Skip to content

One Way Drug DBA Partell Specialty Pharmacy

5835 S Eastern Ave Ste 101, Las Vegas, Nevada, United States

FEI 3011769075

FDA has 2 inspections on file for One Way Drug DBA Partell Specialty Pharmacy in Las Vegas, Nevada (FEI 3011769075), from 2018 to 2019. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection. It is listed below.

The most recent OAI inspection ended on Mar 8, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2018–2019
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Hazardous drugs, prevention of cross-contamination

      You produced hazardous drugs without providing adequate containment, segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate/unsuitable sterilization agent

      The (b)(4) intended to render final product sterile is not adequate to accomplish sterilization and/or is not pharmaceutical grade. Specifically, a. Your firm uses the (b)(4) when compounding large volume batches of sterile finished product. The (b)(4) does not appear to be pharmaceutical grade and the labeling for the (b)(4) states "Do not use these systems in direct patient care applications." There is no (b)(4) testing method for the (b)(4). The firm releases finished drug product without determining the suitability of (b)(4). Examples of products, where the (b)(4) has been used as the (b)(4) are Coenzyme Q10, Ascorbic acid, and Vitamin B Complex. b. There is no assurance that the (b)(4) used to render drug product sterile is adequate to ensure the integrity of such (b)(4). Your firm was unable to confirm what required (b)(4) is used when performing (b)(4) testing on (b)(4). "There is a discrepancy with the required (b)(4) written in the (b)(4) test log and the manufacturer's requirement. For example, the log states (b)(4) required for the (b)(4), yet the manufacturer requires (b)(4). Your firm does not document the actual value in the Formula Worksheet and simply enters "PASS or FAIL."

    2. Observation 2

      Unverified sterilization cycle for pellets

      The cycle parameters (b)(4) used for (b)(4) of product intended to be sterile are not verified to be lethal to (b)(4) microorganisms. Specifically, a. Your firm performs all compounding and filling operations for (b)(4) pellet products in an unclassified Biosafety Cabinet, located in an unclassified room. Pellet products include: Estradiol, 10 mg, 12.5 mg, 15 mg, 20 mg, 25 mg, 35 mg, 40 mg, 50 mg, 55 mg Pellets; Naltrexone, 200 mg Pellets; Pregnenolone, 50 mg, 100 mg Pellets; Progesterone, 50 mg Pellets; Testosterone/Anastrozole 120/8 mg; 180/12 mg; 200/20 mg; 60/1 mg; 60/4 mg Pellets; Testosterone/Estradiol 60/6 mg Pellets; Testosterone 100 mg, 200 mg, 25 mg, 37.5 mg, 40 mg, 50 mg, 55 mg, 80 mg Pellets; Testosterone/Finasteride 60/5 mg, 80/8 mg Pellets; Testosterone/Finasteride/Anastrozole 120/10/4 mg Pellets. b. Your firm uses the (b)(4) for both (b)(4) sterilization and sterilization of container-closures, such as stoppers and final product vials. Effectiveness of (b)(4) is verified using (b)(4) Biological Indicators. The manufacturer recommends incubation conditions of (b)(4) for (b)(4). The incubator is not calibrated to ensure the temperature can maintain (b)(4). The (b)(4) does not contain a visual thermometer to monitor the temperature during BI incubation. c. Your firm conducts (b)(4) sterilization on sealed vials containing pellet products, using an (b)(4). There is no adequate scientific justification for the (b)(4) used to (b)(4) sterilize implantable pellets, including consideration of (b)(4) and the pellets themselves. There is no assurance that (b)(4) is adequate for pellets in sealed containers.

    Show observations 3 to 10
    1. Observation 3

      Containers/closures not depyrogenated

      The final containers/closures used for drug product intended to be sterile have not been sterilized or depyrogenated. Specifically, a. Your firm does not depyrogenate the non-sterile stoppers and vials before conducting filling operation for all aseptically filled drug products. b. Your firm does not depyrogenate the non-sterile stoppers and vials before conducting filling operation for all (b)(4) sterilized pellet drug products.

    2. Observation 4

      Non-sterile wipes/agents in ISO 5

      Disinfecting agents and cleaning pads or wipes used in the ISO 5 area are not sterile. Specifically, To clean and disinfect the ISO-5 Laminar Air Flow Hood (LAFH), the firm uses non-sterile (b)(4) Wipers, non-sterile (b)(4) Dry Wipes, non-sterile (b)(4), non-sterile (b)(4) and sterile (b)(4) spray.

