Park Infusioncare LP dba Preferred Homecare Form 483, February 2017

FDA issued this Form 483 to Park Infusioncare LP dba Preferred Homecare in Houston, Texas (FEI 3012669716) at the end of a drug inspection that ended February 17, 2017. It lists 2 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 17, 2017
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,525 days after the inspection
Facility
FEI 3012669716
Houston, Texas

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Facility allows poor air influx

    OBSERVATION 1 The facility design and maintenance was observed to allow the influx of poor quality air into a higher classified area. 1) Your firm has a number of structural and maintenance deficiencies in classified areas. These are summarized below: a. One of the ISO 5 hoods ("HOOD J") in the ISO 7 cleanroom has a work surface made of wood covered with what appears to be formica, with visible residues and abrasions on the surface. The Nurse Manager acknowledged that this surface is not amenable to suitable cleaning. b. One of the ISO 5 hoods ("HOOD H") exhibited a crack in the plexi-glass like side panel. This same ISO 5 hood exhibited an accumulation of dust above the hood. c. One of the ISO 5 hoods ("HOOD") displayed reddish-brown discoloration consistent with rust along the right and left corners of the interior of the hood. The majority of the HEPA filter for ISO 5 hood exhibited an orange-red discoloration. d. In the ISO 7 cleanroom there are observable gaps between the HEPA filters and the ceilings. Some gaps were mended with tape. Four of nine tiles above were observed displaced in the ISO 7 cleanroom such that there was a continuous space between the ISO 7 cleanroom and the unclassified area above the ceiling. e. The wall in the ISO 7 cleanroom was a distorted/damaged wall with a brownish tinge. f. The ISO 7 anteroom has a ceiling made of ceiling tiles like found in an office space. Gaps were observed around ceiling tile and the HEPA filter in the ceiling of the ISO 7 anteroom such that there was a continuous space between the ISO 7 anteroom and the unclassified area above the ceiling. Additionally, the HEPA filter appeared distorted at the edge of the filter. g. The sink in the ISO 7 anteroom has a work surface made of wood covered either with what appears to be formica and in an apparent rough, unfinished state. The Nurse Manager acknowledged that this surface is not amenable to suitable cleaning. h. Wooden doors separate the anteroom and cleanroom. This surface is not amenable to cleaning. 2) The firm lacks the following items to assess the acceptability of the air quality: a. Pressure differentials between the ISO 7 and ISO 5 areas and the unclassified and ISO 7 areas are not actively monitored or recorded to ensure positive pressure is maintained during sterile drug manipulation activities. Furthermore, the pressure gauges between the ISO 7 cleanroom and ISO 7 anteroom areas and the ISO 7 anteroom and unclassified areas had not been calibrated to ensure accurate pressure readings. As such during the months of September, October and November of 2016 pressures in the anteroom appeared negative relative to the cleanroom. During this time, your firm continued aseptic processing of drug products. Your firm purported that there are not accurate pressure readings prior to identifying this negative pressure in the anteroom after an extended period of time. During the months of September, October and November of 2016, (6) (4) aseptically processed units had been dispensed. b. Documented pressure differentials could not be explained. From August 2016 to February 2017, pressure differentials (biggest and lowest recorded values) of the classified areas can be found in the table below: Value Cleanroom Anteroom ChemoRoom Represented (b) (4) (b) (4) Highest pressure recorded (inWC) (b)(4) Lowest pressure recorded (inWC) It was observed that air pressure in the ISO 7 cleanroom forced ceiling tiles to become displaced, exposing the ISO 7 cleanroom to the unclassified area above the ceiling. 2) The firm contracts (15)(4) to perform room certification. During the certification date (b) (4) (the latest certification) and discussion with the associated technician the following deficiencies were documented: a. Dynamic smoke studies were not conducted. Furthermore, there is no evidence that smoke studies have been conducted in the ISO 7, and ISO 5 areas. b. The entire certification report was conducted under static conditions, and is

    Shortened here; the PDF has the full text.

  2. 2

    Inadequate sporicidal use in hoods

    OBSERVATION 2 The use of sporicidal agents in the cleanrooms and/or ISO 5 areas is inadequate or infrequent. On 02/14/2017, your Pharmacist-in-Charge stated that a sporicidal agent is not utilized to disinfect the ISO 5 hoods. Specifically, your firm stated only [illegible] is used to clean ISO 5 hoods used for aseptic processing.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.