Torrent Pharmaceuticals Limited
Ahmedabad Mehsana Highway,Taluka-Kadi, Dist. Mehsana, Indrad, India
FEI 3005029956DUNS 916488547
Company: Torrent Pharma, Inc. · Linked by exact D-U-N-S match (790033935) in FDA registration data
FDA has 7 inspections on file for Torrent Pharmaceuticals Limited in Indrad, India (FEI 3005029956), from 2013 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Sep 28, 2022. FDA issued a warning letter on (CDER). 11 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Torrent Pharma, Inc. (D-U-N-S 790033935), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 7, 2013–2024
- 2 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 7
- Requested under FOIA
- 3 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- 11 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Stability testing and OOT handling
OBSERVATION 1 There is no testing program designed to assess the stability characteristic of drug products. Specifically, Your Quality Unit failed to ensure the drug products sold into the [illegible] shelf life. A. Your batches of [illegible] full products had confirmed/valid out of trend (OOT) results but were released by [illegible] distributed into the market from October-2022 to May-2024. This was in deviation of your Quality Unit's responsibilities towards batch disposition per procedure CQA-070-06, titled: "Procedure for Investigation Out of Trend (OOT) Results in Drug Product Manufacturing", effective date: 06-Apr-2023, Attachment-I 'FlowChart...E.01 OOT Investigation', which states test results concluded as confirmed/valid OOT upon [illegible] and manufacturing investigation required "Batch disposition by QA". The evaluation trend of batches at release for years 2022 and 2023 revealed that total 70 valid OOT batches were distributed into the market of which about 34 batches were reported [illegible] Dissolution by HPLC and 1 for Organic Impurities by HPLC and 1 batch for Content Uniformity. None of these valid OOT batches were charged on stability. Further, many of the annual stability batches were also observed to have valid (25°C/60%RH), but your Quality Unit continued to remain [illegible]. (b)(4). The evaluation of historical stability trend of your drug products revealed the potential for the assay of drug products to decrease during the product shelf life (b)(4) as a result of the potential for the product to transition from valid OOT. Heins.o.ection on 11-Jun-2024 your firm filed Field (b)(4). Alternatively, stability trends have also shown unexpected increases, for example: (b)(4) which showed a +4% Assay from (b)(4) to (b)(4); (b)(4) which showed a +4% Assay; (b)(4) which showed a +4% Assay; (b)(4) which showed a +4.3% Assay; (b)(4) which showed a +2.6% Assay from (b)(4). Per your Quality Unit these increases in the Assay test results have remained unknown for (b)(4). Whereas for (b)(4) tablets it was attributed to issues (b)(4). No. (b)(4) (version: 10) for which the firm has not initiated [illegible]. Evaluation of email communications revealed that your Quality Unit, per the email dated 17-Dec-2022, they initiated a series of [illegible]; there has been no progress made for over approximately [illegible] revalidation of the analytical test method and to evaluate the root cause. Your firm continued to keep manufacturing and releasing (b)(4) Tablets batches into the US market using [illegible] understood and potentially giving unreliable Assay test results. The variations in the assay test results are reflective of the potential for the OOT batches to be true OOS and increase the risk for subpotent products within the market. The evaluation of the Adverse Drug Events (ADEs) received multiple market complaints relating to lack [illegible]. These complaints were not logged in at your site and investigated as Product Quality Complaints (PQCs). C. Your OOT investigations are deficiently conducted in that the evaluation performed only on the expired batches. There was no monitoring of ongoing stability batches that were also resulting into the OOT valid test results. D. Your procedure for OOT investigations (SOP No.: CQA-070-06) is deficient. Per this procedure, there are no requirements to take any market action if a valid OOT stability batch that is commercialized into the US market [illegible] other batches manufactured in that year.
- Observation 2
Inadequate OOS investigation and review
OBSERVATION 2 (Repeat Observation from September 2022) There is a failure to thoroughly review any unexplained discrepancy and the failure to [illegible] components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. OOS Number: OOS/B/ST/22/084, Date of Event: 09-Dec-2022, Product: (b)(4) tablets (b)(4) count bottles), Batch Type: (b)(4) batch, time point: 3 Month, 25°C/60%RH, Issue: OOS found. (b)(4) result documented as (b)(6) against as specification. On Jan-2023, the batch had expiry of (b)(4). OOS was found for (b)(4) count bottles whereas the (b)(4) count bottle is marketed in the US. However, the same bulk batch number (b)(4) tablets was used to package the different finished bottles. Process Validation represented (b)(4) commercial batches [illegible] drug product manufactured until (b)(4) that are sold into [illegible]. Your OOS Investigation procedure CQA-057-06, Titled: Procedure for Investigation of Out of Specification Results (OOS), Effective date: 06-Apr-2024 is deficient to define handling of OOS investigation along with responsibilities of QA for recall(s).
