Skip to content

Family Pharmacy of Statesville

3478 E Broad St, Statesville, North Carolina, United States

FEI 3015859129

FDA has 2 inspections on file for Family Pharmacy of Statesville in Statesville, North Carolina (FEI 3015859129), from 2020 to 2022. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2020–2022
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Poor material flow and wipe-down failures

      Your facility was operated in a way that permits poor flow of materials. Specifically, A. During the compounding of Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the (b) (4) and the supplies with sterile (b) (4) prior to introduction into ISO 5 BSC. B. Prior to and after compounding Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the sterile (b) (4) bottle prior to introduction into the ISO 5 BSC.

    2. Observation 2

      Insufficient disinfectant contact time in BSC

      Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, the sporicidal agent, (b) (4), that your firm uses to clean the surfaces inside of the ISO 5 BSC requires a (b) (4) contact time. Your technician stated that this product is used on an (b) (4) (b) (4) basis and left on the inside surface of the ISO 5 BSC to dry while he performs cleaning of the outside surfaces of the BSC then does a final wipe down inside with sterile (b) (4).

    Show observations 3 to 9
    1. Observation 3

      Media fills do not simulate worst-case operations

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse case activities and conditions that provide a challenge to aseptic operations. Specifically, the firm's (b) (4) media fill which mimics their high-risk infusion compound, Hydromorphone, was performed with (b) (4) IV bags of (b) (4) each for a total batch size of (b) (4). However, the firm's highest volume as seen on their (b) (4) batch log for this infusion compound is (b) (4). (REPEAT OBSERVATION)

    2. Observation 4

      No HEPA filter in ISO 8 storage area

      You did not have a HEPA filter over the area to which sterile product was exposed without any information to support that the components remained sterile throughout the storage period. Specifically, your firm states that the prescription laboratory room is classified as ISO 8 but there is no HEPA filter present. The (b) (4) glassware used in sterile processing are stored in this room.

    3. Observation 5

      Sterilization cycles not verified with endotoxin indicators

      The cycle parameters used for (b) (4) of materials used to prepare sterile injectable drug products were not verified using endotoxin indicators. Specifically, you do not use endotoxin indicators to ensure and verify that the temperature and time cycle used to sterilize and (b) (4) glassware is adequate. (REPEAT OBSERVATION)

    4. Observation 6

      Inadequate dynamic smoke studies for airflow

      Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area. Specifically, A. According to our interview with the pharmacy technicians, no equipment or supplies were present in the ISO 5 BSC and they did not simulate the worst case scenario compounding activities during the smoke studies. B. Your ISO 7 clean room was certified with both ISO 5 BSC turned on however, subsequent compounding and media fills were performed with (b) (4) hood running which could potentially impact the airflow.

    5. Observation 7

      Rust contamination in hazardous materials cabinet

      Non-microbial contamination was observed in your production area. Specifically, we observed what appeared to be rust inside the cabinet storing both hazardous bulk drug substances and hazardous chemicals. The bottom door hinges and the bottom shelf on this cabinet had visible rust shavings.

    6. Observation 8

      Equal pressure allows poor air influx

      Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, the pressure between the ISO 8 anteroom and ISO 7 clean room is kept the same possibly leading to lower quality ISO 8 air entering ISO 7 clean room every time the door is opened.

    7. Observation 9

      Non-cleanroom chair in ISO 7 cleanroom

      The ISO-classified processing areas had difficult to clean equipment. Specifically, your firm uses a non-cleanroom compliant metal folding chair in the ISO 7 cleanroom while working in the ISO 5 BSC.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No sporicidal cleaning in ISO 5

      Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, you did not have a sporicidal cleaning agent and your cleaning log does not indicate that a sporicidal cleaning agent has been used in your ISO 5 classified aseptic processing area. In addition to this, trending data indicates that on 7/30/2019 viable air sampling in your Chem hood (ISO 5) recovered 1 CFU of coagulase-negative Staphylococcus spp. and Clean Bench (ISO 5) recovered 1 CFU of Micrococcus/Kocuria spp. These hoods are used to produce sterile drug products for injection and intrathecal administration.

    2. Observation 2

      No endotoxin testing for intrathecal products

      You have no assurance that the endotoxin level of your intrathecal drug products is safe, since you do not have any endotoxin data and your firm doesn't perform endotoxin testing for the finished product. These preparations are made using non-sterile starting material. Furthermore, there is no endotoxin testing data for your API. Specifically you prepared morphine sulfate bupivacaine 20 mg/4 mg for intrathecal injection lot 01272020@6 and did not perform endotoxin testing. This was made using morphine sulfate USP [(o) (4)] lot [(6)-(4)-, and bupivacaine HCl USP lot [{o) (4i which are also not tested for endotoxin.

    Show observations 3 to 9
    1. Observation 3

      Nonsterile disinfectants/wipes in ISO 5

      Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, you did not use sterile [(6) (4) I to clean your ISO 5 Chemo hood on 2/5/2020 during the processing of hydromorphone HCl 2 mg/ml infusion lot 02052020@2 in 0.9% NaCl for injection. The spray bottle labeled to contain sterile [(6) (4) I lot [(o) ("1-) was expired on 10/19. It did not contain the [(6) (4) I listed on the label. It contained another supplier's sterile [(6) -(4)"1 with an unknown lot and expiration date. The reuse of spray bottles and sterile lint free wipes exposed to uncontrolled conditions such as the interior of the [(6) (4) with no HEPA filtration may compromise the sterile nature of this disinfection agent and wipes.

    2. Observation 4

      Poor air quality control into buffer area

      Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, A. The unclassified [(l:5)_ (4)l opens from an unclassified room to your ISO 7 buffer room. On 2/3/2020 and 2/5/2020 this (6) (4)J had visible dust on the [(6) (4) I which were difficult to clean and prone to dust collection. There was also observable dust in the uncontrolled room ceiling vent above this ~D) 4]. B. The ante-room where you gown before entering the ISO 7 buffer room has no HEPA air filtration.

    3. Observation 5

      Inadequate containment for hazardous drugs

      You produced hazardous drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination. Specifically, on 10/10/2019 you prepared the hazardous and potent sterile drug fluorouracil 10 mg/ml ophthalmic solution in 10 ml 0.9% preservative free NaCl in your sterile ISO 5 aseptic processing area.

    4. Observation 6

      Media fills not worst-case simulated

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst case activities and conditions that provide a challenge to aseptic operations.

    5. Observation 8

      Instruments not calibrated at intervals

      The calibration of instruments, apparatus, gages and recording devices is not done at suitable intervals in accordance with an established written program. Specifically, your scale used for the weighing of metronidazole USP, lidocaine HCl USP, and chlorpromazine HCl USP have not been calibrated [illegible]. This scale was used to determine these bulk drug substances in the following non-sterile drug products: 1. Metronidazole 4%, Lidocaine 5% topical ointment lots: •10232019@1 •12122019@6 •12092019@2 2. Chlorpromazine HCl 50 mg suppository lots: •01132020@2 •01172020@1

    6. Observation 9

      Air recirculation without dust control

      Air is recirculated to production areas, without adequate measures to control recirculation of dust. Specifically, your uncontrolled lab ceiling vent had visible dust and the filter alarm in your [(6) (~) I hood indicated that filters in this hood containing both scales needed to be changed. This area is where you prepare the following non-sterile drug products: 1. Metronidazole 4%, Lidocaine 5% topical ointment lots: •10232019@1 •12122019@6 •12092019@2 2. Chlorpromazine HCl 50 mg suppository lots: •01132020@2 •01172020@1

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015859129 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015859129. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.