FDA issued this Form 483 to Glenmark Pharmaceuticals Limited in Colvale, India (FEI 3004672766) at the end of a drug inspection that ended June 30, 2026. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 16, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 30, 2026
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 16, 2026
139 days after the inspection
Facility
FEI 3004672766
Colvale, India

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate equipment cleaning and disinfectant validation

    Equipment and utensils are not cleaned or sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A. Inadequate Cleaning Procedures-Insufficient Time Allocation Your firm's written cleaning procedure, SOP CM/PD002 "Cleaning and Sanitization of Production Areas, Other than Production Areas, Wash Areas and Drain Points", establishes requirements for Type A cleaning and Type B cleaning of (b)(4) manufacturing rooms. Type A cleaning is performed during continued production of the same product, while Type B cleaning is performed during product changeover to prevent cross-contamination between different drug products. Review of cleaning records for (b)(4) rooms revealed documented cleaning times that are physically insufficient to complete all required procedural steps. 1. Type A Cleaning - Examples of Inadequate Times Type A cleaning requires sequential steps for (b)(4) operations. The following examples demonstrate that documented cleaning times do not allow completion of all required steps: March 17, 2026: (b)(4) Room (b)(4) (1 minute) - documented as completing (b)(4). August 18, 2025: (b)(4) Room (b)(4) (5 minutes) - documented as completing (b)(4). March 18, 2026: (b)(4) Room (b)(4) (5 minutes) - documented as completing (b)(4). 2. Type B Cleaning - Examples of Inadequate Times Type B cleaning is performed during product changeover and requires more extensive cleaning than Type A, including wet cleaning (using (b)(4)) and visual inspection of cleaned areas to confirm (b)(4) effectiveness. Review of Type B cleaning records revealed that documented times are insufficient to complete all required steps: April 22, 2026: (b)(4) Facility (Unit (b)(4)), Room (b)(4) (14 minutes) - documented as completing wet cleaning of (b)(4) operations, and visual inspection of floor corners, edges, and under-equipment areas. January 16, 2025: (b)(4) Facility (Unit (b)(4)) Room (b)(4) (8 minutes) - documented as completing wet cleaning of (b)(4) operations, and required visual inspection. February 13, 2025: (b)(4) Facility (Unit (b)(4)) Room (b)(4) (5 minutes) - documented as completing wet cleaning of (b)(4) and required visual inspection. February 21, 2025: (b)(4) (Unit (b)(4)) Room (b)(4) (11 minutes) - documented as completing wet cleaning of (b)(4) operations, and required visual inspection. Your firm has not established a minimum or validated cleaning time for Type A and Type B cubicle cleaning. Without scientifically justified time requirements, there is no basis to determine whether documented cleaning times are adequate to complete all required procedural steps. B. Lack of Validated Contact Time for Disinfectants 1. Protocol MSP/QC/2023/005/00/CMPD002 (effective 13/02/2023) and Summary Report MSR/QC/2023/005/00/CMPD002 (dated 01/06/2024) were conducted to demonstrate the effectiveness of the disinfectants used in the sanitization procedure. However, the study design cannot demonstrate disinfectant efficacy because it lacks the following critical elements: Positive controls, Pre-cleaning microbial counts, Deliberate microbial challenge, Untreated control surfaces, Inadequate Acceptance Criteria. 2. The study's acceptance criteria of "Total aerobic Microbial count: NMT (b)(4) cfu/plate" fails to demonstrate disinfectant efficacy for two reasons: The acceptance criteria is identical to routine environmental monitoring limits for Grade D areas and therefore does not demonstrate disinfectant efficacy. The acceptance criteria measures surface cleanliness, meaning there is no scientific basis to distinguish between effective disinfection and low baseline contamination. There is no scientific justification for the absence of a log reduction calculation requirement. Your firm's own 2016 validation (Protocol VP/MM/QC/206) established acceptance criteria of (b)(4)% reduction for vegetative organisms and ≥(b)(4)% reduction for spores, yet these st

    Shortened here; the PDF has the full text.

  2. 2

    Inadequate controls over computerized manufacturing systems

    Appropriate controls were not exercised over computer or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. (b)(4) machines - the (b)(4) are all documented as having no electronic data storage or audit trail capability. These machines are used to manufacture multiple tablet products for distribution in the United States, including (b)(4). As a result: 1. The (b)(4) machines lack electronic data storage and audit trail functionality. While printed reports are generated and subsequently scanned for archival, the original electronic data on the machines themselves cannot be retrieved, trended, or audited. This prevents verification of: a. Authorization status of changes at the time they were made b. Detection of unauthorized modifications to data other than process parameters c. Systematic trending of parameter drift or equipment performance degradation. 2. There is no documented procedure establishing acceptable limits on the number or magnitude of parameter adjustments an operator may make during a single batch run within the validated range. An operator may make unlimited corrections to (b)(4) or other parameters without documented justification, and there is no mechanism to detect whether such frequent adjustments indicate process instability or equipment drift. 3. While non-critical alarms are logged in batch records and a Work Request Memo (WRM) system exists to document equipment issues requiring engineering intervention, there is no documented procedure establishing threshold criteria (frequency or severity triggers) that define when non-critical alarms require investigation and escalation beyond routine maintenance. B. (b)(4) machines - the (b)(4) are used to manufacture multiple tablet products for distribution in the United States, including (b)(4). Although these machines are equipped with electronic data storage and backup capability, appropriate controls are not exercised to assure that changes to process parameters are instituted only by authorized personnel, and procedures do not establish monitoring and investigation requirements for equipment "Non-Critical" alarms and parameter deviations. Specifically: 1. While the electronic audit trail captures date, time, personnel identity, old value, and new value of parameter changes, your procedures do not establish requirements to review the audit trail for: the sequence and frequency of parameter changes during a batch, whether changes were made for documented reasons, whether the pattern of changes indicates process instability or equipment drift, or whether changes were appropriate given the product and process stage. The audit trail is reviewed only for compliance with specification limits, not for assessment of the adequacy or appropriateness of the changes themselves. 2. Your procedures do not establish requirements to monitor the frequency or pattern of non-critical alarms, define investigation criteria or trigger points for repeated non-critical alarms that may indicate emerging equipment problems, or require documentation of non-critical alarm occurrences for trend analysis. 3. While your SOPs establish acceptance limits for process parameters and define alarm thresholds, the procedures do not establish predefined investigation criteria for parameter deviations that do not generate alarms. The SOPs do not establish predefined trigger points for investigation of parameter drift within acceptable limits or trend monitoring of parameters that remain within specification but show directional drift.