Show observation 3
- Observation 3
Inadequate equipment cleaning and oversight
OBSERVATION 3 (Repeat Observation from Sep) Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that could alter the safety, identity, strength, quality or purity. Your (b)(4) cleaning procedure for non-dedicated manufacturing equipment cleaning is inadequate in that it does not ensure the removal of (b)(4) products to avoid potential cross-contamination. For example, On 03-Jun-2024, I observed large deposition of (b)(4) inside the (b)(4) product non-contact areas (b)(4). This (b)(4) equipment is used to manufacture (b)(4) products for (b)(4) markets. This equipment was cleaned through (b)(4) (firm conducted a protocol GS/IN/TAB/QMS/2024/01 (b)(4) materials on (b)(4) and tested sample by HPLC. The evaluation revealed (b)(4) previous product) in the (b)(4). B. Your Quality Unit lacked adequate oversight on the review and evaluation of Equipment Cleaning Records (ECRs). For example, 1. The column pertaining to "Issue Quality..." (b)(4) equipment cleaning records pertaining to (b)(4) issued by, verified by, and checked by sections on 23-Feb (b)(4) unit on 13-Mar-2024. Your firm uses (b)(4) w/w of (b)(4). The review of "PREPARATION USAGE AND (b)(4)" (b)(4) revealed that (b)(4) or the (b)(4) (b)(4) preparation detail was signed under prepared by and checked by sections dated 14-Apr-2024.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to thoroughly review OOS discrepancies
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, The summary of OOS investigations conducted by the firm during the period beginning from January 2017 to March 2019 is as follows: 2017 to 2019 Valid Invalid % Invalid Finished Product 340* 93 247 73% Stability 203* 80 123 61% *excludes on-going investigations at the time of inspection Review of the firm's OOS investigation revealed that the firm's investigation practices and procedure(s) are deficient. Several examples were found where the original failing results were invalidated without a scientifically sound and justifiable root cause, and results of passing re-test results were reported as the result of record. Examples include, but are not limited to, the following OOS investigations: (A) OOS Investigation Number OOS/IN/F/FP/17/233 for (b)(4) and (b)(4) Tablets (b) mg/(b) mg pertaining to batch number (b)(4) was initiated on 07/01/17 to probe the following OOS results generated during (b)(4) testing for Assay: (b)(4) Mean RSD% (b)(4) 102.8 5.57 (b)(4) 97.3 1.74 Specification* Mean: (b)(4) to (b)(4)% of label amount Individual: (b) to (b)% /(4) /(4) *as in the OOS report The OOS results were confirmed during preliminary investigation and hypothesis testing (Phase I) with no identified root cause. No manufacturing error was identified during Phase II investigation. The initial OOS results were invalidated based on reserve sample testing of set (b)(4) sample sets. The higher Assay results were invalidated without identifying a definitive root cause. The manufacturing process of this product consists of a (b)(4) process. The investigation could not conclusively identify if there is any laboratory error or manufacturing error and no CAPA was initiated. The (b)(4) was released using re-tested reserve sample set results. (b)(4) was released to U.S. market with an expiry date of (b)(4). In addition, the documents provided to the investigators in support of OOS Investigation Number OOS/IN/F/FP/17/233 included an unsigned OOS Amendment Report. This document had a print date of 8/27/2018. (B) OOS Investigation Number OOS/IN/F/FP/17/238 for (b)(4) and (b)(4) Tablets (b) mg/(b)(4) mg pertaining to batch number (b)(4) was initiated on 7/4/17 to probe the following OOS results generated during (b)(4) testing for Assay: (b)(4) Mean RSD% (b)(4) 100.7 2.13 (b)(4) 103.7 9.24 Specification* Mean: (b)(4) to (b)(4)% of Label Claim Individual: (b)(4) to (b)(4)% *as in the OOS report The OOS results were confirmed during preliminary investigation and hypothesis testing (Phase I) with no identified root cause. No manufacturing error was identified during Phase II investigation. The initial OOS results were invalidated based on reserve sample testing of set (b)(4) sample sets. The higher Assay results were invalidated without identifying a definitive root cause. The manufacturing process of this product consists of a (b)(4) process. The investigation could not conclusively identify if there is any laboratory error or manufacturing error and no CAPA was initiated. The (b)(4) was released using re-tested reserve sample set results. (b)(4) was released to the U.S. market with an expiry date of (b)(4). (C) The same deficient investigative process as in (A) and (B) above was followed to probe (b)(4) Assay failure in OOS/IN/F/FP/18/070 for (b)(4) and (b)(4) Tablets (b)(4) mg/(b)(4) mg tablets pertaining to batch number (b)(4) (Expires (b)(4)). No definitive root cause was identified. (D) OOS Investigation Number OOS/IN/F/FP/17/340 for (b)(4) Capsules USP (b)(4) mg for PV batch number (b)(4) was initiated on 11/06/17 to probe the failing (b)(4) result as follows: (b)(4) Mean RSD% (b)(4)(%) 97.4 1.07 Sample Wt. (mg). Specification NLT (b)(4)% and NMT (b)(4)% of Label Claim, RSD NMT (b)(4)% The OOS results were confirmed during prelimin
