Eugia Pharma Specialities Limited Form 483, February 2026
FDA issued this Form 483 to Eugia Pharma Specialities Limited in Sangareddy, India (FEI 3008461619) at the end of a drug inspection that ended February 6, 2026. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Feb 12, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Feb 6, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Feb 12, 2026
- 6 days after the inspection
FDA's 11 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Sterility/pyrogens - test methods written, followed
Test procedures relative to appropriate laboratory testing for pyrogens are not followed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3008461619, newest first.
- Form 483, February 2024Inspection ended Feb 2, 2024 · Posted Feb 13, 2024OAI
- Form 483, December 2018Inspection ended Dec 14, 2018 · Posted Feb 25, 2019VAI
- Form 483, February 2018Inspection ended Feb 20, 2018 · Posted Mar 6, 2018VAI
- Form 483, April 2017FDA record date Apr 28, 2017 · Posted May 8, 2017
- Form 483, September 2016Inspection ended Sep 16, 2016 · Posted Dec 15, 2016VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.