Skip to content

Aurobindo Pharma Limited Unit 4 Form 483, September 2016

FDA issued this Form 483 to Aurobindo Pharma Limited Unit 4 in Sangareddy, India (FEI 3008461619) at the end of a drug inspection that ended September 16, 2016. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Dec 15, 2016. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 16, 2016
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Dec 15, 2016
90 days after the inspection
Facility
FEI 3008461619
Sangareddy, India

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Field Alert not filed for stopper defect

    An Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product. Specifically, your firm has received six complaints pertaining to four separate batches of the sterile human drug (b) (4) Injectable (b) (4) mg (b) (4) mL that describe the (b) (4) stopper pushing into the vial upon spiking with infusion sets. Complaints were received between March and September 2016. No Field Alert has been filed for this issue by your firm. Additionally, your own investigation (report "Final Investigation Report" dated September 1, 2016 and report #PRD-INV-0001-16-00) verified that the (b) (4) stoppers can be pushed into the vials, thus making the drug product un-usable.

  2. 2

    Inadequate laboratory test procedures pooling samples

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity. Specifically, your written test procedures for assay and related substances for all sterile injectable drug products intended for the US market utilize (b) (4) of (b) (4) unit containers in sample preparation (b) (4) HPLC analysis with the justification that (b) (4) reduces the variability of results. The following examples from (b) (4) total US products and associated test methods are affected: 1. (b) (4) Injection - (b) (4) vials used - STP #(b) (4) 2. (b) (4) Injection - (b) (4) vials - STP #(b) (4) 3. (b) (4) Injection - (b) (4) vials - STP #(b) (4) 4. (b) (4) Injection - (b) (4) vials - STP #(b) (4)

  3. 3

    Inadequate equipment qualification and procedures

    There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, the qualification of equipment is not adequate for its intended purpose including (b) (4) vial stoppering machine, and (b) (4) equipment. A. The Line #(b) (4) stoppering equipment qualification document # SH1026OQ Rev 1.0 and FU4-PN-(b) (4)-001-EQP-PQ-002 does not include a quantitative evaluation of the (b) (4) for products intended for (b) (4). During the inspection on September 7, I observed a large number (b) (4) of product vials with dislodged and variable (b) (4) (b) (4) during production of Injection (batch (b) (4). B. The (b) (4) 002 re-qualification document FU4-PN (b) (4) 002-EQP-RQ-001 and product validation reports such as FU4-SIPO-PVR-004) do not speak to the (b) (4) pressure needed to (b) (4) up to (b) (4) vials in a single load occupying (b) (4). This operation is currently controlled by visual indication of (b) (4) through (b) (4) approximate (b) (4) as instructed by SOP #FU4-PR-MF-OPI-090. C. The drawing of (b) (4) -40 #L11008Ca-001-01-03 revision 1, provided by the supplier, indicates the equipment should be installed with a (b) (4) unit connected to the (b) (4) valve connection (b) (4) 315. This (b) (4) item is not installed on the equipment. D. (b) (4) system drawing #APL-IV/EN/ (b) (4) 002-14 does not show installed equipment such as (b) (4) in Line #(b) (4) compounding area. This (b) (4) system is used to operate (b) (4) valves and (b) (4) media through equipment during simulations. E. (b) (4) tank drawing #APL-IV/EN (b) (4) 001-07 and (b) (4) tank drawing #APL-IV/EN (b) (4) 002-01 are inaccurate with respect to the order and location of piping such as (b) (4) (b) (4) and (b) (4). The (b) (4) in these tanks is used for (b) (4) equipment and compounding of drug products (respectively) such as injectables and (b) (4) products.

  4. 4

    SCADA temperature monitoring system malfunctioning

    The use of instruments and recording devices not meeting established specifications was observed. Specifically, the "Indu Softweb Studio" SCADA electronic recording system for temperatures found in the micro lab rooms for incubating Environmental Monitoring, Reference Cultures, and other media incubation shows multiple out-of-specification temperatures and loss of communication errors through June, July, and August 2016. As evidenced by repeated communication failures and out-of-specification data within a three month period, this equipment is not functioning adequately and has not been maintained to the criteria set in the qualification protocol #10443-01.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3008461619, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.