Shortened here; the PDF has the full text.
- Observation 2
No written production process control procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, Review of Process Validation (PV) documents revealed that PV batches that failed process validation protocol requirements and quality attributes were deemed acceptable and counted towards successful manufacturing process validation. For example, Process Validation for (b)(4) Tablets USP (b)(4) mg, and (b)(4) Tablets USP (b)(4) mg for qualifying an alternate API code (#(b)(4)) is deficient. All process validation batches were rejected as summarized below: Strength (b)(4) mg (b)(4) mg Total PV batches 4 3 Total OOS investigations 6 3 Batch Disposition All rejected All rejected (A) Process Validation for (b)(4) Tablets USP (b)(4) mg The following OOS investigations were initiated during testing of process validation batches: OOS No. OOS/IN/F/FP/16/257 OOS/IN/F/FP/16/137 Date of Initiation 9/29/16 7/23/16 Batch #(b)(4) PV Number 1 1 1 Test Results F2 = (b)(4) Assay = (b)(4)% (b)(4)*(min) = (b)(4)% Specification F2 NLT (b)(4) (b)(4)-(b)(4)% OOS/IN/F/FP/16/263 10/4/16 (b)(4) 1 (b)(4)% NMT (b)(4)% (b)(4) (b)(4) Due to the failures, an additional PV batch (#4) was added to the validation campaign. However, the 4th batch failed for F2 dissolution similarity factor as follows: OOS No. Date of Initiation Batch # PV Number Test Results F2 Specification OOS/IN/F/FP/17/139 4/10/17 (b)(4) 4 F2 = (b)(4) F2 NLT (b)(4) OOS/IN/F/FP/17/143 4/10/17 4 F2 = (b)(4) F2 NLT (b)(4) PV batches (b)(4) (PV# 1) and (b)(4) (PV# 4) were rejected and destroyed leading to only 2 successful process validation batches. The firm's quality unit also rejected the remaining 2 batches. Despite the PV batch failures and rejections, the process validation for the alternate API vendor was deemed successful per interim validation report # PVR/BTL.508.01-33E/18, approved on 01/17/18. (B) Process Validation for (b)(4) Tablets USP (b)(4) mg The process validation initiated to qualify an alternate API supplier (#(b)(4)) for (b)(4) Tablets USP (b)(4) mg is deficient. Three process validation batches were rejected and destroyed based on OOS investigations for (b)(4) failures. However, despite the critical attribute (i.e. (b)(4) failures), the manufacturing process utilizing the alternate API supplier was still considered valid and acceptable by the Quality Unit. The process validation report # PVR/BTL.510.01-40E/18, approved on 01/05/18 stated that during further review, the route of synthesis for the old API code ((b)(4)) and the new API code ((b)(4)) are only marginally different and would not impact the quality of the finished product. In both cases (A) and (B) above, the respective process validation report states the following: Due to change in API there is no impact on manufacturing process & no impact of API quality on finished goods So API code (b)(4) shall be used for commercial and it is recommended to abort validation for further commercial batches in SFG code: (b)(4) and regular commercial batches shall be manufactured with same parameter which are available of SFG code (b)(4) as there is no change in process parameter. The batch disposition status for the (b)(4) mg and (b)(4) mg batches manufactured and released to U.S. market with alternate API code (b)(4) is as follows. Product Batch status Count (b)(4) Tab, USP (b) mg Hold 3 Rejected 5 Released (b)(4) (b)(4) Tab, USP (b) mg Hold 4 Rejected 3 Released (b)(4) Grand Total (C) Process Validation for Lamotrigine ER Tablets 200 mg The process validation for Lamotrigine ER Tablets 200 mg is deficient. The pre-validation risk assessment to determine the number of batches required to successfully demonstrate process validation is not scientifically sound. For example, the risk assessment detailed in the process validation protocol (PV/BTL.524.01-5E/17/01-01, approved on 11/04/17) considered the functional co
Shortened here; the PDF has the full text.
