Skip to content

Alkem Laboratories Limited Form 483, March 2017

FDA issued this Form 483 to Alkem Laboratories Limited in Tehsil Nalagarh, Baddi, India (FEI 3006370533) at the end of a drug inspection that ended March 10, 2017. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Mar 28, 2017. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 10, 2017
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Mar 28, 2017
18 days after the inspection
Facility
FEI 3006370533
Tehsil Nalagarh, Baddi, India

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Stability testing not performed per schedule

    The written testing stability program is not followed. The required stability testing on numerous drug products (over approximately 1,000 individual samples) was not completed within the time frames established in procedure Stability Management QC/063/07, current at the time the samples were due for testing. Deviation B/DQ/15/014 was opened November 13, 2015 and CAPA B/CAPA/15/122 was opened December 15, 2015 to address missing the analysis time frames. Over two hundred and fifty samples were identified beyond their required analysis time frames. A target date of December 31, 2015 was set to complete the analysis on these samples. There is no documentation to show this target date was met. Deviation B/DQ/15/015 was opened December 18, 2015 to address the increase of stability samples outside their required analysis time frames. Over five hundred samples were identified beyond their required analysis time frame and a target date of February 25, 2016 was set to complete these samples. There is no documentation to show this target date was met.

  2. 2

    Incomplete production and control instructions

    Master production and control records lack complete manufacturing and control instructions and special notations. A. Procedure QC/082, Operation, Cleaning and Calibration of (b) (4) (Revision 07), does not contain instructions for the use of (b) (4) to complete the validated load pattern in the (b) (4) (G/QC/099). Firm management stated (b) (4) is used to fulfill media loads to be sterilized; however, this is not fully documented. B. Performance Qualification PQ_WIHC_01 Revision 1 covering (b) (4) Humidity Chambers G/QC/465 and G/QC/370 does not contain detailed information regarding the load. Firm management confirmed all of the chambers were qualified the same way. For example, Chamber G/QC/465 was qualified for the 40±2°C/75 RH ±5% setting and is intended for stability management of US product, including but not limited to, (b) (4) Tabs (b) (4) mg (b) (4) (b) (4) ng Tablets (b) (4) and (b) (4) Tablets (b) (4) ng (b) (4) Chamber G/QC/370 was qualified for the 25±2°C/60 RH ±5% setting and is intended for stability management of US product, including but not limited to, (b) (4) Tablets (b) (4) mg (b) (4) (b) (4) Tablets (b) (4) ng (b) (4), and (b) (4) Capsules USP (b) (4) ng (b) (4) (b) (4)

  3. 3

    No procedures for manual capsule inspection

    There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, the 100% visual inspection of filled capsules conducted in Block (b) (4) prior to packaging, is performed manually on a (b) (4) There is no written procedure describing this process, training specific to this manual operation, lighting requirements, capsule rotation, and control of the volume of capsules on the (b) (4) Manual inspection was observed on March 2, 2017 for (b) (4) Capsules USP, (b) (4) Lot (b) (4)

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3006370533, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.