Skip to content

TAILSTORM HEALTH INC

Phoenix, AZ, United States

FEI 3022483154

Company: MEDIVANT HEALTHCARE · Linked by exact D-U-N-S match (118651212) in FDA registration data

FDA has one inspection on file for TAILSTORM HEALTH INC in Phoenix, AZ (FEI 3022483154). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No system suitability for particle test

      LABORATORY SYSTEM OBSERVATION 1 Established laboratory control mechanisms are not Specifically, Your firm does not have an established system suitability procedure for Obscuration Particle Count Test using your finished drug product release testing. However, your firm has not conducted method suitability testing for particulate matter for sterile intravitreal pre-filled syringes, lot D25110 (BUD: 17/SEP/2026). Your firm utilizes the ((b)(4)) Technique to test injectables, including bevacizumab (Avastin).

    2. Observation 2

      Incomplete laboratory data records

      LABORATORY SYSTEM OBSERVATION 2 Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, Your firm does not have an established procedure for the review of audit trails to ensure the reliability of your analytical testing data. Your Quality unit did not review audit trails. Your batch record checklist does not include confirmatory documentation that audit trails in your analytical instruments and software were reviewed and evaluated as part of batch release. Your firm utilizes the [(6) (-4)] for your finished sterile drug products. Since October 2024, your Quality unit released bevacizumab (Avastin) pre-filled syringes and tirzepatide pre-filled syringes.

    Show observation 3
    1. Observation 3

      Ceiling particle contamination risk

      FACILITIES AND EQUIPMENT SYSTEM OBSERVATION 3 Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. Specifically, On 11/11/2025, during the filling of bevacizumab (Avastin), lot D25120, I observed an unidentified white string on the ceiling of the ISO-classified filling room. The condition is a potential source of particulate contamination within the classified area used for aseptic processing.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Other FEIs recorded as TAILSTORM HEALTH INC

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3022483154 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3022483154. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.