Alkem Laboratories Limited
Dabhel, Mahatma Gandhi Udyog Nagar, India
FEI 3006370524DUNS 915628612
Company: Alkem Laboratories Limited · Linked by exact D-U-N-S match (650066939) in FDA registration data
FDA has 7 inspections on file for Alkem Laboratories Limited in India (FEI 3006370524), from 2011 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Two FOIA requests have asked FDA for this inspection's 483.
6 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, analysis and repacking, through Dec 31, 2027. Its registrant, Alkem Laboratories Limited (D-U-N-S 650066939), has registered 3 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 7, 2011–2026
- 0 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 7
- Requested under FOIA
- 2 requests, latest Jul 2, 2026
- Warning letters
- None on file
- Import refusals
- 6 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetDrug Product ManufacturerPosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate OOS/OOT investigations and recalls
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your investigations relating to Out of Specification (OOS) and Out of Trend (OOT) investigations are not thoroughly investigated and the CAPA taken is inadequate to determine the risk to the drug products sold into the US market. For example, A. Your OOS and OOT investigations for ge USP gy ml, and ga) mle AQ are not thoroughly investigated. For example, OOS Investigation Number: 157370, Date of Initiation ge) , Product: gq) USP gy ml ga Batch Number: gq , Mfg. date: , Expiry date: ga Stability Timepoint: 6-month long term stability condition (25°C/60%RH), Shelf life of product: gu Issue: Related Substances by HPLC test found OOS test result for individual unidentified impurity (due to an unknown peak at RRT about ga Result: ga %, Limit: NM Tg %, Investigation conclusion: Valid/Confirmed OOS. Your Quality Unit reported Field Alert (FAR/A/24/010) on ge to the agency but this annual stability batch gg was not recalled from the US market upon confirming OOS at 6-month stability timepoint. This batch failed again at 12-month stability time for the same individual unidentified impurity at RRT about wa (Result: gay %) on ke. Your firm initiated OOS investigation number 178824 for the 12-month failure and confirmed the test results as valid. Subsequently, your Quality Unit analyzed retention samples of ®@ USP gy) ml, and gg) mig through protocol (A/PCR/0506-000) and found OOT test results for out of; batches. The details are as follows: Table 1 Sr. No. | Batch number | Expiry date | Age of the batch when tested in Month (M) | Highest Individual Unidentified Impurity (Limit: [illegible] %) On gy , your firm recalled the above batches including the OOS batch g, gy with a delay of about gq from the date gq of becoming aware of the failing test results for ®@ USP ml. The delayed recall led to multiple batches either expiring in ®@ or nearing to its expiry gw (refer to Table 1). Furthermore, on ga your firm had conducted OOS investigation number: 6715 for individual unidentified impurity of annual stability batch failure at 3-month long term stability condition (25°C/60%RH), unidentified impurity (Result: gy@ %) for batch number ge. Product: ga USP mya ml, ma The OOS investigation concluded as valid OOS. However, the failing batch remained in distribution in the US market. This batch failed again at 9-month long term stability timepoint for individual unidentified impurity (Resultmye %) on me (OOS Investigation: 18622). However, your firm did not recall the batch until a from the US market. This was with a delay of about ga from the date of becoming aware of the failing test results for ge ®@ USP gy) ml. Moreover, your firm obtained valid OOS (OOS Investigation: 26190) test result at 3-month long term stability (25°C/60%RH) condition for individual unidentified impurity (Result: ga %) on g for batch number (A) USP ya) ml, mya However, the failing batch remained in distribution in the US market. This batch failed again at 6-month long term stability timepoint due to individual unidentified impurity found at RRT ga (Result: gay %) (OOS Investigation: 33681). However, your firm did not recall the batch until ge from the US market. The protocol (A/Protocol/0069-000 and A/Protocol/0071-000) assessment revealed ®@ out of ®@ oatches were OOS. The details are as follows: Table 2 Sr. No. | Product Name | Batch number | Expiry date | Age of the batch when tested in Month (M) | Highest Individual Unidentified Impurity (Limit: NMToas an %) Your firm recalled the above ®@ batches from the US market between bo the | with a delay of about, since becoming aware of the failing test results. Your firm reported the root cause for obtaining failing test results for individual unidentified impurity at RRT about gy was due
Shortened here; the PDF has the full text.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 13 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training and experience required to perform their assigned functions.
Tablet or capsule weight variation
The in-process control procedures were deficient in that it did not include an examination of tablet and capsule weight variation.
Lack of quality control unit
There is no quality control unit.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Failing to test for penicillin cross-contamination
Non-penicillin drug products were not tested for the presence of penicillin, when a reasonable possibility existed that a non-penicillin drug product has been exposed to a cross-contamination with penicillin.