    3. Observation 5

      Inadequate disinfectant contact times

      The use of sporicidal agents in the cleanrooms and/or ISO 5 areas is inadequate. Specifically, Your firm has not established sufficient contact time for all disinfectants use in the cleanroom. Your firm failed to follow manufacturer's recommended contact times for the disinfectants used in the controlled environments. For example, for non-sporicidal agent (b)(4) the manufacturer recommends a contact surface time of (b)(4). Your daily cleaning/disinfecting log for controlled environments and procedure, does not indicate contact times. Pharmacy Lab Manager and Technicians confirmed that after spraying (b)(4) on the surface, the solution is immediately removed. Demonstration of the effectiveness of the cleaning operations was not assessed due to lack of established contact times.

    4. Observation 6

      Non-dedicated utensils for hazardous drugs

      You produced hazardous drugs without providing adequate cleaning of utensils to prevent cross-contamination. Specifically, Your firm uses non-dedicated glassware and utensils to weigh and mix non-sterile hazardous and non-hazardous ingredients, in preparation for aseptic filling operations. Examples of hazardous ingredients used in your facility include Testosterone Cypionate and Alprostadil.

    5. Observation 7

      Tools not sterilized/depyrogenated

      Non-sterilized or non-depyrogenated tools or temporary container were used in sterile production. Specifically, Your firm uses glassware and utensils to weigh and mix non-sterile ingredients, in preparation for aseptic filling operations. Your firm does not adequately clean the glassware and utensils to prevent cross-contamination. Glassware, spatulas, and mixing bars are washed in a dishwasher using (b)(4). Your firm has not conducted any testing (microbial and analytical) of the water generated through your (b)(4) system. The glassware is placed in (b)(4). There is no assurance that these conditions [illegible] sterilization or depyrogenation these materials prior to use in compounding sterile drug products.

    6. Observation 8

      Inadequate environmental monitoring

      Environmental monitoring in your aseptic processing areas is not adequate. Specifically, a. Review of the last (b)(4) Environmental Monitoring report, dated 11/30/17, revealed that Micrococcus species and Aspergillus was detected when viable air sampling was conducted in the ISO-5 Laminar Air Flow Hood. As a corrective action, your firm performed cleaning (b)(4) times in the controlled environment, and air sampling was repeated. An investigation was not conducted and a root cause was not determined. b. (b)(4) surface sampling is part of the firm's Environmental Monitoring program. Surface samples are taken with (b)(4), immediately after spraying sterile (b)(4) on the surface.

    7. Observation 9

      Inadequate pressure differentials/doors

      Inadequate pressure differentials between higher quality air rooms and lower quality air rooms were observed. Specifically, a. Sterile drug filling is conducted inside the ISO 5 core of Laminar Air Flow Hood (LAFH). The evaluation of unidirectional airflow (e.g., smoke studies) for microbiological contamination was not performed under dynamic conditions in the ISO 5 LAFH, which is located in an ISO 7 environment. b. During filling operations, we observed that the doors from the ISO 8 compounding room to the ISO 7 Ante room; and the door from the ISO ? Ante-Room to the ISO 7 aseptic filling room, did not stay consistently closed. We heard multiple alarms during the aseptic filling due to loss in pressure. The firm cannot assure continuous positive pressure during filling operations.

    8. Observation 10

      Inadequate media fills; sterility OOS

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, (b)(4) media fill testing is performed, but are not designed to simulate firm's routine aseptic operation. a. Your firm conducts Media Fill in (b)(4). A commercially purchased kit containing (b)(4) are used to conduct media fills. The content of the (b)(4) of this solution is (b)(4). This procedure is repeated (b)(4) times. This does not simulate their filling process. The bag is not representative of the container/closures used during routine production. b. When filling large batch size sterile products, the firm uses a fluid dispensing pump. For example, the fluid dispensing pump is used during filling of Methylcobalamin, 12.5 mg/ml injection, whose batch size is (b)(4) into 50 ml vials or 500 ml into 5 ml vials. This pump is not included during the media fill simulation. You have a sterility failure as evidence of production under insanitary conditions. Your firm conducted an inadequate Sterility OOS investigation. Review of OOS Sterility failure investigation revealed Bacillus species was detected in (b)(4). The firm's corrective action includes cleaning and disinfecting the controlled environment (b)(4) times. Demonstration of the effectiveness of the cleaning operations was not assessed because environmental and personnel monitoring was not performed afterward.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011769075 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011769075. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.