FDA has 3 inspections on file for Eugia Pharma Specialities Limited in India (FEI 3011960448), from 2022 to 2026. The latest ended on ; FDA has not posted its classification yet. FDA issued a warning letter on (CDER).

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, EUGIA Pharma Specialities Limited (D-U-N-S 650804896), has registered 4 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
3, 2022–2026
0 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
1 of 3
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest May 11, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic/monitoring controls

      OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, 1. Environmental and personnel monitoring are not appropriately established. The aseptic connection for connecting the (b)(4) vessel for L (b)(4) was performed within the LAF on line (b)(4) July 2025 with bacterial alert and action limits of (b)(4) and (b)(4), respectively. The area is not held to Grade A classification during this critical operation with a specification of No Growth. There is no immediate personnel monitoring conducted for the individual after completing the aseptic connection. 2. The (b)(4) on the sterile filling lines in the (b)(4) installed by the operator (b)(4) Grade A filling area then (b)(4) filling area (b)(4) touch the Grade A exposed portion of the (b)(4) and are not sanitized. 3. The conveyor on Line (b)(4) at the stoppering station is (b)(4). The (b)(4) intervention and entering the area to access the other side of the line resulted in the following deficiencies observed: a. The intervention was not performed according to procedure, which requires that only (b)(4) b. Operations personnel are not personnel monitored after this intervention during filling operations. c. The areas under the (b)(4) were not completely disinfected after reassembly of (b)(4). In addition, Line (b)(4) has a conveyor which is (b)(4). Similar deficiencies were observed with this intervention and Line (b)(4) is qualified up for set-up and filling operations. 4. During the review of CCTV footage for (b)(4) (b)(4) Img/ml Batch (b)(4) observed: a. During the aseptic connection the sterile product transfer line (b)(4) b. Interventions including removal of fallen vials (b)(4) did not ensure that (b)(4).

    2. Observation 2

      No recent media fill validation

      OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, There has been no aseptic process simulation (media fill) conducted since July 2022 for (b)(4). (b)(4) requires (b)(4) using Line (b)(4) connection (b)(4) and is used to perform filling on the filling line. Since March 2024, at least (b)(4) -7 mg/ml have been shipped to the (b)(4).

    Show observations 3 to 4
    1. Observation 3

      Inadequate visual inspection qualifications

      OBSERVATION 3 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Employees engaged in visual inspection of sterile finished pharmaceutical products work under (b)(14); however, the qualification of visual inspection the first time the employee is qualified is not performed again at subsequent requalifications. Of the visual inspection staff, (b)(4) were first qualified in (b)(4), (b)(4) were first qualified in (b)(4) with the remainder first qualified more recently, and none were challenged after (b)(4) since their first qualification.

    2. Observation 4

      Incomplete investigations; glass contamination

      OBSERVATION 4 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Investigations into issues requiring the filing of Field Alert Reports are not always complete. For example, 1. Investigation MC-EP1-24-0107 was opened on 06/06/2024 due to a consumer complaint of an 18 mm glass piece found in a dispensed vial of (b)(4) USP (b)(4) mg per (b)(4) ml batch (b)(4). The investigation could not find the source of this glass; however the root cause was attributed to vials breaking in the (b)(4) and leaving glass in intact vials. Corrective actions in the investigation included adding new preventative maintenance to the (b)(4), adding a review of (b)(4) inspection challenge vial for larger glass pieces, and requalification of the visual inspection employees; however, there is no discussion of whether the glass vials used for the product are still acceptable or why the visual inspection was unable to see the glass in the time and conditions of the visual inspection operations, which were changed. 2. Investigation MC-EP1-24-0197 was opened on 10/30/2024 due to a consumer complaint of a 15 mm glass piece found in a dispensed vial of (b)(4) USP (b)(4) mg per (b)(4) ml batch (b)(4). The investigation could not find the source of the glass; however the root cause was attributed to vials breaking in the (b)(4) and leaving glass in intact vials. Corrective actions in the investigation included adding new preventative maintenance to the (b)(4), adding a review of (b)(4) inspection challenge vial for larger glass pieces, and requalification of the visual inspection employees; however, there is no discussion of whether the glass vials used for the product are still acceptable or why the visual inspection was unable to see the glass in the time and conditions of the visual inspection operations, which were not changed. 3. There have been 388 complaints of (b)(4) mg/ml in the last two years, leading to the filing of 57 field alert reports; there have been 231 complaints of (b)(4) USP (b)(4). However, there has been no review of the container closure systems of either product since they were initially marketed to determine if the container closure system was appropriate for the products in light of the complaints and field alert reports.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on May 11, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 27, 2026Not classified yet

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 11, 2026FDA-FOIA-2026-4811Form 483· 1 of 5 sitesRecords released
    2. Apr 7, 2026FDA-FOIA-2026-3449Form 483· 1 of 2 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
EUGIA Pharma Specialities LimitedD-U-N-S 650804896

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names EUGIA Pharma Specialities Limited (D-U-N-S 650804896) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3011960448 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3011960448. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.