Skip to content

Alkem Laboratories Limited

Khasra No 1544, 1553, 1558, 1559 Village Thana, Tehsil Nalagarh, Baddi, India

FEI 3006370533DUNS 677605851

Company: Alkem Laboratories Limited · Linked by exact D-U-N-S match (650066939) in FDA registration data

FDA has 9 inspections on file for Alkem Laboratories Limited in Tehsil Nalagarh, Baddi, India (FEI 3006370533), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One FOIA request has asked FDA for this inspection's 483.

14 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, analysis and repacking, through Dec 31, 2027. Its registrant, Alkem Laboratories Limited (D-U-N-S 650066939), has registered 3 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
9, 2009–2024
0 OAI · 7 VAI · 2 NAI
Inspections with 483 observations shown
3 of 9
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
1 request, latest Aug 1, 2024
Warning letters
None on file
Import refusals
14 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to investigate instrument malfunction

      QUALITY SYSTEM OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. During the preventive maintenance of Perkin Elmer UV Spectrophotometer ID #G/QC/225 connected to software and computer (UV WinLab ES 6.5.0.103 and computer ID #ABA/EQ/QC/COM/01187) on 06/28/2023, you encountered a failure for the instrument where the power supply and main board of instrument was not working. According to your service provider on 07/28/2023, the equipment could not be repaired. On 12/08/2023, you proposed to retire Perkin Elmer UV Spectrophotometer ID #G/QC/225 as change control PR ID #128741. Yet, you have not performed an investigation and any impact assessment on the previous generated test results from the UV Spectrophotometer before (b) (4) recording the instrument malfunction. You have tested batches of multiple products on that instrument which have been released into US market. For example, Date of Analysis Product Name Batch No. Shipped to US Release Date (b) (4) (b) (4) (b) (4) 3/30/2023 Tablets Yes 4/6/2023 Tablets Yes (b) (4) (b) 4/13/2023 Tablets (4) mg Yes

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

    3. Approve or reject components, products

      The quality control unit lacks the responsibility and authority to approve and reject all drug products.

    4. Acceptance of in-process materials

      Determinations of conformance to appropriate written specifications for acceptance are deficient for in-process materials.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Stability testing not performed per schedule

      The written testing stability program is not followed. The required stability testing on numerous drug products (over approximately 1,000 individual samples) was not completed within the time frames established in procedure Stability Management QC/063/07, current at the time the samples were due for testing. Deviation B/DQ/15/014 was opened November 13, 2015 and CAPA B/CAPA/15/122 was opened December 15, 2015 to address missing the analysis time frames. Over two hundred and fifty samples were identified beyond their required analysis time frames. A target date of December 31, 2015 was set to complete the analysis on these samples. There is no documentation to show this target date was met. Deviation B/DQ/15/015 was opened December 18, 2015 to address the increase of stability samples outside their required analysis time frames. Over five hundred samples were identified beyond their required analysis time frame and a target date of February 25, 2016 was set to complete these samples. There is no documentation to show this target date was met.

    2. Observation 2

      Incomplete production and control instructions

      Master production and control records lack complete manufacturing and control instructions and special notations. A. Procedure QC/082, Operation, Cleaning and Calibration of (b) (4) (Revision 07), does not contain instructions for the use of (b) (4) to complete the validated load pattern in the (b) (4) (G/QC/099). Firm management stated (b) (4) is used to fulfill media loads to be sterilized; however, this is not fully documented. B. Performance Qualification PQ_WIHC_01 Revision 1 covering (b) (4) Humidity Chambers G/QC/465 and G/QC/370 does not contain detailed information regarding the load. Firm management confirmed all of the chambers were qualified the same way. For example, Chamber G/QC/465 was qualified for the 40±2°C/75 RH ±5% setting and is intended for stability management of US product, including but not limited to, (b) (4) Tabs (b) (4) mg (b) (4) (b) (4) ng Tablets (b) (4) and (b) (4) Tablets (b) (4) ng (b) (4) Chamber G/QC/370 was qualified for the 25±2°C/60 RH ±5% setting and is intended for stability management of US product, including but not limited to, (b) (4) Tablets (b) (4) mg (b) (4) (b) (4) Tablets (b) (4) ng (b) (4), and (b) (4) Capsules USP (b) (4) ng (b) (4) (b) (4)

    Show observation 3
    1. Observation 3

      No procedures for manual capsule inspection

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, the 100% visual inspection of filled capsules conducted in Block (b) (4) prior to packaging, is performed manually on a (b) (4) There is no written procedure describing this process, training specific to this manual operation, lighting requirements, capsule rotation, and control of the volume of capsules on the (b) (4) Manual inspection was observed on March 2, 2017 for (b) (4) Capsules USP, (b) (4) Lot (b) (4)

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 1, 2024. It asked for a Form 483.

  • Inspection ending Mar 27, 2024VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 1, 2024FDA-FOIA-2024-6761Form 483· 1 of 2 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 9 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006370533, one row per refused product line.

14 refusals from 2017-03-16 to 2026-09-14 · charged UNAPPROVED on 14 · no FDA sample analysis

FDA firm profile
  • 2026-09-14

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCA03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports1FX-3134629-0/10002/3

  • 2026-09-02

    MISCELLANEOUS PATENT MEDICINES, ETC.66VDB99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports1FX-8133799-0/10002/1

  • 2026-08-25

    CLINDAMYCIN PHOSPHATE (LINCOMYCINS)56JCY31

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports1FX-0455126-4/30002/2

  • 2025-02-21

    DOMPERIDONE61TDA31

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-5624433-0/11/4

  • 2024-11-04

    MISCELLANEOUS PATENT MEDICINES, ETC.66VCY99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-5822275-1/21/1

Show 9 more
  • 2022-03-28

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCA03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7626844-0/41/1

  • 2022-03-25

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BDA03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-7725460-5/21/1

  • 2021-12-22

    ANTIBIOTIC N.E.C.56YCA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-6370359-9/31/4

  • 2021-04-12

    OMEPRAZOLE (ANTI-PERISTALTIC, ANTI-DIARRHEAL)62KCA10

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-1745728-4/11/1

  • 2020-09-16

    DOMPERIDONE61TDY31

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-1879171-7/11/10

  • 2019-10-01

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCH03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-6349241-4/21/1

  • 2017-05-31

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCE03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsUPS-3549397-3/11/2

  • 2017-05-31

    AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCA03

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsUPS-3549397-3/11/1

  • 2017-03-16

    DOMPERIDONE61TDY31

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Cincinnati District OfficeUPS-2738902-3/11/3

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis, repacking
Registration runs through
Dec 31, 2027
Registrant
Alkem Laboratories LimitedD-U-N-S 650066939

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Alkem Laboratories Limited (D-U-N-S 650066939) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3006370533 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3006370533. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.