Show observations 3 to 4
- Observation 3
Routine calibration of automatic equipment deficient
Routine calibration of automatic and electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, The qualification of Tablet (b)(4) machine (equipment ID# (b)(4)-03) is deficient. This equipment is proposed for the commercial manufacturing of (b)(4) tablets ((b)(4) and (b) mg) for (b)(4) #(b)(4) and (b)(4) Tablets ((b)(4) and (b) mg) for (b)(4) #(b)(4). The following issues were observed during the inspection: Per equipment (b)(4)-03 maintenance manual, the required calibration includes the (b)(4) and the (b)(4) USB interface. These parameters are critical for the quality of the tablet (b)(4) process. The general manager of Engineering department provided the current equipment calibration certificate for equipment (b)(4)-03 with Certificate number TPL/T/0196/01/19. This certificate did not include the two required calibration items. The last calibration provided by the equipment manufacturer expired in January 2019. Additionally, the production operators purportedly trained on the operational aspects of (b)(4)-03 confirmed that they do not know how to set up the vision profile settings for the vision inspection system on the machine. The vision system ensures that the (b)(4) tablets conform to in-process specification limits. A service engineer representative also confirmed that he is unaware of how to correctly setup the vision inspection system. Consequently, during the (b)(4) process demonstration on 04/12/19, several false rejects were found in the reject chute associated with the vision check cameras on the equipment thus providing no assurance of the optimum functionality of the vision system.
- Observation 4
API out-of-specification investigation deficient
Out of Specification Investigation for API products is deficient. Specifically, OOS Investigation Number OOS/IN/A/ST/17/013 for (b)(4) pertaining to batch number (b)(4), was initiated on 03/06/17 to probe the following OOS results generated during Assay testing at the 12M time point (25°C/60%RH and 30°C/75%RH): 25°C/60%RH: (b)(4)% 30°C/75%RH: % Note: Specification is NLT (b)% and NMT (b)(4)% (on Anhydrous basis) As part of hypothesis (Phase I), a re-dilution study was not considered using the diluent allowed by the method to rule out any dilution error. Additionally, a service engineer for the instrument confirmed that there was no instrument failure during initial or hypothesis testing. However, instrument error was still suspected and substantiated by intentionally pumping air bubble into the system and the standard injections yielded results higher than the specification limits. Furthermore, since the method validation for solution stability was deficiently established only for (b)(4), a second set of samples was analyzed in duplicate to invalidate the original failing results. Passing results from initial sequence for other batches were also discarded, and re-tested results were reported without a valid justification. No consideration was given to report the average of all passing results when a definitive root cause is not identified.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit procedures not fully followed
The responsibilities and procedures applicable to the quality unit are not fully followed. Specifically, 1. The following deficiencies were noted with the change control program: a. Change control records were not closed in a timely manner. Section 4.0 of SOP CQA-055, Version 4.0, Change Control Management Across all the Locations, effective date 1 DEC 16 states that it is the responsibility of the Head of Quality to complete a 'Periodic review of status of Change control forms for its implementation'. However, according to the Review of Change Control Form for the year 2016, Quarter 4 (Document no. CCFS/INF/16/Q4 approved on 7 FEB 17): Year 2011 2012 2013 2014 Number of Change Control Records that Remain Open 3 65 168 226 No final action has been taken for the changes that have not been implemented, and a final assessment has not been made for those changes that have been implemented. b. A Change Control record was not initiated per SOP CQA-055, Version 4.0, Change Control Management Across all the Locations, effective date 1 December, 2016. The Stability Study Data Sheet, RLT/3476/01, effective date 3 June 2016, for the Dissolution Testing of (b) (4) Tablets (b) (4) (b) (4) mg) was updated to include instructions to ensure that the pH meter is calibrated with buffers at pH (b) (4) and (b) (4) immediately before adjusting the pH of the dissolution media. 