitoring show: • Gram positive spore forming bacillus species (soil born microorganisms) have been recovered 158 times from Grade A and Grade B areas in 2011. In addition, there have been 170 above action level findings on three (3) filling line rooms, and [illegible] since November 2010. None of the 10 exception reports reviewed identified a root cause for the presence of microorganisms. • The men and women locker rooms are not included in the Environmental Monitoring (EM) Program; the pre gowning rooms have not been sampled on the entry side of the demarcation line to determine the presence or absence of objectionable microorganisms (e.g., spore forming bacillus species) and the microbiology department has not taken into consideration whether these gown rooms could be a source and/or root cause for the bacillus microbial contamination. • The environmental monitoring carts are not included during routine monitoring of ancillary equipment in the sterile corridors. • There were 2 unacceptable media fills for 2010 and 2011 which includes a microbial failure and a growth promotion failure. For the same time frame there were 5 hits in which positive vial(s) were identified. • For the [illegible] media fill failure, conducted 7/13/2011 Alternaria alternate, Curtobacterium species, Staphylococcus epidermidis, Micrococcus terreus and Arthrobacter species were recovered. Sup-1 EM data from the same time frame as the media fill similarly identified Alternaria alternate in the [illegible] room, [illegible] component preparation room, the SP
Shortened here; the PDF has the full text.
Show observations 3 to 6
- Observation 3
Unvalidated glass supplier analyses
Establishment of the reliability of the container supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals. Specifically, Your firm has not qualified the process of tailgating (pre-delivered/pre-pulled samples by the glass vendor) glass container samples. Verification of accuracy from the vendor against glass container samples collected in house has not been performed. This applies to (and includes but is not limited to) glass components used in the manufacture of Fabrazyme (agalsidase beta), Epinephrine, Hydromorphone HCl, Heparin, Vancomycin HCl, Marcaine HCl (Bupivacaine), and Morphine Sulfate. These vendor pulled samples are used for qualifying a lot of glass for use in lieu of internally pulled samples. These samples are used to assure an accurate, representative, statistically valid lot of glass, to be released and used in production, meets specifications. SOP QC0900.04 Pre-Delivered Samples and Tailgate Samples effective 9/09/2005 and SOP [illegible] effective 11/18/2011 state "... never term would actually comprise when assessing the relevance of a sample pulled to represent [illegible]." Further, you have not established the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. Verification of the component specifications to the vendor's release specifications (vendor glass certification and testing) is not performed to assess annealing, lehring, shoulder angle and glass thickness at critical areas with specific respect the Carpuject configuration. Glass components have not been microscopically examined. A recall was initiated on 7/8/2011 for Carpuject iSecure configurations due to cracks/breaks found in the glass cartridges including Midazolam Inj. USP, Heparin Sodium Inj. USP, Ketorolac Tromethamine Inj. USP, Ondansetron Inj. USP, Diazepam Inj. USP.
- Observation 4
Stability room humidity monitoring failures
Test devices are deficient in that instruments, apparatus, gauges, and recording devices not meeting established specifications are used. Specifically, The alarms for the probes in the walk-in [illegible] stability room, containing all uncontrolled drug products held for stability testing, were turned off after 10/22/2008. The humidity was out of specification on 6 different occasions after 10/22/2008 through 7/8/2011. There were 4 above humidity events and 2 below humidity events. The longest events lasted from 5/19/2011 to 7/8/2011. This recorder is checked daily by Manufacturing Quality personnel but they only looked for an alarm they did not look at the actual readings. Date / Date Range Length of Excursion Reason for Excursion 18-20 JUL 2009 37.5 hours 25-26 SEPT 2010 31 hours 28 SEPT 2010 11.5 hours 29-30 SEPT 2010 37 hours 30 DEC 2010 8 hours 19 MAY - 8 JUL 2011 400 hours (50 days) Further, humidity is only checked in the middle of the room during requalifications of the [illegible] CORR stability room M732. You have not verified the humidity is uniform throughout the entire room by mapping humidity in the corners of the room during requalification.
