FDA has 7 inspections on file for Eugia Pharma Specialities Limited in Sangareddy, India (FEI 3008461619), from 2012 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the six FOIA requests for this site has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, EUGIA Pharma Specialities Limited (D-U-N-S 650804896), has registered 4 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
7, 2012–2026
2 OAI · 4 VAI · 1 NAI
Inspections with 483 observations shown
5 of 7
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
6 posted
Requested under FOIA
6 requests, latest Jul 18, 2024
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Sterility/pyrogens - test methods written, followed

      Test procedures relative to appropriate laboratory testing for pyrogens are not followed.

    4. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    Show 6 more citations
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy.

    5. Following/documenting laboratory controls

      Established laboratory control mechanisms are not followed.

    6. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Changes to Procedures Not Reviewed, Approved

      Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    4. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    Show 4 more citations
    1. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    2. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic equipment not maintained

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, on February 13, 2018 during the machine set-up and filling preparation for ®® | injection lot # ®®, I observed dirty ®® | with black stains on the filling machine and mentioned it to the management. No action was taken by the management on that day. On Feb. 14, 2018, I observed that the filling is in process and the dirty ®® is in use. Despite of informing the management of the dirty ®® by me, the management failed to take action to investigate the dirt on the ®® and to remove the ®® | with potential quality impact on the drug product. The filling of the lot was completed in the .

    2. Observation 2

      Equipment cleaning intervals inadequate

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, on the filling machine in suite § which are used for aseptic interventions during the filling operation inside the aseptic fill zone (grade A) had obvious built-up dirt and stains. These ®® | are used for production of injection since June 2017.

    Show observations 3 to 9
    1. Observation 3

      Vial washer qualification inadequate

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the qualification of the vial washer and in®® block suite, that are used for washing and sterilizing of § mL vials are not adequate. For example, qualification studies: a) for vial washer failed to demonstrate if vial washer (Eq. Id. # L-PR-QASHM-001) is able to remove bioburden from f mL glass vials that are used for filling and ®® of | injection. b) failed to use statistically sound number of vials to demonstrate the effectiveness of the wash cycle and®® processes. 1. During the qualification study of the vial washer, you conducted one run cycle using @ vials of {§ mL glass vials as the representative of the lot and spiked those with | to demonstrate the cleaning of the vials after wash. You placed these vials in the ®¢ of the wash cycle. The batch of the vials used for this study included ®® vials. You used less than 1% of the lot to demonstrate the cleaning. A commercial lot size for” injection contains POT vials. 2. During the qualification study of the , you spiked {| @ mL glass vials with endotoxin and performed one run to demonstrate the effectiveness of the ®“ in reduction of endotoxin level in those vials. You placed vials in ®® different rows; ®® row before - @ . - vials entering the ®® These f§)| vials represented a batch of ®® vials and were less than 1% of total vials. Currently you use this ®® to ®® about vials for a production of a commercial lot of ®® injection.

    2. Observation 4

      Facility vermin infestation observed

      Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin. Specifically, during the walkthrough of the facility on February 12, 2018, a large mosquito which appeared to be a female, was observed inside room , Semi-finished product storage area holding. This room is located inside the unclassified but controlled environment corridor (corridor-1) and is connected to room . collection vials for visual inspection. To reach this room personnel B ®@ should pass)’ sets of doors ©) 0) - - — ]. This room is two sets of doors away from the grade “B” and grade “A” areas where the filling and activities for ®@ injection takes place.

    3. Observation 5

      Cleaning procedures lack necessary detail

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. Specifically, your firm failed to demonstrate the efficacy of the 2 process, which is part of your cleaning activities, to eliminate contaminants in the hard to reach areas in the aseptic fill and areas (grade A & B).

    4. Observation 6

      Personnel training deficiencies observed

      Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, during the machine set-up and filling preparation for ® injection lot # | on February 13, 2018, I observed that two operators inside the cleanroom cleaned the ©O@ that were already installed on the filling machine’s :P@ times with ®® and cloth without paying attention to the black stains and obvious black marks on the ®® These ®® were in use from June 2017 and had been sterilized 5 times.

    5. Observation 7

      Sampling plan lacks clear acceptance criteria

      The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels. Specifically, your procedure for receiving and inspection of the components and packaging materials (procedure # FU4-QC-GEN-026, Sampling of packing materials) follows an unspecified level of AQL of ANSI Z1.4-2008 with no clear criteria for acceptance and rejection level. This procedure is deficient to provide clear reject and acceptance levels based on ANSI Z1.4-2008.

    6. Observation 8

      Laboratory standard handling deficient

      Established laboratory control mechanisms are not followed and documented at the time of performance. Specifically, laboratory control is deficient in that USP reference standards, code #USP- | with lot #% , used to determine the identity, strength, quality and purity of ® | injection which were received in laboratory on January 11, 2018: a) were not received in laboratory inventory management system (LIMS) as required by your procedure, however they were stored in the same container as other standards which were previously received and were in use. b) were not placed in desiccator as it is recommended on the COA.

