Skip to content

Eugia Steriles Private Limited

India

FEI 3027357163DUNS 955481156

Company: EUGIA Pharma Specialities Limited · Linked by exact D-U-N-S match (650804896) in FDA registration data

FDA has one inspection on file for Eugia Steriles Private Limited in India (FEI 3027357163). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the five FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, EUGIA Pharma Specialities Limited (D-U-N-S 650804896), has registered 4 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest Oct 1, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Aseptic contamination prevention procedures deficient

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. A (b)(4) trial run was conducted on June 16 - 17, 2026 to simulate the aseptic injection, (b)(4) mg/vial filling and (b)(4) process for (b)(4) and (b)(4) injection (b)(4) mg/vial. The following deficiencies were observed: 1. The vial sampling tray used to conduct manual fill weight verification of (b)(4) filled vials were removed from the Grade A filling area after hand sanitization at approximately 12:03:21 on June 16, 2026, using (b)(4) intervention. The vial sample tray located in the Grade B environment was moved to a (b)(4) then to the sampling weighing station located at (b)(4) (b)(4) and then returned until approximately 14:54:38 (almost 3 hours later). The vial sampling tray comes into direct contact with forceps stationed on the filling line for unplanned interventions of stoppered/unsealed vials. However, there is no detailed cleaning procedure ensuring that each of the (b)(4) in the sample vial tray are adequately sanitized prior to reentry in the Grade A filling line. 2. On June 16, 2026 at approximately 14:25:06 the operator removed his gloved hands from the filling line (b)(4) after unloading (b)(4) stoppers and made direct contact with the Grade B environment. However, he did not sanitize his gloved hands prior to re-entering his gloved hands from the (b)(4) near the (b)(4) into the Grade A environment to directly pulling out the (b)(4) stopper bowl at approximately 14:25:32. 3. On June 17, 2026 at approximately 11:10:50 the (b)(4) leading to the Grade A environment of the (b)(4) Unloading System (b)(4) was unintentionally (b)(4) by the operator after (b)(4). Two operators were in the process of pulling out the (b)(4) separating the Grade A and Grade B environments from beneath the (b)(4). The (b)(4) is used to load and transfer (b)(4) vials to the (b)(4). However, the (b)(4) was not sanitized after being exposed to the Grade B environment. The unplanned intervention was not documented until CCTV review during the current inspection. 4. There is no defined limit on how far above the (b)(4) of the Grade A filling line an operator may extend his gloved hands and within the (b)(4) of the (b)(4) used to store the (b)(4) vials. The (b)(4) was not sanitized after coming into direct contact with sanitized gloved hands from the Grade B environment at approximately 8:51:20 on June 17, 2026. B. On June 10, 2026, the following deficiencies were observed within the Grade A (b)(4) Vial Liquid (b)(4) Product Filling and Stoppering Machine in Line (b)(4): 1. Unsmooth (b)(4) surfaces on the (b)(4) used to store filling tubes during the vial filling process adjacent to the product filling area. 2. Visible scratches on the internal (b)(4) used to cover HEPA filters. 3. Visible gaps between the (b)(4) directly above the product filling area. 4. Peeling tape and proliferated surfaces covering the (b)(4) (b)(4) media plate stands stationed throughout the Grade A environment. 5. Unsmooth and rusted (b)(4) surfaces on the (b)(4). 6. Multiple visible (b)(4) scratches on the (b)(4) of the vial filling line. 7. Multiple visible black and (b)(4) marks/scratches on the (b)(4) empty vial machine. 8. Indented hole and extraneous black material observed on the camera mount surface stationed within the Grade A filling line and above the empty vial (b)(4) machine. In addition, the (b)(4) materials in Laminar Air Flow (LAF) used to stored (b)(4) the Grade B environment was very rusted. C. No dynamic air flow visualization studies have been performed for interventions within the (b)(4) Unloading System (b)(4) used for loading and moving (b)(4) vials prior to (b)(4). This includes the lack of airflow studies for planned interventions, such as changes in environmental monitoring (EM) settle plates and active air sampling plates, which occur approximately (b)(4). In addition there is no en

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate validation of aseptic process

