The Pet Apothecary LLC Form 483, August 2018
FDA issued this Form 483 to The Pet Apothecary LLC in Milwaukee, Wisconsin (FEI 3005946041) at the end of a veterinary inspection that ended August 7, 2018. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 12, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 7, 2018
- Veterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 12, 2019
- 339 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Beta-lactam containment and cleaning deficiencies
You produced beta-lactam drugs without providing adequate containment, cleaning of work surfaces, and cleaning of utensils to prevent cross-contamination. Specifically, Beta-lactam drugs are produced in non-designated areas sharing the same work surfaces and equipment that are also used to produce non-beta-lactam drugs, of which are not cleaned/sanitized with bleach and isopropyl alcohol (70%) to provide adequate inactivation of the drug. For example, the following prescriptions for beta-lactam drugs were produced on work surfaces and equipment that were cleaned/sanitized with (b) (4) (b) (4) and later used to produce non-beta-lactam drugs, which may be at risk of cross-contamination: -Rx (b) (6) Amoxicillin capsules 150mg on 4/25/2018 -Rx (b) (6) Cyclophosphamide capsules 13mg on 7/19/2018 -Rx (b) (6) Cyclosporine liquid suspension 50mg/mL on 7/13/2018 Additionally, there are no controls or procedures in place for production of beta-lactam drugs to be contained within a separate air handling unit. The use of (b) (4) HEPA-filtered containment hoods for production of beta-lactam drugs is optional, as reported by the pharmacist-in-charge.
- 2
No written cleaning procedures or agents
Cleaning methods are not established in a written procedure nor are appropriate cleaning agents specified. Specifically, a.) Drug product production equipment such as capsule filling trays and spatulas/mortars/pestles/spinners are not rinsed with purified water and/or sanitized with appropriate sanitizing agents after cleaning with hot water and dish soap. b.) There are no defined/labeled areas for storage of "clean" and "unclean" drug production equipment/utensils and cloth cleaning towels. These items were observed on counter tops in the cleaning area by the 2-compartment sink without identification of "clean" or "unclean" status or any other unique identifier. c.) There are no cleaning procedures defining what cleaning/sanitizing agents are acceptable and when/how to use them. For example, (b) (4) is used to clean/sanitize benchtops and analytical balances after use for each drug product produced (witnessed after production of budesonide capsules 1mg: Rx (b) (6) and metronidazole capsules 62.5mg: Rx (b) (6)); however, (b) (4) may also be used to clean/sanitize benchtops as well, as reported by the pharmacist-in-charge. Additionally, there are no specified cleaning/sanitizing agents (bleach and IPA 70%) or instructions for cleaning work surfaces and equipment after production of beta-lactam containing drug products.
- 3
Balances not calibrated or identified
Analytical balances, used for weighing drug materials/components, are not uniquely identified nor appropriately calibrated on a periodic basis, nor periodically weight checked with an appropriate certified weight set. Examples include, but not limited to: - (b) (4) (Model (b) (4) - (b) (4) (Model (b) (4)) - (b) (4) ((b) (4)) - (b) (4) (S/N (b) (4)) No calibration or maintenance records for the aforementioned analytical balances, used for drug product production, were provided. During production of a prescription fill for budesonide capsules 1mg on 7/27/2018 (Rx (b) (6)) it was observed that a non-calibrated analytical balance was used.
- 4
Deficient prescription production records
Prescription production records are deficient in that they do not include the following: -name of manufacturers, lot numbers, and expiry dates of all materials/components used. -identification of any automated, mechanical, or electronic equipment that is used during drug processing; e.g. analytical balances. -proof or second-check verification of weights/volumes recorded for each component used. For example, the prescription production records for a prescription fill of a tramadol suspension 20mg/mL (Rx (b) (6)) on 7/09/2018 lack these aforementioned items.
- 5
No technician training program records
Your pharmacy does not have an established training program for technicians nor do you maintain any training record documentation for on-the-job training that was provided to them. Dosage forms prepared by technicians range from aqueous solutions, oils/suspensions, capsules, chew treats, eye drops, to transdermals.
- 6
Protective apparel not worn consistently
Appropriate protective apparel is not always worn by technicians to protect drug products from contamination during production. Specifically, several technicians were observed producing drug formulations without hair nets and/or designated gowning/apparel during the inspection. For example, during production of metronidazole capsules 62.5mg (Rx (b) (6)) on 7/31/2018 a technician with long hair was observed without a hairnet.
- 7
No quality event handling procedures
Your pharmacy does not have established written procedures for handling and maintaining records for quality-related events, such as for complaints, ADE/MedWatch reporting, recalls, deviations, and investigations. For example, no records for a complaint investigation involving a prescription refill of phenobarbital capsules 6mg on 10/19/2017 (Rx (b) (6)) for super potency were provided.
- 8
No receipt and storage controls
Your pharmacy does not have established written procedures or adequate controls in place for receipt and storage of materials/components used to produce drug products. Specifically, a.) Materials/components used to produce drugs are not all classified and/or identified upon receipt as either being non-hazardous, hazardous/highly potent, containing beta-lactams, or controlled substances. b.) Storage of hazardous/highly potent materials, controlled substances, and beta-lactam containing materials are not always segregated or accounted for appropriately. c.) Inventory records for materials/components used to produce drugs are not maintained for those currently on-hand. d.) Pertinent information on incoming materials/components used to produce drugs, such as the name of manufacturers and whether they are an approved supplier, lot numbers, and if an accompanying CoA for bulk chemical materials/components is received, are not recorded and/or checked for as per a written procedure.
- 9
Beyond Use Dates not justified
Criteria for Beyond Use Dates (BUDs) assigned to drug formulations produced by your pharmacy are not formally and appropriately established in a written procedure nor supported with cited literature references and/or stability studies. For example, no cited literature or other evidence was provided in support of a BUD of 60 days for a phenobarbital suspension 6mg/mL (Rx (b) (6)).
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3005946041, newest first.
- Form 483, July 2025FDA record date Jul 24, 2025 · Posted Jul 1, 2026
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.