Skip to content

Fuller Industries Inc

1 Fuller Way, Great Bend, Kansas, United States

FEI 1922337DUNS 078704329

FDA has 5 inspections on file for Fuller Industries Inc in Great Bend, Kansas (FEI 1922337), from 2011 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the six FOIA requests for this site have asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations III). No court action or import refusal is filed under this FEI.

Five regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is Fuller Industries, Inc (D-U-N-S 078704329).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2011–2026
3 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
5 of 5
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
6 requests, latest Oct 15, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.

    2. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining appropriate storage conditions and expiration dates.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

    4. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    5. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of quality control unit

      There is no quality control unit.

    2. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    3. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

    4. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    3. Description and Identification of Samples

      Laboratory records are deficient in that they do not include a description and identification of the sample received and lot number.

    4. Failing drug products not rejected

      Drug products failing to meet established specifications and quality control criteria are not rejected.

    5. Items to cover on annual reviews

      Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls and returned or salvaged drug products.

    Show 2 more citations
    1. Approval and review of procedures

      Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

  4. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: Devices2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Nonconforming product, Lack of or inadequate procedures

      Procedures have not been adequately established to control product that does not conform to specified requirements.

    2. DMR - not or inadequately maintained

      A device master record has not been maintained.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Items to cover on annual reviews

      Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.

    2. Quality Control Review

      Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.

    3. GMP Training Frequency

      GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Oct 15, 2026. Each one asked for a Form 483.

  • Inspection ending Jul 23, 2026OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 22, 2026. FDAgent holds no copy that FDA posted.

    1. Oct 15, 2026FDA-FOIA-2026-10046Form 483· 1 of 5 sitesRecords released
    2. Sep 14, 2026FDA-FOIA-2026-8882Form 483· 1 of 5 sitesRecords released
  • Inspection ending Mar 26, 2025OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 11, 2025. FDAgent holds no copy that FDA posted.

    1. May 15, 2026FDA-FOIA-2026-5003Form 483· 1 of 5 sitesRecords released
    2. Jul 10, 2025FDA-FOIA-2025-8497Form 483Records released
    3. May 12, 2025FDA-FOIA-2025-4207Form 483· 1 of 5 sitesClosed
  • Inspection ending Feb 17, 2023OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jan 25, 2024FDA-FOIA-2024-834Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.

Show all 14

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2027
Registrant
Fuller Industries, IncD-U-N-S 078704329

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1922337 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1922337. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.