Show 8 more citations
Identification of containers, lines, equipment
All processing lines and major equipment used during the production of a batch of drug product is not properly identified at all times to indicate the phase of processing of the batch. Electronic signatures based on are used, but they do not meet the requirements of 21 CFR Part 11.
Written program not followed
The written stability testing program is not followed.
Following/documenting laboratory controls
Established laboratory control mechanisms are not documented at the time of performance.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components, in process materials and drug products.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 13 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Incomplete lab records; OOS reporting
OBSERVATION 1 Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, a) your QC laboratory does not report all test results from OOS investigations. CQA/057 Handling OOS Results states to report the average of six results. 1/00S/003/16 initiated for API raw Material "USP on January 12, 2016 stated to reported the average of repeat analysis. [illegible] USP was used in the manufacture of Capsules" "mg batch numbers and shipped to the US. b) your QC laboratory does not always report all in-specification test results. i) You retested [illegible] and mg/ mg/@ml exhibit batch number for assay after [illegible] of storage of solution and issued a second CoA reporting only the value of the second test even though the results of the first test were also in specification. ii) You retested [illegible] and mg/ mg @ml exhibit batch numbers. [illegible] [illegible] and [illegible] stability study 25°/60% RH 3 month for assay after [illegible] of storage of solution as part of [illegible] 2/0O0T/001/14. The incidence summary and final conclusion states to report the second test result. The first results were in-specification yet only the second results were reported.
- Observation 2
No adequate stability testing program
OBSERVATION 2 There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your Quality Assurance unit did not ensure you have stability data to support your shelf life dates and storage conditions in that: a) you do not use the same start date to assign the shelf life for your products as the date you use as day zero for your stability study program. AC/QC/001 Sampling, Testing and Data Compilation for Stability Study defines day zero for the stability study as the date of batch release. AC/QA/032 Assigning of Expiry Date defines the date the API is dispensed as the date/month for assigning the shelf life date. b) you do not always release batches to establish day zero for your stability studies in a timely manner. i) Packaging of [illegible] Tablets USP [illegible] was completed March 30, 2015. Initial testing was completed March 31, 2015. Final release of the batch, the date used to establish day zero for your stability study, occurred May 14, 2015. Batch release occurred 46 days after final packaging and 56 days from dispensing the API. ii) Stability Study Summary Reports for [illegible] Solution" "mg/mL exhibit batch [illegible] indicate initial testing for the batch packaged March 01, 2014 was conducted April 21, 2014, 50 days after packaging. The date reported on the stability study is March 03, 2014, 18 days after packaging. c) you did not ensure the container closure system used for Solution" "mg/mL provides protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Both control samples B (bottles) and stability study samples (bottles) of [illegible] Solution" "mg/mL batch stored in the [illegible] position appear to leak drug product.
Show observations 3 to 13
- Observation 3
Leaking container closure system
OBSERVATION 3 Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product. Specifically, the container closure system used to package [illegible] exhibit batch does not prevent product leakage. Both control samples (bottles) and stability study samples (bottles) of [illegible] Solution™ "mg/mL batch [illegible] stored in the [illegible] position appear to leak drug product. The [illegible] of all bottles also appear discolored from the drug product. Four of [illegible] cartons of control samples showed signs of leakage on the secondary carton and four of [illegible] cartons of stability study samples stored in the [illegible] position showed signs of apparent leakage on the secondary carton.
- Observation 4
Unsound sampling, specs, and stability changes
OBSERVATION 4 Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and sampling plans designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically; your sampling plans and stability testing timelines are not scientifically sound and changes to in-process and/or finished product specifications are not always scientifically valid in that: a) you [illegible] API raw material samples prior to testing: i) CQA/108 Raw Material, Sampling (Non Sterile) section 5.35 specifies a sample pooling procedure for the [illegible] sample for API raw material. Samples taken from [illegible] container are [illegible] prior to testing. ii) Section 5.37 specifies material received from other regulatory approved locations of Alkem Group, only description and identification test to be performed and the remaining results shall be entered into LIMS from the CoA received from respective location. Materials received from other Alkem Group facilities include APIs: [illegible] usp, USP, and Usp used in the manufacture of drug products shipped to the US. You do not conduct tests to identify inter and intra batch variation impacting drug product formulation for the above mentioned APIs. b) you [illegible] samples. AG/PV/14-021 Process Validation Protocol for [illegible] ded samples of the bulk solution before testing [illegible] samples were also [illegible] prior to testing including microbial sam[illegible]. c) CQA/098 Sampling Plan for Tablets includes samples obtained from the [illegible] and [illegible] after packaging for microbial testing prior to testing. d) A/DQ/15/006 deviation for stability sample analysis not completed within the timelines specified, initiated September 07, 2015, stated the root cause as a lack of manpower and a schedule. The investigation listed as a corrective action to change the timeline to test stability samples stored 40°/75% within [illegible] and the remaining stability samples within [illegible] to [illegible]%. No scientific rational was provided for changing the stability testing timelines. e) you changed the in-process and finished release content specification for [illegible] tablets, [illegible] (US market) from NMT [illegible] to NMT [illegible]% after an in-process sample out of specification result. No scientific rational was provided for changing the specification. f) you changed the release and shelf life [illegible] content specification for [illegible] tablets USP [illegible] Png and [illegible] mg after a finished product sample out of specification assay result. For Tablets USP [illegible] Png, and [illegible] mg the released specification was changed from NMT [illegible]% to NMT [illegible]% and the shelf life specification was changed from NMT [illegible]% to NMT [illegible]%. No scientific rational was provided for changing the specification.