  3. 3

    High-risk components not tested per container

    Each component is not tested for conformity with all written specifications for purity, strength, and quality. Specifically, Your firm failed to perform individual container testing, including identity testing with limits for (b)(4) (NMT (b)(4)%), on each individual container of each shipment of each lot of high-risk drug components prior to their use in manufacturing of drug products distributed to the United States market. Your procedure for sample testing, Sampling, Testing and Release of Raw Materials, SOP 19/QC006, allows analysis of (b)(4) samples. The high-risk raw materials tested using (b)(4) samples include: Raw Material Most recent Glenmark material batch # (b)(4). These raw materials have been used to manufacture commercial product intended for the US market including (b)(4).

  4. 4

    Inadequate contamination and cross-contamination controls

    Control systems for the firm's operations are not adequate to prevent contamination or mix-ups. Specifically, A. Differential pressure in the manufacturing areas of the (b)(4) facility (Unit (b)(4)) is not adequately monitored and recorded, and no alarm system is in place to detect differential pressure excursions. A review of the Batch Production Record (BPR) for Batch (b)(4) ((b)(4) USP (b)(4) mcg), confirmed that the differential pressure is recorded only during active batch production, approximately (b)(4), with no continuous monitoring or alarm system to ensure pressure differentials are maintained. Your firm manufactures (b)(4) drug products approved for the U.S. market in Unit (b)(4). Approximately (b)(4) distinct batches - including (b)(4) - were shipped to the U.S. between January 2023 and June 2026. Your firm also manufactures (b)(4) tablets in the same facility as (b)(4) products and these (b)(4) tablets are (b)(4) tablets for at least (b)(4) commercial products marketed in the U.S. All these (b)(4) batches remain within their approved expiry dates as of the date of this inspection (June 30, 2026). B. Although a risk assessment with containment study was done in 2023 and 2025, your firm has not conducted a comprehensive risk assessment prior to this inspection on June 22, 2026, to evaluate the potential for cross-contamination between the (b)(4) manufacturing facility (Unit (b)(4)) and the (b)(4) facility (Unit (b)(4)). The Units are located approximately (b)(4) away from each other. For example, your firm has not performed a scientific evaluation of potential cross-contamination between the (b)(4) two facilities, including an assessment of the location and (b)(4) points of the (b)(4) systems in relation to the (b)(4) facility; the adequacy and a program for periodic environmental monitoring between the facilities; the (b)(4) vents of the (b)(4) facility's (b)(4).

  5. 5

    Annual product reviews omitted complaint records

    Written procedures for annual product reviews are not followed, and the reviews are deficient in that they do not address a review of complaint records for each drug product. Specifically, Your firm failed to include a review of all complaints in the Annual Product Quality Review (APQR). Your procedure, "SOP CM/QA005, Revision 17: Periodic Review of Product Quality of Drug Products," requires the compilation of market complaints for the APQR. However, complaints were not included in the APQR for the following products: A. Product: (b)(4) Tablets The APQR for the review period of March 25, 2024, to March 24, 2025 (APQR/25/US/007) reported zero (0) market complaints. However, a review of your firm's complaint records identified eleven (11) complaints associated with this product within the review period that were not included in the APQR including complaints for lack of efficacy and missing blisters. B. Product: (b)(4) Tablets The APQR for the review period of January 19, 2024, to January 18, 2025 (APQR/25/US/001) reported one (1) market complaint. However, a review of your firm's complaint records identified a total of two (2) complaints associated with this product within the review period. Complaint number MC/I102/2024/0065 for missing blister was not included in the APQR.

  6. 6

    Incomplete lab data due to Empower privileges

    Laboratory records do not include complete data derived from all tests, examinations, and assays necessary to assure compliance with established specifications and standards. Specifically, Your analysts have been granted user privileges within the Empower software that allow them to view numerical results in the review window - including area counts of peaks - while changing processing methods, without requiring the chromatograms to be saved. This configuration allows for the potential previewing of data. While these series of controls were in place, your firm has tested over (b)(4) batches of finished drug products for assay and/or impurities by HPLC since January 2023. These products include, but are not limited to, (b)(4). Furthermore, prior to this inspection, your firm did not conduct a comprehensive risk assessment to identify and control the data integrity risks introduced by these user privilege configurations.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3004672766, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.