Skip to content

Dr. Reddy's Laboratories Form 483, February 2017

FDA issued this Form 483 to Dr. Reddy's Laboratories in Nalgonda, India (FEI 3005447965) at the end of a drug inspection that ended February 21, 2017. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Feb 21, 2017. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 21, 2017
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Feb 21, 2017
0 days after the inspection
Facility
FEI 3005447965
Nalgonda, India

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Test method specificity not established

    The specificity of test methods has not been established. Specifically, A. Your firm failed to perform the stress (forced degradation) studies for the ®® USP non-compendia optical purity test by HPLC analytical test method during the test method validation. The validation number 20 EAiVIVA 002, dated 06/26/2002 does not contain the specificity/selectivity studies necessary to demonstrate the suitability and adequacy of the analytical test method and specifications, S-08-®@-USP/13, used for the release and stability testing of this Active Pharmaceutical Ingredient (API). In addition, the current HPLC chromatographic purity test profile was found different than that obtained during the method validation. The retention time for [illegible] peak changed from about [illegible] minutes in the validation to [illegible] minutes during the routine testing. B. The data supporting validation activities performed by your firm to demonstrate the suitability and adequacy of the analytical method used for the release and stability testing of ®® USP Active Pharmaceutical Ingredient (APT) was found to be inadequate and incomplete. Data and documents presented by your firm supporting the validations number: 20-®® AVR-001-10 for the non-compendia Related Substances analytical [illegible] test method and specification, S-08-®@_USP/07, does not contain the specificity/selectivity studies necessary to determine if the method is a stability indicating method for the testing of the API. Validation documents showed that the validation of the methods does not contain complete forced degradation studies. Degradation of the main peak was not achieved. In addition, the routine analytical test method specification, S-08-®@_USP/07, failed to contain the precision standard system suitability (%RSD) that [illegible] the injection of the sample solution. Nevertheless, the validation of the test methods were approved by QCU.

  2. 2

    Instrument calibration deficiencies

    Procedures describing the calibration of instruments are deficiently written or followed. Specifically, a) The calibration of the Gas Chromatographic (GC) instruments was incomplete. The review of the ®@ Operational Calibration for the Agilent GC/Headspace (GC/HS) QC-206, conducted by the outside contractor and as in-house calibration, did not include the HS oven temperature, noise and drift, signal to noise and detector accuracy tests as part of the GC/HS calibration. The GC instruments were used for the Residual Solvents test determination for release of the APIs and raw materials. b) The micro balance, QC-465, was used outside its calibration range (usage range: 10 mg to 2 g) for the testing of ®@ USP Active Pharmaceutical Ingredient (API) during release and stability studies. The firm performed and documented the weight of [illegible] mg, [illegible] mg, [illegible] mg, [illegible] mg and [illegible] mg for the standards of the related substance test for ®® USP, batch number [illegible] using the balance number QC-465 that was certified for weights in the range of 10 mg to 2 g. In addition, the linearity of this balance was performed with three points starting with 10 mg and the accuracy with 10 mg that do not support the use of the balance below 10 mg.

  3. 3

    Unvalidated USP method modifications

    Records maintained of any modification of an established method employed in testing do not include the reason for the modification, the data to verify that the modification produced results that are at least as accurate and reliable for the material being tested as the established method. Specifically, Your firm failed to follow the USP monograph identification test method for the Ultraviolet Absorption <197U> that defined how to perform the test and calculate the results for ®® API's. For [illegible] it was noted that the absorbance readings were obtained at a maximum wavelength other than [illegible] nm as prescribed by the USP test monograph. During the review of ®® batches [illegible] it was observed that the absorbance was determined at approximately [illegible] nm instead of the exact wavelength of [illegible] nm as established by the USP test monograph. Also, the final calculations were performed with the absorbance readings instead of absorptivity as prescribed by the USP monograph. These modifications to the USP test method and calculation formulas were not validated or the equivalencies demonstrated.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3005447965, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.