- Observation 5
Equipment not qualified for sealing/leak
OBSERVATION 5 Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, you did conduct torque testing or leak tests as part of your equipment qualification — AG/P13Q-014 Performance | Qualification Protocol for [illegible] and Capping Machine. [illegible] Solution [illegible] mg/mL exhibit batch [illegible] manufactured using this equipment appears to leak as observed in control samples and stability study samples stored in your control sample room and stability chamber.
- Observation 6
Unjustified deviations; missing records
OBSERVATION 6 Deviations from written production and process control procedures are not justified. Specifically, you do not always record and justify deviations in that: a) expiration dates for APIs used in the manufacture of [illegible] and [illegible] mg mg/@ml exhibit batch numbers [illegible] and were not recorded on the batch record. No explanation was provided for not recording the expirations dates. b) there is no written indication in the batch record for [illegible] and [illegible] mg mg/| ml exhibit batch number that the assay after [illegible] of storage of solution was retested and a second CoA was issued. The second CoA reported the value of the second test only. The results of the first test and the second test were both in specification. c) you do not include an original or a copy of the original CoA with batch records, [illegible] and [illegible] mg mg @ml exhibit batch number included copy 1 of the CoA for this batch dated July 31, 2014. A second, copy 2 CoA for this batch dated September 09, 2014 reported a different result for the assay after [illegible] of storage of [illegible]olution. The date of copy 2 CoA was used as the stability study time zero date. Both results were in specification.
- Observation 7
Deficient distribution/recall traceability
OBSERVATION 7 The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary. Specifically, September 24, 2016 your SAP inventory system still showed an inventory of [illegible] bottles of [illegible] Solution" mg/mL. The Batch Packaging Record for Solution mg/mL indicated [illegible] bottles were transferred to the warehouse after packaging on March 01, 2014. Your SAP inventory records show [illegible] bottles of [illegible] Solution™ "mg/mL were received in the warehouse March 06, 2014. On September 21, 2016 I observed the actual count of bottles of [illegible] Solution" "mg/mL in your warehouses is [illegible] bottles. The SAP inventory system had [illegible] of [illegible] bottles moving out of the warehouse either September 21, 2016 or September 24, 2016.
- Observation 8
Inaccurate warehouse inventory records
OBSERVATION 8 Procedures describing the warehousing of drug products are not established and followed. Specifically, your warehouse SAP system does not always contain up-to-date and accurate information. A/WH/108 Bonded Store Room does not specify a time frame for updating the warehouse inventory system. On September 21, 2016 your SAP system showed [illegible] bottles of " Solution [illegible] mg/mL in inventory. The SAP system showed no movement of [illegible] Solution" "mg/mL from June 10, 2016 to September 24, 2016. The actual quantity in inventory on September 21, 2016 was [illegible] pottles. The SAP inventory system had no record of bottles moving out of the warehouse.
- Observation 9
Annual product quality reviews deficient
OBSERVATION 9 Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Specifically, you do not evaluate the quality standards of each drug product in that Annual Product Quality Reviews do not include year-to-year trending of critical processing parameters.
- Observation 10
QC unit lacks approval/rejection authority
OBSERVATION 10 The quality control unit lacks the responsibility and authority to approve and reject all drug products. Specifically, your Quality Assurance unit has not established, documented, and implemented an effective system for managing quality in that: a) REG/006 Field Alerts does not specify to evaluate the need to extend complaint investigations to other products. The procedure does not include a definition establishing day zero for complaints received. b) A1/MC/15/003 Market Complaint Investigation Report investigating complaints for [illegible] BN [illegible] mg/mL for batch numbers [illegible] contains results from testing batches of the same product manufactured in a previous campaign. The report did not include extending the investigation to other products using the same equipment.
