Rubicon Research Limited
India
FEI 3016480976DUNS 771793568
FDA has one inspection on file for Rubicon Research Limited in India (FEI 3016480976). It ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Rubicon Research Limited (D-U-N-S 771793568).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 1, in 2026
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Sep 1, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unqualified manufacturing and packaging equipment
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use. Specifically, (b)(4) used in the [illegible] 122, which is listed as the equipment [illegible] for manufacturing for (b)(4) mg strengths of (b)(4) Tablets, is not qualified. Only an installation qualification has been completed. B) (b)(4) Machine (b)(4) with ID #(b)(4) 009 was moved from Room #(b)(4) under Change Control CC/1501/26-007 requiring requalification of the (b)(4) to (b)(4) equipment prior to its use in commercial manufacturing. Performance Qualification, as required by the change control, has not been completed. C) Equipment qualification of equipment used in labeling and packaging operations of (b)(4) Tablets has not been completed. These include the following pieces of equipment: (b)(4)
- Observation 2
Missing cleaning procedures and documentation
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A) There is no procedure currently in effect for the cleaning of the (b)(4) used for manufacturing (b)(4) Tablets (b)(4) mg strengths. 122 (b)(4) B) There is no cleaning record which documents the step-by-step cleaning activities required during the cleaning of the product contact (b)(4) 006, used for (b)(4) Tablets. Procedure: SOP/EQP/1501/000707, Usage and Cleaning of (b)(4) Effective Date: 01-Dec-2025, Version: 1, lists specific cleaning durations for each stage of cleaning. There is no documentation to demonstrate the minimum cleaning duration for each stage was met.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Sep 1, 2026. Each one asked for a Form 483.
Inspection ending Jul 3, 2026Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Sep 1, 2026FDA-FOIA-2026-8504Form 483Records released
- Jul 13, 2026FDA-FOIA-2026-6669Form 483Records released
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Aug 20, 2026. FDAgent holds no copy that FDA posted.
- Date not givenFDA-FOIA-2026-7521Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Rubicon Research LimitedD-U-N-S 771793568
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Rubicon Research Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Rubicon Research LimitedFEI 3008252295Thane, India
Last inspected 2024-11-07NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3016480976 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3016480976. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.