    7. Observation 9

      Inadequate control over electronic records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, master batch records that are submitted in“ for | injection, have different batch codes (document number) than the batch records that are currently in use for commercial production. There are no traceability for the changes made to the batches used for commercial production and master batch records that are submitted in the o@

  5. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Field Alert not filed for stopper defect

      An Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product. Specifically, your firm has received six complaints pertaining to four separate batches of the sterile human drug (b) (4) Injectable (b) (4) mg (b) (4) mL that describe the (b) (4) stopper pushing into the vial upon spiking with infusion sets. Complaints were received between March and September 2016. No Field Alert has been filed for this issue by your firm. Additionally, your own investigation (report "Final Investigation Report" dated September 1, 2016 and report #PRD-INV-0001-16-00) verified that the (b) (4) stoppers can be pushed into the vials, thus making the drug product un-usable.

    2. Observation 2

      Inadequate laboratory test procedures pooling samples

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity. Specifically, your written test procedures for assay and related substances for all sterile injectable drug products intended for the US market utilize (b) (4) of (b) (4) unit containers in sample preparation (b) (4) HPLC analysis with the justification that (b) (4) reduces the variability of results. The following examples from (b) (4) total US products and associated test methods are affected: 1. (b) (4) Injection - (b) (4) vials used - STP #(b) (4) 2. (b) (4) Injection - (b) (4) vials - STP #(b) (4) 3. (b) (4) Injection - (b) (4) vials - STP #(b) (4) 4. (b) (4) Injection - (b) (4) vials - STP #(b) (4)

    Show observations 3 to 4
    1. Observation 3

      Inadequate equipment qualification and procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, the qualification of equipment is not adequate for its intended purpose including (b) (4) vial stoppering machine, and (b) (4) equipment. A. The Line #(b) (4) stoppering equipment qualification document # SH1026OQ Rev 1.0 and FU4-PN-(b) (4)-001-EQP-PQ-002 does not include a quantitative evaluation of the (b) (4) for products intended for (b) (4). During the inspection on September 7, I observed a large number (b) (4) of product vials with dislodged and variable (b) (4) (b) (4) during production of Injection (batch (b) (4). B. The (b) (4) 002 re-qualification document FU4-PN (b) (4) 002-EQP-RQ-001 and product validation reports such as FU4-SIPO-PVR-004) do not speak to the (b) (4) pressure needed to (b) (4) up to (b) (4) vials in a single load occupying (b) (4). This operation is currently controlled by visual indication of (b) (4) through (b) (4) approximate (b) (4) as instructed by SOP #FU4-PR-MF-OPI-090. C. The drawing of (b) (4) -40 #L11008Ca-001-01-03 revision 1, provided by the supplier, indicates the equipment should be installed with a (b) (4) unit connected to the (b) (4) valve connection (b) (4) 315. This (b) (4) item is not installed on the equipment. D. (b) (4) system drawing #APL-IV/EN/ (b) (4) 002-14 does not show installed equipment such as (b) (4) in Line #(b) (4) compounding area. This (b) (4) system is used to operate (b) (4) valves and (b) (4) media through equipment during simulations. E. (b) (4) tank drawing #APL-IV/EN (b) (4) 001-07 and (b) (4) tank drawing #APL-IV/EN (b) (4) 002-01 are inaccurate with respect to the order and location of piping such as (b) (4) (b) (4) and (b) (4). The (b) (4) in these tanks is used for (b) (4) equipment and compounding of drug products (respectively) such as injectables and (b) (4) products.

    2. Observation 4

      SCADA temperature monitoring system malfunctioning

      The use of instruments and recording devices not meeting established specifications was observed. Specifically, the "Indu Softweb Studio" SCADA electronic recording system for temperatures found in the micro lab rooms for incubating Environmental Monitoring, Reference Cultures, and other media incubation shows multiple out-of-specification temperatures and loss of communication errors through June, July, and August 2016. As evidenced by repeated communication failures and out-of-specification data within a three month period, this equipment is not functioning adequately and has not been maintained to the criteria set in the qualification protocol #10443-01.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Jul 18, 2024.

  • Inspection ending Feb 6, 2026OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Date not givenFDA-FOIA-2026-1309Form 483Records released
  • Inspection ending Feb 2, 2024OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 18, 2024FDA-FOIA-2024-6313Inspection recordsWithdrawn
  • Inspection ending Nov 13, 2019

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Oct 10, 2023FDA-FOIA-2023-8844Form 483Closed
  • Inspection date not given

    3 requests. None of FDA’s log entries for these requests say records were released.

    1. Feb 7, 2024FDA-FOIA-2024-1364Form 483Closed
    2. Feb 5, 2024FDA-FOIA-2024-1241Form 483Closed
    3. Feb 2, 2024FDA-FOIA-2024-1159Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 7 inspections, with how many of them cited each.

Show all 13

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
EUGIA Pharma Specialities LimitedD-U-N-S 650804896

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names EUGIA Pharma Specialities Limited (D-U-N-S 650804896) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3008461619 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3008461619. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.