2. Batch Record Review by Quality Assurance (QA) was deficient: a. The production batch record for (b) (4) Stage (b) (4) Batch (b) (4) had (b) (4) weights recorded for the standard preparation and (b) (4) weights recorded for the sample preparation. There were (b) (4) printouts for weight, and the two printouts dated 16 OCT 16 were stamped with the word 'DISREGARD'. There was no indication or reference recorded in the batch record stating why these weights were disregarded, why the printouts for the weights dated 18 OCT 16 were accepted, or why the incorrect weights on the previous page were not crossed out. The batch record was reviewed and approved by QA on 20 OCT 16, but this discrepancy was not noted or corrected. b. The production batch record for (b) (4) Finished API batch (b) (4) was missing a page. This discrepancy was noted during production and a deviation was raised. The operator recorded the results on the back of page 44 of the issued batch record. This page was not signed as reviewed or verified by QA. 3. Validation batches that fail to meet specification are subsequently not considered to be validation batches without a justification. For example, Validation Protocol PV/BTD.77.05-4E/15 stated that three consecutive validation batches of (b) (4) were manufactured. However, Validation Report PVR/BTD.77.05-4E/16 only included data from two batches (b) (4) and (b) (4)) and did not evaluate batch (b) (4) which failed to meet specification. 4. Poor documentation practices were observed such as the failure to include details such as product name, product strength, nature of the problem, or summary of the conclusion of the investigation in deviation investigation records and change control records such as CCF/INF/16/0352 and CCF/INF/15/0533.
- Observation 2
Failure to thoroughly investigate discrepancies
There is a failure to thoroughly investigate discrepancies whether or not the batch has been distributed. Specifically, Investigation OOS/IN/A/FP/15/019 dated 10 OCT 15 reported out-of-specification (OOS) results for description for (b) (4) Stage (b) (4) batches (b) (4) and (b) (4). A (b) (4) color was observed. Investigation OOS/IN/A/FP/15/023 dated 7 NOV 15 reported OOS results for description for (b) (4) Stage (b) (4) batches (b) (4), (b) (4) and (b) (4) reported as (b) (4), (b) (4), and (b) (4). The specification for description of (b) (4) Stage (b) (4) was originally (b) (4) to (b) (4). (b) (4) (b) (4) Stage (b) (4) is an intermediate in the production of (b) (4) finished API. (b) (4) Stage (b) (4) material is (b) (4) in nature and is (b) (4). This intermediate product is packaged and sampled (b) (4). The investigation into the observed color changes concluded that the presumptive root cause was exposure to moisture during handling. However, it has not been determined whether: (i) the color change impacts material on the surface, or if the entire batch is affected, and (ii) whether moisture can cause a color change to (b) (4) (b) (4) or (b) (4). Furthermore, there is no color standard for analysts to use for comparison during analysis. Further, per CCF/TRC/15/1649, dated 20 NOV 15, the specification for description was changed to (b) (4) to (b) (4) color powder'.
Show observations 3 to 4
- Observation 3
Lab equipment used outside calibrated range
Laboratory equipment used for analytical testing was used outside of the calibrated range. Specifically, the HPLCs, GCs and dissolution units located in the API, formulation (finished dosage form) and stability sample quality control testing laboratories were used outside of the calibrated range. For example: a. SOP No.: IPQC-124-02, Annexure VIII, titled "Wavelength Accuracy Check" states that wavelength accuracy for HPLCs should be calibrated at (b) (4) +/- (b) (4) nm. However, according to test method STP No. CTP/1405, Version 00, a wavelength of (b) (4) nm is used to detect degradation products of (b) (4) (b) (4) by HPLC for the (b) (4) and (b) (4) tablets (b) (4) mg, (b) (4) mg - batch (b) (4) using HPLC 1112 located in the Stability Laboratory. b. An unqualified thermocouple (Identification No. TH/1285, Serial No. 32400093WS) was used for the verification of GC column oven temperature (eg. GC-1050 located in formulation laboratory and GC-1882 located at API laboratory). This thermocouple was certified for measurements between 50C to 450C. However, according to SOP IPQC-136-03, titled "Procedure for operation, cleaning and calibration of Gas Chromatograph with head space"; the column oven temperature of the GC should be verified and adjusted with the aid of a calibrated thermocouple at the temperature points of (b) (4) and (b) (4) C. A temperature of (b) (4) C is outside of the certified working range of the thermocouple. c. According to the SOP: CQA-078, Version 03 titled, "Procedure for analysis, reporting and reviewing of analytical data", a (b) (4) working standard solution should be injected after a set of (b) (4) or (b) (4) dissolution samples for quantitative analyses. No (b) (4) working standard solution was used for dissolution tests conducted at the API, formulation (finished dosage form) and stability sample testing laboratory (eg. Dissolution unit: DI/1265 located in formulation laboratory and DI/456 located in stability laboratory).
