Aurobindo Pharma Ltd. Form 483, February 2018
FDA issued this Form 483 to Aurobindo Pharma Ltd. in Sangareddy, India (FEI 3008461619) at the end of a drug inspection that ended February 20, 2018. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 6, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Feb 20, 2018
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Mar 6, 2018
- 14 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Aseptic equipment not maintained
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, on February 13, 2018 during the machine set-up and filling preparation for ®® | injection lot # ®®, I observed dirty ®® | with black stains on the filling machine and mentioned it to the management. No action was taken by the management on that day. On Feb. 14, 2018, I observed that the filling is in process and the dirty ®® is in use. Despite of informing the management of the dirty ®® by me, the management failed to take action to investigate the dirt on the ®® and to remove the ®® | with potential quality impact on the drug product. The filling of the lot was completed in the .
- 2
Equipment cleaning intervals inadequate
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, on the filling machine in suite § which are used for aseptic interventions during the filling operation inside the aseptic fill zone (grade A) had obvious built-up dirt and stains. These ®® | are used for production of injection since June 2017.
- 3
Vial washer qualification inadequate
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the qualification of the vial washer and in®® block suite, that are used for washing and sterilizing of § mL vials are not adequate. For example, qualification studies: a) for vial washer failed to demonstrate if vial washer (Eq. Id. # L-PR-QASHM-001) is able to remove bioburden from f mL glass vials that are used for filling and ®® of | injection. b) failed to use statistically sound number of vials to demonstrate the effectiveness of the wash cycle and®® processes. 1. During the qualification study of the vial washer, you conducted one run cycle using @ vials of {§ mL glass vials as the representative of the lot and spiked those with | to demonstrate the cleaning of the vials after wash. You placed these vials in the ®¢ of the wash cycle. The batch of the vials used for this study included ®® vials. You used less than 1% of the lot to demonstrate the cleaning. A commercial lot size for” injection contains POT vials. 2. During the qualification study of the , you spiked {| @ mL glass vials with endotoxin and performed one run to demonstrate the effectiveness of the ®“ in reduction of endotoxin level in those vials. You placed vials in ®® different rows; ®® row before - @ . - vials entering the ®® These f§)| vials represented a batch of ®® vials and were less than 1% of total vials. Currently you use this ®® to ®® about vials for a production of a commercial lot of ®® injection.
- 4
Facility vermin infestation observed
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin. Specifically, during the walkthrough of the facility on February 12, 2018, a large mosquito which appeared to be a female, was observed inside room , Semi-finished product storage area holding. This room is located inside the unclassified but controlled environment corridor (corridor-1) and is connected to room . collection vials for visual inspection. To reach this room personnel B ®@ should pass)’ sets of doors ©) 0) - - — ]. This room is two sets of doors away from the grade “B” and grade “A” areas where the filling and activities for ®@ injection takes place.
- 5
Cleaning procedures lack necessary detail
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. Specifically, your firm failed to demonstrate the efficacy of the 2 process, which is part of your cleaning activities, to eliminate contaminants in the hard to reach areas in the aseptic fill and areas (grade A & B).
- 6
Personnel training deficiencies observed
Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions. Specifically, during the machine set-up and filling preparation for ® injection lot # | on February 13, 2018, I observed that two operators inside the cleanroom cleaned the ©O@ that were already installed on the filling machine’s :P@ times with ®® and cloth without paying attention to the black stains and obvious black marks on the ®® These ®® were in use from June 2017 and had been sterilized 5 times.
- 7
Sampling plan lacks clear acceptance criteria
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels. Specifically, your procedure for receiving and inspection of the components and packaging materials (procedure # FU4-QC-GEN-026, Sampling of packing materials) follows an unspecified level of AQL of ANSI Z1.4-2008 with no clear criteria for acceptance and rejection level. This procedure is deficient to provide clear reject and acceptance levels based on ANSI Z1.4-2008.
- 8
Laboratory standard handling deficient
Established laboratory control mechanisms are not followed and documented at the time of performance. Specifically, laboratory control is deficient in that USP reference standards, code #USP- | with lot #% , used to determine the identity, strength, quality and purity of ® | injection which were received in laboratory on January 11, 2018: a) were not received in laboratory inventory management system (LIMS) as required by your procedure, however they were stored in the same container as other standards which were previously received and were in use. b) were not placed in desiccator as it is recommended on the COA.
- 9
Inadequate control over electronic records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, master batch records that are submitted in“ for | injection, have different batch codes (document number) than the batch records that are currently in use for commercial production. There are no traceability for the changes made to the batches used for commercial production and master batch records that are submitted in the o@
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3008461619, newest first.
- Form 483, February 2026Inspection ended Feb 6, 2026 · Posted Feb 12, 2026OAI
- Form 483, February 2024Inspection ended Feb 2, 2024 · Posted Feb 13, 2024OAI
- Form 483, December 2018Inspection ended Dec 14, 2018 · Posted Feb 25, 2019VAI
- Form 483, April 2017FDA record date Apr 28, 2017 · Posted May 8, 2017
- Form 483, September 2016Inspection ended Sep 16, 2016 · Posted Dec 15, 2016VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.