Family Pharmacy Form 483, March 2022
FDA issued this Form 483 to Family Pharmacy in Statesville, North Carolina (FEI 3015859129) at the end of a drug inspection that ended March 11, 2022. It lists 9 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jun 13, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 11, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Jun 13, 2022
- 94 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Poor material flow and wipe-down failures
Your facility was operated in a way that permits poor flow of materials. Specifically, A. During the compounding of Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the (b) (4) and the supplies with sterile (b) (4) prior to introduction into ISO 5 BSC. B. Prior to and after compounding Hydromorphone 1 mg/mL infusion lot #528, the pharmacy technician failed to wipe down the sterile (b) (4) bottle prior to introduction into the ISO 5 BSC.
- 2
Insufficient disinfectant contact time in BSC
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, the sporicidal agent, (b) (4), that your firm uses to clean the surfaces inside of the ISO 5 BSC requires a (b) (4) contact time. Your technician stated that this product is used on an (b) (4) (b) (4) basis and left on the inside surface of the ISO 5 BSC to dry while he performs cleaning of the outside surfaces of the BSC then does a final wipe down inside with sterile (b) (4).
- 3
Media fills do not simulate worst-case operations
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worse case activities and conditions that provide a challenge to aseptic operations. Specifically, the firm's (b) (4) media fill which mimics their high-risk infusion compound, Hydromorphone, was performed with (b) (4) IV bags of (b) (4) each for a total batch size of (b) (4). However, the firm's highest volume as seen on their (b) (4) batch log for this infusion compound is (b) (4). (REPEAT OBSERVATION)
- 4
No HEPA filter in ISO 8 storage area
You did not have a HEPA filter over the area to which sterile product was exposed without any information to support that the components remained sterile throughout the storage period. Specifically, your firm states that the prescription laboratory room is classified as ISO 8 but there is no HEPA filter present. The (b) (4) glassware used in sterile processing are stored in this room.
- 5
Sterilization cycles not verified with endotoxin indicators
The cycle parameters used for (b) (4) of materials used to prepare sterile injectable drug products were not verified using endotoxin indicators. Specifically, you do not use endotoxin indicators to ensure and verify that the temperature and time cycle used to sterilize and (b) (4) glassware is adequate. (REPEAT OBSERVATION)
- 6
Inadequate dynamic smoke studies for airflow
Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area. Specifically, A. According to our interview with the pharmacy technicians, no equipment or supplies were present in the ISO 5 BSC and they did not simulate the worst case scenario compounding activities during the smoke studies. B. Your ISO 7 clean room was certified with both ISO 5 BSC turned on however, subsequent compounding and media fills were performed with (b) (4) hood running which could potentially impact the airflow.
- 7
Rust contamination in hazardous materials cabinet
Non-microbial contamination was observed in your production area. Specifically, we observed what appeared to be rust inside the cabinet storing both hazardous bulk drug substances and hazardous chemicals. The bottom door hinges and the bottom shelf on this cabinet had visible rust shavings.
- 8
Equal pressure allows poor air influx
Your facility design allowed the influx of poor quality air into a higher classified area. Specifically, the pressure between the ISO 8 anteroom and ISO 7 clean room is kept the same possibly leading to lower quality ISO 8 air entering ISO 7 clean room every time the door is opened.
- 9
Non-cleanroom chair in ISO 7 cleanroom
The ISO-classified processing areas had difficult to clean equipment. Specifically, your firm uses a non-cleanroom compliant metal folding chair in the ISO 7 cleanroom while working in the ISO 5 BSC.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3015859129, newest first.
- Form 483, February 2020Inspection ended Feb 12, 2020 · Posted Dec 29, 2020OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.