Skip to content

STAQ Pharma of Ohio LLC

Ohio

FEI 3025336457

FDA has 3 inspections on file for STAQ Pharma of Ohio LLC in Ohio (FEI 3025336457), from 2023 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
3, 2023–2026
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
3 requests, latest May 15, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate visual inspection qualification procedure

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm's visual inspection qualification procedure for sterile injectable drug products compounded and packaged in syringes is inadequate to ensure that visual inspectors are appropriately qualified to detect defects. A. The visual inspection qualification process does not require operators to distinguish between critical and major defects and the acceptance criteria to pass qualification is (b)(4) of defective units identified, regardless of defect severity. For example, the current qualification for [illegible] syringes contains [illegible] defects, of which [illegible] are critical defects and [illegible] are major defects. During qualification, operators are not required to document the specific defect type identified, and qualification proctors determine only whether the rejected units contained an actual defect. Thus, operators may fail to identify up to [illegible] critical defects and still be qualified for visual inspection. B. A single visual inspection challenge [illegible] is maintained for both training and qualification purposes. [illegible] used to qualify visual inspectors for products compounded and packaged in [illegible] The challenge syringes does not include known defect types listed in (b)(4) the batch production records, such as precipitation (cloudiness), particles adhered to the container, and particles adhered to the stopper. In addition, training records do not document whether visual inspection operators are trained on all known defect types prior to qualification. C. Visual inspection data, such as rejected units by defect type, inspector, or shift, are not trended in a manner sufficient to detect systemic defect patterns or identify individual inspector performance issues at the OH location. Since August 2025, approximately (b)(4) batches of compounded drug products have been released.

    2. Observation 2

      Missing in-process light intensity results

      Batch production and control records do not include in-process results for each batch of drug product produced. Specifically, Actual light intensity values measured prior to starting visual inspection are not recorded in the production batch records; instead, the records document only whether the established light intensity acceptance criteria was met using a "Yes/No" check box. For example, for Succinylcholine Chloride 20 mg/mL, 10 mL in 10 mL syringe, Injection Batch 62116169A (batch size (b)(4) syringes, manufactured on (b)(4), BUD 10/30/2026), light intensity was measured during visual inspection, however, the batch record only documented whether the light intensity met the established acceptance criteria.

    Show observation 3
    1. Observation 3

      Inadequate aseptic process validation and gowning

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, Media fills or aseptic process simulations performed do not closely simulate actual production conditions or represent all syringe configurations. In addition, operators were not qualified prior to the introduction of new gowning components to ensure that the gowning was donned appropriately. A. Your firm's media fill program does not include worst-case conditions for all syringe sizes used in sterile compounding operations. No media fill has been performed for the (b)(4) syringe size ([illegible]) since 2024. Approximately, (b)(4) batches in (b)(4) syringes have been compounded and released since October 2025. For example, Sodium Chloride 9 mg/mL, (b)(4) in (b)(4) syringes, Injection Batch 62169152A (batch size (b)(4) syringes, BUD 12/08/2026) was compounded on (b)(4) B. Your firm's media fill program does not adequately simulate actual aseptic production conditions. During media fills, operator fatigue, prolonged aseptic technique, and extended exposure time within the cleanroom environment are not being evaluated or challenged. Operators fill between (b)(4) units during a media fill, however operators may fill (b)(4) syringes during actual compounding. For example, during an operator qualification using 5 mL syringes (Batch 52001187A produced on (b)(4)), only (b)(4) syringes were filled by an operator. In contrast, during operations for the compounding of Dexmedetomidine HCl 4 mcg/mL, 5 mL in 5 mL syringe Batch 62123162A (batch size (b)(4) syringes, manufactured on (b)(4), BUD 12/20/2026), the same operator filled (b)(4) syringes continuously. C. Your firm introduced sterile sleeve covers as a component of the sterile gowning process without ensuring that all operators were qualified to don this new gowning component prior to implementation.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. FDCA 503B(a)(10)(A)

      Drug product labels, fails to include

      The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Media fills, failure

      Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on May 15, 2026. Each one asked for a Form 483.

  • Inspection ending May 16, 2025VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 15, 2026FDA-FOIA-2026-5011Form 483· 1 of 4 sitesWithdrawn
    2. Jul 1, 2025FDA-FOIA-2025-8120Form 483· 1 of 5 sitesRecords released
  • Inspection ending Oct 4, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Nov 6, 2023FDA-FOIA-2023-9796Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3025336457 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3025336457. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.