- Observation 4
No check standard for chromatographic testing
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, during the establishment of system suitability for chromatographic analyses, the firm did not prepare or use a second working standard solution (Check Standard Solution) to confirm the potency, accuracy and purity of the working standard solutions (Primary Standard Solution). A single standard preparation was used to determine the potency, accuracy and purity of the active pharmaceutical ingredient in the sample solution. For example: for the assay, content uniformity, and degradation product tests of (b) (4) & (b) (4) Tablets ((b) (4) mg/(b) (4) mg) recorded in Analytical Report No. 040000203053, a Check Standard was not used. For the assay, content uniformity, and degradation product tests of (b) (4) & (b) (4) Tablets ((b) (4) mg/(b) (4) mg) recorded in Analytical Report No. 040000203966, a Check Standard was not used.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test methods
The specificity of test methods have not been established and documented.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Jun 12, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 13, 2024FDA-FOIA-2024-5139Form 483Closed
Inspection date not given
2 requests.
- FY2023FDA-FOIA-2022-7039Form 483Closed
- Apr 26, 2019FDA-FOIA-2019-3588Form 483Open
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3005029956, one row per refused product line.
11 refusals from 2017-05-25 to 2026-05-15 · charged UNAPPROVED on 11, NOT LISTED on 1 · no FDA sample analysis
FDA firm profile- 2026-05-15
NIFEDIPINE (VASODILATOR)66SCA27
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-8099523-5/10002/1
- 2025-10-09
ESOMEPRAZOLE MAGNESIUM (ANTI-SECRETORY)62TCC06
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7693530-1/30003/1
- 2023-10-27
LISINOPRIL (ANTI-HYPERTENSIVE - PART II)62ODY40
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7577854-9/11/2
- 2023-06-06
ESOMEPRAZOLE MAGNESIUM (ANTI-SECRETORY)62TDF06
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-4970688-1/11/2
- 2021-08-26
DOMPERIDONE61TCA31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-6981809-6/71/2
Show 6 more
- 2021-08-09
CLOPIDOGREL BISULFATE (ANTI-COAGULANT)61LDA38
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-6732149-9/11/3
- 2020-10-21
DOMPERIDONE61TCA31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-2641409-6/11/7
- 2020-03-20
DOMPERIDONE61TCY31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-9081010-3/11/2
- 2018-04-30
DOMPERIDONE61TCY31
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4456855-5/71/1
- 2018-04-30
ACYCLOVIR (ANTI-VIRAL)62VCY18
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-4456855-5/61/1
- 2017-05-25
MISCELLANEOUS PATENT MEDICINES, ETC.66VDA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-0666375-9/11/4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Torrent Pharma, Inc.D-U-N-S 790033935
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Torrent Pharma, Inc. (D-U-N-S 790033935) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Torrent Pharmaceuticals LimitedGandhinagar, India · FEI 30127403151 inspection1latestApr 10, 2026NAINone on file
- Torrent Pharmaceuticals LimitedBharuch, India · FEI 30102282355 inspections5latestJan 23, 2026NAINone on file
- Torrent Pharmaceuticals LimitedVisakhapatnam, India · FEI 30067632615 inspections5latestAug 1, 2025NAINone on file
- Torrent Pharmaceuticals LimitedPithampur, India · FEI 30088615874 inspections4latestOct 18, 2019VAINone on file
Other FEIs recorded as Torrent Pharmaceuticals Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Torrent Pharmaceuticals LimitedFEI 3007078804Gandhi Nagar, India
Last inspected 2024-10-04NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3005029956 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3005029956. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.