- Observation 5
Nonrepresentative smoke studies and air control
Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production Specifically, Smoke studies are not representative of actual production practices which assess whether or not appropriate air changes and laminar air flow exists and can be maintained in a Grade A filling area. On 12/2/2011 I observed an intervention on the [illegible] line at the needle assembly hopper during the filling of Labetalol HCl Inj. USP 5 mg/mL lot [illegible]. The hopper was vibrating to move the assemblies into position. The operator opened the door and removed multiple assemblies using forceps. The intervention lasted for more than 20 seconds. The smoke study for this type of intervention did not have the hopper vibrating and the operator opened the door removed one assembly and closed the door in approximately 10 seconds. During the smoke study, I observed smoke beginning to enter into the hopper area before the operator closed the door. The firm did not have data to support longer interventions similar to those observed and there were no interventions demonstrating the vibrating hopper. The smoke studies do not include the effect upon room pressure and laminar air flow when doors are opened to the sterile corridor simulating personnel and materials movement into and out of the aseptic filling room. Additionally, environmental monitoring activities are not routinely included in the smoke studies.
- Observation 6
Insufficient reserve sample review procedures
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, During the annual review of the reserve samples as well as for any reviews conducted as part of a complaint investigation, quality employees are required to assess the reserve samples to determine if the product in question meets visual specification. It was determined product specifications are not used in this examination. When asked how the employee knows what product is supposed to look like, the response was the employees are very familiar with the product. It was not verbally stated a finished product monograph is ever consulted during this review. These procedures are similar for approximately [illegible] different product configurations manufactured in 2011 for this site.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Mar 10, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- May 11, 2026FDA-FOIA-2026-4853Form 483· 1 of 5 sitesRecords released
Inspection ending Jan 17, 2025VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 14, 2025FDA-FOIA-2025-8626Form 483· 1 of 3 sitesWithdrawn
- Jun 12, 2025FDA-FOIA-2025-7449Form 483· 1 of 9 sitesWithdrawn
Inspection ending Jun 30, 2023
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-7270Form 483Closed
Inspection ending Jan 17, 2020VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Mar 5, 2021FDA-FOIA-2021-1507Inspection recordsClosed
Inspection date not given
1 request.
- Feb 1, 2019FDA-FOIA-2019-635Form 483Open
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 18 inspections, with how many of them cited each.
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 2
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.186Master production and control records1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1925262, one row per refused product line.
1 refusal on 2026-04-14 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2026-04-14
MECASERMIN RECOMBINANT58HAY01
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-1355997-5/10001/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Hospira, Inc.D-U-N-S 141588017
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Hospira, Inc. (D-U-N-S 141588017) as the registrant for this site and the 6 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Hospira, Inc.Rocky Mount, North Carolina · FEI 102134312 inspections12latestFeb 7, 2025NAI2 warning letters, latest Mar 7, 2014
- Pfizer Healthcare India Private LimitedVisakhapatnam, India · FEI 30083160857 inspections7latestOct 18, 2022VAI1 warning letter, Mar 25, 2020
- Hospira Australia Pty LtdMulgrave, Australia · FEI 30011749296 inspections6latestSep 2, 2022VAI1 warning letter, Sep 26, 2014
- Hospira Worldwide, LLCPleasant Prairie, Wisconsin · FEI 30055647676 inspections6latestDec 16, 2025NAINone on file
- Hospira Zagreb d.o.o.Brdovec, Croatia · FEI 30106302875 inspections5latestJul 23, 2024VAINone on file
- Zydus Hospira Oncology Private LimitedAhmedabad, India · FEI 30078696195 inspections5latestJun 30, 2023VAINone on file
Other FEIs recorded as Hospira, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Hospira, Inc.FEI 3004591926Lake Forest, Illinois, United States
Last inspected 2025-08-22NAI
Hospira, Inc.FEI 1048698Clayton, North Carolina, United States
Last inspected 2013-06-13NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1925262 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1925262. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.