Alkem Laboratories Limited Form 483, May 2026
FDA issued this Form 483 to Alkem Laboratories Limited in India (FEI 3006370524) at the end of an inspection that ran from April 20 to May 1, 2026. It lists 1 observation.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 27, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection
- Apr 20–May 1, 2026
- Drug Product Manufacturer
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Jul 27, 2026
- 87 days after the inspection
The 1 observation on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate OOS/OOT investigations and recalls
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your investigations relating to Out of Specification (OOS) and Out of Trend (OOT) investigations are not thoroughly investigated and the CAPA taken is inadequate to determine the risk to the drug products sold into the US market. For example, A. Your OOS and OOT investigations for ge USP gy ml, and ga) mle AQ are not thoroughly investigated. For example, OOS Investigation Number: 157370, Date of Initiation ge) , Product: gq) USP gy ml ga Batch Number: gq , Mfg. date: , Expiry date: ga Stability Timepoint: 6-month long term stability condition (25°C/60%RH), Shelf life of product: gu Issue: Related Substances by HPLC test found OOS test result for individual unidentified impurity (due to an unknown peak at RRT about ga Result: ga %, Limit: NM Tg %, Investigation conclusion: Valid/Confirmed OOS. Your Quality Unit reported Field Alert (FAR/A/24/010) on ge to the agency but this annual stability batch gg was not recalled from the US market upon confirming OOS at 6-month stability timepoint. This batch failed again at 12-month stability time for the same individual unidentified impurity at RRT about wa (Result: gay %) on ke. Your firm initiated OOS investigation number 178824 for the 12-month failure and confirmed the test results as valid. Subsequently, your Quality Unit analyzed retention samples of ®@ USP gy) ml, and gg) mig through protocol (A/PCR/0506-000) and found OOT test results for out of; batches. The details are as follows: Table 1 Sr. No. | Batch number | Expiry date | Age of the batch when tested in Month (M) | Highest Individual Unidentified Impurity (Limit: [illegible] %) On gy , your firm recalled the above batches including the OOS batch g, gy with a delay of about gq from the date gq of becoming aware of the failing test results for ®@ USP ml. The delayed recall led to multiple batches either expiring in ®@ or nearing to its expiry gw (refer to Table 1). Furthermore, on ga your firm had conducted OOS investigation number: 6715 for individual unidentified impurity of annual stability batch failure at 3-month long term stability condition (25°C/60%RH), unidentified impurity (Result: gy@ %) for batch number ge. Product: ga USP mya ml, ma The OOS investigation concluded as valid OOS. However, the failing batch remained in distribution in the US market. This batch failed again at 9-month long term stability timepoint for individual unidentified impurity (Resultmye %) on me (OOS Investigation: 18622). However, your firm did not recall the batch until a from the US market. This was with a delay of about ga from the date of becoming aware of the failing test results for ge ®@ USP gy) ml. Moreover, your firm obtained valid OOS (OOS Investigation: 26190) test result at 3-month long term stability (25°C/60%RH) condition for individual unidentified impurity (Result: ga %) on g for batch number (A) USP ya) ml, mya However, the failing batch remained in distribution in the US market. This batch failed again at 6-month long term stability timepoint due to individual unidentified impurity found at RRT ga (Result: gay %) (OOS Investigation: 33681). However, your firm did not recall the batch until ge from the US market. The protocol (A/Protocol/0069-000 and A/Protocol/0071-000) assessment revealed ®@ out of ®@ oatches were OOS. The details are as follows: Table 2 Sr. No. | Product Name | Batch number | Expiry date | Age of the batch when tested in Month (M) | Highest Individual Unidentified Impurity (Limit: NMToas an %) Your firm recalled the above ®@ batches from the US market between bo the | with a delay of about, since becoming aware of the failing test results. Your firm reported the root cause for obtaining failing test results for individual unidentified impurity at RRT about gy was due
Shortened here; the PDF has the full text.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3006370524, newest first.
- Form 483, March 2018Inspection ended Mar 27, 2018 · Posted Apr 11, 2018VAI
- Form 483, September 2016Inspection ended Sep 29, 2016 · Posted Nov 29, 2016VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.