FDA has one inspection on file for Mixlab WI LLC in Milwaukee, Wisconsin (FEI 3005946041). It ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 24, 2025 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below. One FOIA request asked FDA for the 483 from a later inspection, ending Jul 24, 2025, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 1 request, latest Oct 14, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesPosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Beta-lactam containment and cleaning deficiencies
You produced beta-lactam drugs without providing adequate containment, cleaning of work surfaces, and cleaning of utensils to prevent cross-contamination. Specifically, Beta-lactam drugs are produced in non-designated areas sharing the same work surfaces and equipment that are also used to produce non-beta-lactam drugs, of which are not cleaned/sanitized with bleach and isopropyl alcohol (70%) to provide adequate inactivation of the drug. For example, the following prescriptions for beta-lactam drugs were produced on work surfaces and equipment that were cleaned/sanitized with (b) (4) (b) (4) and later used to produce non-beta-lactam drugs, which may be at risk of cross-contamination: -Rx (b) (6) Amoxicillin capsules 150mg on 4/25/2018 -Rx (b) (6) Cyclophosphamide capsules 13mg on 7/19/2018 -Rx (b) (6) Cyclosporine liquid suspension 50mg/mL on 7/13/2018 Additionally, there are no controls or procedures in place for production of beta-lactam drugs to be contained within a separate air handling unit. The use of (b) (4) HEPA-filtered containment hoods for production of beta-lactam drugs is optional, as reported by the pharmacist-in-charge.
- Observation 2
No written cleaning procedures or agents
Cleaning methods are not established in a written procedure nor are appropriate cleaning agents specified. Specifically, a.) Drug product production equipment such as capsule filling trays and spatulas/mortars/pestles/spinners are not rinsed with purified water and/or sanitized with appropriate sanitizing agents after cleaning with hot water and dish soap. b.) There are no defined/labeled areas for storage of "clean" and "unclean" drug production equipment/utensils and cloth cleaning towels. These items were observed on counter tops in the cleaning area by the 2-compartment sink without identification of "clean" or "unclean" status or any other unique identifier. c.) There are no cleaning procedures defining what cleaning/sanitizing agents are acceptable and when/how to use them. For example, (b) (4) is used to clean/sanitize benchtops and analytical balances after use for each drug product produced (witnessed after production of budesonide capsules 1mg: Rx (b) (6) and metronidazole capsules 62.5mg: Rx (b) (6)); however, (b) (4) may also be used to clean/sanitize benchtops as well, as reported by the pharmacist-in-charge. Additionally, there are no specified cleaning/sanitizing agents (bleach and IPA 70%) or instructions for cleaning work surfaces and equipment after production of beta-lactam containing drug products.
Show observations 3 to 9
- Observation 3
Balances not calibrated or identified
Analytical balances, used for weighing drug materials/components, are not uniquely identified nor appropriately calibrated on a periodic basis, nor periodically weight checked with an appropriate certified weight set. Examples include, but not limited to: - (b) (4) (Model (b) (4) - (b) (4) (Model (b) (4)) - (b) (4) ((b) (4)) - (b) (4) (S/N (b) (4)) No calibration or maintenance records for the aforementioned analytical balances, used for drug product production, were provided. During production of a prescription fill for budesonide capsules 1mg on 7/27/2018 (Rx (b) (6)) it was observed that a non-calibrated analytical balance was used.
- Observation 4
Deficient prescription production records
Prescription production records are deficient in that they do not include the following: -name of manufacturers, lot numbers, and expiry dates of all materials/components used. -identification of any automated, mechanical, or electronic equipment that is used during drug processing; e.g. analytical balances. -proof or second-check verification of weights/volumes recorded for each component used. For example, the prescription production records for a prescription fill of a tramadol suspension 20mg/mL (Rx (b) (6)) on 7/09/2018 lack these aforementioned items.
- Observation 5
No technician training program records
Your pharmacy does not have an established training program for technicians nor do you maintain any training record documentation for on-the-job training that was provided to them. Dosage forms prepared by technicians range from aqueous solutions, oils/suspensions, capsules, chew treats, eye drops, to transdermals.
- Observation 6
Protective apparel not worn consistently
Appropriate protective apparel is not always worn by technicians to protect drug products from contamination during production. Specifically, several technicians were observed producing drug formulations without hair nets and/or designated gowning/apparel during the inspection. For example, during production of metronidazole capsules 62.5mg (Rx (b) (6)) on 7/31/2018 a technician with long hair was observed without a hairnet.
- Observation 7
No quality event handling procedures
Your pharmacy does not have established written procedures for handling and maintaining records for quality-related events, such as for complaints, ADE/MedWatch reporting, recalls, deviations, and investigations. For example, no records for a complaint investigation involving a prescription refill of phenobarbital capsules 6mg on 10/19/2017 (Rx (b) (6)) for super potency were provided.
- Observation 8
No receipt and storage controls
Your pharmacy does not have established written procedures or adequate controls in place for receipt and storage of materials/components used to produce drug products. Specifically, a.) Materials/components used to produce drugs are not all classified and/or identified upon receipt as either being non-hazardous, hazardous/highly potent, containing beta-lactams, or controlled substances. b.) Storage of hazardous/highly potent materials, controlled substances, and beta-lactam containing materials are not always segregated or accounted for appropriately. c.) Inventory records for materials/components used to produce drugs are not maintained for those currently on-hand. d.) Pertinent information on incoming materials/components used to produce drugs, such as the name of manufacturers and whether they are an approved supplier, lot numbers, and if an accompanying CoA for bulk chemical materials/components is received, are not recorded and/or checked for as per a written procedure.
- Observation 9
Beyond Use Dates not justified
Criteria for Beyond Use Dates (BUDs) assigned to drug formulations produced by your pharmacy are not formally and appropriately established in a written procedure nor supported with cited literature references and/or stability studies. For example, no cited literature or other evidence was provided in support of a BUD of 60 days for a phenobarbital suspension 6mg/mL (Rx (b) (6)).
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Oct 14, 2025. It asked for a Form 483.
Inspection ending Jul 24, 2025
1 request. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.
- Oct 14, 2025FDA-FOIA-2025-11904Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005946041 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005946041. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.