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. Specifically, A. According to the Quality Head, the following (b)(4) sensors, identified as part of the vial (b)(4) process, have not been calibrated or verified: System Component P&ID (Sensor Names) (b)(4) (b)(4) System (b)(4). There is no calibration record for such sensors involving the (b)(4) and (b)(4) built in as part of the stoppering process for (b)(4)-45 and (b)(4)20. In addition, there is no sensor challenge test for the (b)(4) process and sensor locations. According to the Quality Head, (b)(4) stoppering is dependent on (b)(4) being maintained for (b)(4). B. There is no formalized Operation Qualification protocol or report detailing quality unit and production review of (b)(4) alarm events, any challenges, and final outcomes. This includes the lack of detailed review for sensor and alarms used for (b)(4) signals, (b)(4) sensors used as (b)(4) sensors. C. There is no detailed justification by the quality unit as to why planned media fill interventions dictated by the Aseptic Process Simulation (APS) master batch record are not uniformly performed for all (b)(4) campaign batches. For example: (b)(4) (b)(4). In addition, one (1) out of the [illegible] mL media fill vials did not include media fill batches for the following intervention: Intervention No. NI-4-H: Transfer of forceps, forceps holder for (b)(4) (b)(4) side). There is no scientific or written justification as to why Media Fill Batch No. (b)(4) compared to (b)(4). The Quality Manager stated the operator, along with the production supervisor, makes the final determination as to which interventions list in the media fill master batch record will be disregarded (write NA annotation) without any final input decision from the quality unit.

    Show observations 3 to 5
    1. Observation 3

      Quality unit procedures not followed

      The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, A. During my walkthrough on June 10, 2026, I observed that two (2) CCTV cameras were offline. In addition, I observed an outlined circle on the filling machine (b)(4). The Quality Head stated that this was due to future plans to install an additional camera inside the Grade A environment. The firm's CAPA report further states that some of the interventions, which are performed from filling to (b)(4) loading/unloading are not clearly visible from CCTV camera and there is no feasibility of view panel to verify aseptic intervention execution (behaviour and technique). However, activity is now monitored by real time reviewer from aseptic area. Based on the above evaluation, below are the actions to be taken for clear visibility of interventions through CCTV: Room Name and No. Camera Adjustment / New Camera Vial Filling and Stoppering area and (b)(4) New CCTV Camera required at stoppering station (b)(4) CAM-2 Camera angle to be adjusted for better view of Vial Filling and Stoppering area and (b)(4) connections (b)(4) station (b)(4) Loading and Unloading area and (b)(4) New CCTV Camera required at (b)(4) loading shall be relocated to (b)(4) station (b)(4) (b)(4) Loading and Unloading area and CAM-5 (b)(4) (b)(4) CAM-6 Camera angle to be adjusted for better view (b)(4) Loading and Unloading area and (b)(4). For example: At approximately 10:55 am on June 16, 2026, I observed the operator to be adjusting the sensor for the (b)(4) stopper bowl during the (b)(4) trial simulation. However, operator behavior and adjustments are not clearly visible from the CCTV cameras. B. Breakdown report for Line (b)(4) Vial Filling and Stoppering Machine, Equipment ID: PR-VFSMC-002, (b)(4) Injection (b)(4) mg/vial, Batch No. (b)(4) Batch End Date: May 25, 2025, was reported due to Breakdown Description: During filling (b)(4) Alarm occurred. The breakdown maintenance record remained opened during the 2nd batch run, Batch No. (b)(4) (Batch Date: (b)(4) to June 02, 2025) and the troubleshooting: (b)(4) motor occurred on June 01, 2025. However, according to the batch record checklist for review of Batch No. (b)(4) Sr. No 25, Work orders/Maintenance request if any is closed. Result: No. There is no written justification as to why the open work order was not referenced in the batch record. C. There is no standard operating procedure or written justification for the following trials captured in the audit trail for (b)(4) vial liquid (b)(4) product filling and stoppering machine in Line (b)(4) since February 2025: Post Media Fill Trials, Machine Trials, Trials (b)(4) Tube Trial, and Fill Volume Trials. D. There is no equipment logbook in place for the (b)(4) vial liquid (b)(4) product filling and stoppering machine as per SOP EP5-PR-SOP-036-01 Equipment Usage Log, Effective Date: December 21, 2023 requirement. According to the Quality Head, the current electronic e-log has not been synchronized to collect, query and log batch data as originally planned. In addition, there is no manual equipment logbook in place in order for the quality unit to review and verify all Line [illegible].

