Eugia Pharma Specialities Limited Form 483, February 2026

FDA issued this Form 483 to Eugia Pharma Specialities Limited in India (FEI 3011960448) at the end of an inspection that ended February 27, 2026. It lists 4 observations.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Apr 29, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 27, 2026
—
FDA's outcome
Not classified
Not classified yet
Posted by FDA
Apr 29, 2026
61 days after the inspection
Facility
FEI 3011960448
India

The 4 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate aseptic/monitoring controls

    OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, 1. Environmental and personnel monitoring are not appropriately established. The aseptic connection for connecting the (b)(4) vessel for L (b)(4) was performed within the LAF on line (b)(4) July 2025 with bacterial alert and action limits of (b)(4) and (b)(4), respectively. The area is not held to Grade A classification during this critical operation with a specification of No Growth. There is no immediate personnel monitoring conducted for the individual after completing the aseptic connection. 2. The (b)(4) on the sterile filling lines in the (b)(4) installed by the operator (b)(4) Grade A filling area then (b)(4) filling area (b)(4) touch the Grade A exposed portion of the (b)(4) and are not sanitized. 3. The conveyor on Line (b)(4) at the stoppering station is (b)(4). The (b)(4) intervention and entering the area to access the other side of the line resulted in the following deficiencies observed: a. The intervention was not performed according to procedure, which requires that only (b)(4) b. Operations personnel are not personnel monitored after this intervention during filling operations. c. The areas under the (b)(4) were not completely disinfected after reassembly of (b)(4). In addition, Line (b)(4) has a conveyor which is (b)(4). Similar deficiencies were observed with this intervention and Line (b)(4) is qualified up for set-up and filling operations. 4. During the review of CCTV footage for (b)(4) (b)(4) Img/ml Batch (b)(4) observed: a. During the aseptic connection the sterile product transfer line (b)(4) b. Interventions including removal of fallen vials (b)(4) did not ensure that (b)(4).

  2. 2

    No recent media fill validation

    OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, There has been no aseptic process simulation (media fill) conducted since July 2022 for (b)(4). (b)(4) requires (b)(4) using Line (b)(4) connection (b)(4) and is used to perform filling on the filling line. Since March 2024, at least (b)(4) -7 mg/ml have been shipped to the (b)(4).

  3. 3

    Inadequate visual inspection qualifications

    OBSERVATION 3 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Employees engaged in visual inspection of sterile finished pharmaceutical products work under (b)(14); however, the qualification of visual inspection the first time the employee is qualified is not performed again at subsequent requalifications. Of the visual inspection staff, (b)(4) were first qualified in (b)(4), (b)(4) were first qualified in (b)(4) with the remainder first qualified more recently, and none were challenged after (b)(4) since their first qualification.

  4. 4

    Incomplete investigations; glass contamination

    OBSERVATION 4 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Investigations into issues requiring the filing of Field Alert Reports are not always complete. For example, 1. Investigation MC-EP1-24-0107 was opened on 06/06/2024 due to a consumer complaint of an 18 mm glass piece found in a dispensed vial of (b)(4) USP (b)(4) mg per (b)(4) ml batch (b)(4). The investigation could not find the source of this glass; however the root cause was attributed to vials breaking in the (b)(4) and leaving glass in intact vials. Corrective actions in the investigation included adding new preventative maintenance to the (b)(4), adding a review of (b)(4) inspection challenge vial for larger glass pieces, and requalification of the visual inspection employees; however, there is no discussion of whether the glass vials used for the product are still acceptable or why the visual inspection was unable to see the glass in the time and conditions of the visual inspection operations, which were changed. 2. Investigation MC-EP1-24-0197 was opened on 10/30/2024 due to a consumer complaint of a 15 mm glass piece found in a dispensed vial of (b)(4) USP (b)(4) mg per (b)(4) ml batch (b)(4). The investigation could not find the source of the glass; however the root cause was attributed to vials breaking in the (b)(4) and leaving glass in intact vials. Corrective actions in the investigation included adding new preventative maintenance to the (b)(4), adding a review of (b)(4) inspection challenge vial for larger glass pieces, and requalification of the visual inspection employees; however, there is no discussion of whether the glass vials used for the product are still acceptable or why the visual inspection was unable to see the glass in the time and conditions of the visual inspection operations, which were not changed. 3. There have been 388 complaints of (b)(4) mg/ml in the last two years, leading to the filing of 57 field alert reports; there have been 231 complaints of (b)(4) USP (b)(4). However, there has been no review of the container closure systems of either product since they were initially marketed to determine if the container closure system was appropriate for the products in light of the complaints and field alert reports.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.