- Observation 11
Electronic equipment calibration lapses
OBSERVATION 11 Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, digital counters tag no. [illegible] missed calibration according to the [illegible] instrument calibration calendar for [illegible] and Injection area. AC/EM/027 Calibration Schedule for Gauges and Instruments states that calibration can be done [illegible] from planned due date. The planned date for the calibration for Digital Counters tag no. [illegible] was listed as September 2, 2016 on the instrument calibration calendar and the status date was not recorded.
- Observation 12
Cleaning validation revalidation missing
OBSERVATION 12 Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used. Specifically, revalidation of the initial cleaning validation of [illegible] and [illegible] tablets manufactured in the [illegible] facility of block ([illegible] Block) was not performed as required by your written procedure. AC/QA/073 Cleaning Validation states revalidation shall be performed for periodic cleaning verification every [illegible]. The most recent Cleaning Validation Report for [illegible] and [illegible] Tablets [illegible] was approved on 04/29/2015.
- Observation 13
QC procedures/responsibilities not followed
OBSERVATION 13 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, a) CQA/005 Vendor Qualification of Raw Material does not specify how APIs are evaluated against the manufacturer’s CoA, what if any tests listed on the manufacturer’s CoA are conducted and if test methods used to verify the results on the manufacturer’s CoA are the same test methods used by the manufacturer. b) A/QC/105 Handling of Reference Standards, Preparation and Handling of Working Standards section 6.3.5 specifies all reference standards are stored in a refrigerator/incubator 2° — 8° C; section 6.5.18 specifies the current stock of reference standards is verified and documented [illegible] 3 and section 6.5.19 specifies expired reference standards are destroyed. On September 20, 2016 I observed expired USP reference standard [illegible] Related Substance Compound [illegible] used for method transfer testing HPLC impurity testing of [illegible] stored in freezer QC/340 at [illegible]. This expired standard was not discarded as required by your procedure and it was not listed on the Verification of Reference Standards Lots Updated List as required by your procedure. c) Written procedures, such as A/QC/117 Operation and Calibration of Dissolution Tester Make-Electrolab (TDT-08L), do not contain sufficient detail to ensure consistent performance of procedures. Dissolution testing is conducted on tablets and capsules such as [illegible] and [illegible] shipped to the U.S. On September 20, 2016 I observed dissolution testing for [illegible] Tablets [illegible] mg count batch number stability study 3 month on instrument QC/010 and determined samples were neither added nor [illegible] in a consistent and reproducible manner.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 2, 2026. Each one asked for a Form 483.
Inspection ending May 1, 2026Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 2, 2026FDA-FOIA-2026-6352Form 483Records released
- May 13, 2026FDA-FOIA-2026-4897Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 7 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.105Equipment identification1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.166Stability testing1 of 1
Show all 10
- 21 CFR 211.176Penicillin contamination1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006370524, one row per refused product line.
6 refusals from 2020-03-27 to 2025-09-22 · charged UNAPPROVED on 5, DR QUALITY on 1 · FDA sample analysis on 1
FDA firm profile- 2025-09-22
ATORVASTATIN CALCIUM (ANTI-CHOLESTEREMIC)61JCA08
DR QUALITY 501(b), 801(a)(3); ADULTERATION
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FDA sample analysis
Division of Northeast ImportsD82-2245271-5/31/1
- 2022-10-24
LACOSAMIDE (ANTI-CONVULSANT)61MCK47
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports9ES-0063345-1/11/1
- 2021-03-05
CLOZAPINE (SEDATIVE)65VCA13
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4068513-5/11/1
- 2020-06-17
METFORMIN (ANTI-DIABETIC)61PCA26
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7312001-5/11/2
- 2020-06-17
AMLODIPINE BESYLATE (ANTI-HYPERTENSIVE, PART II)62OCA14
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7312001-5/11/1
Show 1 more
- 2020-03-27
DOMPERIDONE61TDH31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-9293231-9/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Alkem Laboratories LimitedD-U-N-S 650066939
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Alkem Laboratories Limited (D-U-N-S 650066939) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Alkem Laboratories LimitedTehsil Nalagarh, Baddi, India · FEI 30063705339 inspections9latestMar 27, 2024VAINone on file
- Alkem Laboratories LimitedAnkleshwar, India · FEI 30084501722 inspections2latestDec 1, 2023VAINone on file
- Alkem Laboratories LimitedAnkleshwar, India · FEI 30068517963 inspections3latestApr 7, 2023NAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3006370524 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3006370524. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.