Preferred Homecare (Park Infusioncare LP)
4007 Bellaire Blvd Ste G, Houston, Texas, United States
FEI 3012669716
FDA has one inspection on file for Preferred Homecare (Park Infusioncare LP) in Houston, Texas (FEI 3012669716). It ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Apr 21, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2017
- Inspections with 483 observations shown
- 1 of 1
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance2 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Facility allows poor air influx
OBSERVATION 1 The facility design and maintenance was observed to allow the influx of poor quality air into a higher classified area. 1) Your firm has a number of structural and maintenance deficiencies in classified areas. These are summarized below: a. One of the ISO 5 hoods ("HOOD J") in the ISO 7 cleanroom has a work surface made of wood covered with what appears to be formica, with visible residues and abrasions on the surface. The Nurse Manager acknowledged that this surface is not amenable to suitable cleaning. b. One of the ISO 5 hoods ("HOOD H") exhibited a crack in the plexi-glass like side panel. This same ISO 5 hood exhibited an accumulation of dust above the hood. c. One of the ISO 5 hoods ("HOOD") displayed reddish-brown discoloration consistent with rust along the right and left corners of the interior of the hood. The majority of the HEPA filter for ISO 5 hood exhibited an orange-red discoloration. d. In the ISO 7 cleanroom there are observable gaps between the HEPA filters and the ceilings. Some gaps were mended with tape. Four of nine tiles above were observed displaced in the ISO 7 cleanroom such that there was a continuous space between the ISO 7 cleanroom and the unclassified area above the ceiling. e. The wall in the ISO 7 cleanroom was a distorted/damaged wall with a brownish tinge. f. The ISO 7 anteroom has a ceiling made of ceiling tiles like found in an office space. Gaps were observed around ceiling tile and the HEPA filter in the ceiling of the ISO 7 anteroom such that there was a continuous space between the ISO 7 anteroom and the unclassified area above the ceiling. Additionally, the HEPA filter appeared distorted at the edge of the filter. g. The sink in the ISO 7 anteroom has a work surface made of wood covered either with what appears to be formica and in an apparent rough, unfinished state. The Nurse Manager acknowledged that this surface is not amenable to suitable cleaning. h. Wooden doors separate the anteroom and cleanroom. This surface is not amenable to cleaning. 2) The firm lacks the following items to assess the acceptability of the air quality: a. Pressure differentials between the ISO 7 and ISO 5 areas and the unclassified and ISO 7 areas are not actively monitored or recorded to ensure positive pressure is maintained during sterile drug manipulation activities. Furthermore, the pressure gauges between the ISO 7 cleanroom and ISO 7 anteroom areas and the ISO 7 anteroom and unclassified areas had not been calibrated to ensure accurate pressure readings. As such during the months of September, October and November of 2016 pressures in the anteroom appeared negative relative to the cleanroom. During this time, your firm continued aseptic processing of drug products. Your firm purported that there are not accurate pressure readings prior to identifying this negative pressure in the anteroom after an extended period of time. During the months of September, October and November of 2016, (6) (4) aseptically processed units had been dispensed. b. Documented pressure differentials could not be explained. From August 2016 to February 2017, pressure differentials (biggest and lowest recorded values) of the classified areas can be found in the table below: Value Cleanroom Anteroom ChemoRoom Represented (b) (4) (b) (4) Highest pressure recorded (inWC) (b)(4) Lowest pressure recorded (inWC) It was observed that air pressure in the ISO 7 cleanroom forced ceiling tiles to become displaced, exposing the ISO 7 cleanroom to the unclassified area above the ceiling. 2) The firm contracts (15)(4) to perform room certification. During the certification date (b) (4) (the latest certification) and discussion with the associated technician the following deficiencies were documented: a. Dynamic smoke studies were not conducted. Furthermore, there is no evidence that smoke studies have been conducted in the ISO 7, and ISO 5 areas. b. The entire certification report was conducted under static conditions, and is
Shortened here; the PDF has the full text.
- Observation 2
Inadequate sporicidal use in hoods
OBSERVATION 2 The use of sporicidal agents in the cleanrooms and/or ISO 5 areas is inadequate or infrequent. On 02/14/2017, your Pharmacist-in-Charge stated that a sporicidal agent is not utilized to disinfect the ISO 5 hoods. Specifically, your firm stated only [illegible] is used to clean ISO 5 hoods used for aseptic processing.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012669716 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012669716. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.