STAQ Pharma of Ohio LLC Form 483, August 2026

FDA issued this Form 483 to STAQ Pharma of Ohio LLC in Ohio (FEI 3025336457) at the end of an inspection that ended August 19, 2026. It lists 3 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Sep 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 19, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Sep 22, 2026
34 days after the inspection
Facility
FEI 3025336457
Ohio

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate visual inspection qualification procedure

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm's visual inspection qualification procedure for sterile injectable drug products compounded and packaged in syringes is inadequate to ensure that visual inspectors are appropriately qualified to detect defects. A. The visual inspection qualification process does not require operators to distinguish between critical and major defects and the acceptance criteria to pass qualification is (b)(4) of defective units identified, regardless of defect severity. For example, the current qualification for [illegible] syringes contains [illegible] defects, of which [illegible] are critical defects and [illegible] are major defects. During qualification, operators are not required to document the specific defect type identified, and qualification proctors determine only whether the rejected units contained an actual defect. Thus, operators may fail to identify up to [illegible] critical defects and still be qualified for visual inspection. B. A single visual inspection challenge [illegible] is maintained for both training and qualification purposes. [illegible] used to qualify visual inspectors for products compounded and packaged in [illegible] The challenge syringes does not include known defect types listed in (b)(4) the batch production records, such as precipitation (cloudiness), particles adhered to the container, and particles adhered to the stopper. In addition, training records do not document whether visual inspection operators are trained on all known defect types prior to qualification. C. Visual inspection data, such as rejected units by defect type, inspector, or shift, are not trended in a manner sufficient to detect systemic defect patterns or identify individual inspector performance issues at the OH location. Since August 2025, approximately (b)(4) batches of compounded drug products have been released.

  2. 2

    Missing in-process light intensity results

    Batch production and control records do not include in-process results for each batch of drug product produced. Specifically, Actual light intensity values measured prior to starting visual inspection are not recorded in the production batch records; instead, the records document only whether the established light intensity acceptance criteria was met using a "Yes/No" check box. For example, for Succinylcholine Chloride 20 mg/mL, 10 mL in 10 mL syringe, Injection Batch 62116169A (batch size (b)(4) syringes, manufactured on (b)(4), BUD 10/30/2026), light intensity was measured during visual inspection, however, the batch record only documented whether the light intensity met the established acceptance criteria.

  3. 3

    Inadequate aseptic process validation and gowning

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, Media fills or aseptic process simulations performed do not closely simulate actual production conditions or represent all syringe configurations. In addition, operators were not qualified prior to the introduction of new gowning components to ensure that the gowning was donned appropriately. A. Your firm's media fill program does not include worst-case conditions for all syringe sizes used in sterile compounding operations. No media fill has been performed for the (b)(4) syringe size ([illegible]) since 2024. Approximately, (b)(4) batches in (b)(4) syringes have been compounded and released since October 2025. For example, Sodium Chloride 9 mg/mL, (b)(4) in (b)(4) syringes, Injection Batch 62169152A (batch size (b)(4) syringes, BUD 12/08/2026) was compounded on (b)(4) B. Your firm's media fill program does not adequately simulate actual aseptic production conditions. During media fills, operator fatigue, prolonged aseptic technique, and extended exposure time within the cleanroom environment are not being evaluated or challenged. Operators fill between (b)(4) units during a media fill, however operators may fill (b)(4) syringes during actual compounding. For example, during an operator qualification using 5 mL syringes (Batch 52001187A produced on (b)(4)), only (b)(4) syringes were filled by an operator. In contrast, during operations for the compounding of Dexmedetomidine HCl 4 mcg/mL, 5 mL in 5 mL syringe Batch 62123162A (batch size (b)(4) syringes, manufactured on (b)(4), BUD 12/20/2026), the same operator filled (b)(4) syringes continuously. C. Your firm introduced sterile sleeve covers as a component of the sterile gowning process without ensuring that all operators were qualified to don this new gowning component prior to implementation.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3025336457, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.