    2. Observation 4

      Investigations lack conclusions and follow-up

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, A. PNC-EP5-EN-25-0006 was initiated on June 07, 2025 due to power failure for all plant loads and during the (b)(4) process involving (b)(4) mg/vial, batch No. (b)(4). However, the investigation report did not include details surrounding the change in (b)(4) process. In addition, there is no software limitation, internal limit, or study as to how long a (b)(4) cycle can remain interrupted prior to continuation as per MSAT Manager. According to the Quality Head, batch No. (b)(4) was initiated after the power failure incident. However, the batch No. (b)(4) (b)(4) was ultimately rejected due to observed solution leakage from the product transfer line filling area. There was no attempt to repeat the (b)(4) batch thereafter. B. OOS Number ESOOS240002 was initiated for R&D (b)(4) Injection USP (b) mg/Vial, Test: Gross Content by HPLC, Date Initiated: February 03, 2024, Batch No. (b)(4) Results: (b)(4) mg/vial (Specification Limit: NLT (b)(4) and NMT (b)(4)). The manufacturing investigation attributed the most probable root cause to potential issues with connections to vessels during (b)(4) calibration that may not have been accounted for during manufacturing final volume make-up. Additionally, (b)(4) during calibration present in the vessel (b)(4) may have been drained prior to final volume make-up. The operator stated that he likely forgot to add the vessel lid for (b)(4) of the batch during the compounding stage. However, the investigation [illegible] (b) mg vial batches in the same campaign to see if there were any similar (b)(4) and (b)(4) mg are (b)(4) manufactured in campaigns in order to maximize the usage of (b)(4) e.g. reduced (b)(4) (b)(4) and cleaning time). Product Name Type Product Size Start Date End Date of Batch No. Batch Market (b)(4) (b)(4) 13/01/2024 USA/EU 16/01/2024 USA/EU 21/01/2024 USA/EU 24/01/2024 USA/EU 27/01/2024 USA/EU 29/01/2024 USA/EU. In addition, CAPA-EP5-PR-24-0029-OA-0003 was opened on May 27, 2024, to extend the investigation to identify the exact root cause for gross content failure. However, a trial run for Line (b)(4) was conducted to [illegible] pumps with (b)(4) pumps instead. Issues concerning the filling line machine pumps was not documented as part of the initial investigation root cause analysis. In addition, there was no hypothesis testing or scientific justification documented to support the need to replace the material of construction with for the (b)(4) mg and (b)(4) mg vial filling pumps.

    3. Observation 5

      Test method reproducibility not established

      The reproducibility of test methods have not been established. Specifically, (b)(4) Injection, (b)(4) mg/ml) analytical methods and process was directly transferred from the (b)(4). However, the analytical methods were [illegible]. laboratory came on-site to conduct testing of the homogeneous sample along with an analyst from the receiving laboratory. However, there was no verification or review of the external and operational variables between both sending and receiving sites, including differences in environmental conditions and instrument models.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Oct 1, 2026. Each one asked for a Form 483.

  • Inspection ending Jun 19, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Oct 1, 2026FDA-FOIA-2026-9541Form 483Records released
  • Inspection ending Feb 18, 2025

    4 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 + EIR on Dec 18, 2025. FDAgent holds no copy that FDA posted.

    1. Dec 1, 2025FDA-FOIA-2025-13391Form 483 + EIRRecords released
    2. Jul 24, 2025FDA-FOIA-2025-9088Form 483· 1 of 3 sitesClosed
    3. Jun 18, 2025FDA-FOIA-2025-7775Form 483· 1 of 10 sitesWithdrawn
    4. Feb 20, 2025FDA-FOIA-2025-1618Form 483· 1 of 2 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
EUGIA Pharma Specialities LimitedD-U-N-S 650804896

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names EUGIA Pharma Specialities Limited (D-U-N-S 650804896) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3027357163 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3027357163. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.