Sun Pharmaceutical Industries Limited
Unit 1 Plot A-41, Sez Industrial Area, Phase Viii A, Mohali, India
FEI 3002807979DUNS 650456002
Company: Sun Pharmaceutical Industries Limited · Linked by exact D-U-N-S match (650172430) in FDA registration data
FDA has 7 inspections on file for Sun Pharmaceutical Industries Limited in Mohali, India (FEI 3002807979), from 2011 to 2022. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Sun Pharmaceutical Industries Limited (D-U-N-S 650172430), has registered 9 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2011–2022
- 2 OAI · 3 VAI · 2 NAI
- Inspections with 483 observations shown
- 2 of 7
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Written Procedures Not Followed
Written procedures are not followed for the testing of components.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
Following/documenting laboratory controls
Established sampling plans, test procedures and laboratory control mechanisms are not documented at the time of performance.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Show 1 more citation
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
OOS investigations; IR analyst training deficiency
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, a. Tablets @mg, written OOS investigation #217272, was opened on 22 April 2016 and closed on 06 June 2016 for related substance test of of © The failing result obtained on 20 April 2016 for batch # OO%as © % with specification of NMT ” “%. Three additional batches were associated with the investigation batches # RL: © Oand # © Oyith falling results of Oy, © and PN ( of) respectively. The laboratory investigation revealed no laboratory error after sample re-analysis. A full investigation was done in production and a non-assignable cause was identified. The batches associated with the event were released to the market in the month of March 2016. The impurity specification of CONMT® “yy for finished dosage form was changed in line with the EP pharmacopeia specification @ “hy tor © AP] after these OOS results were obtained to justify the release of the ©@Tablet batches. Additionally, the firm's did not follow SOP #OP013156, entitled, Handling of Out of Specification Results (OOS) which requires the batch disposition of rejected if the OOS result was found valid. b. Tablets omg and (mg, written OOS investigation #221781, was opened on 28 May 2016 and closed on 07 June 2016 for IR test identification. The investigation was regarding the analyses of batches rel HQ #9 #0 HR Go and © performed on 23 May 2016 that did not comply with the wavenumbers ©“+ {5 “+” and ®“+ © On 10 November 2016, during the laboratory tour I interviewed the analyst who performed the IR identification analyses (* ®) and he stated that he performed the IR identity test without being trained in the IR identification of the finished product test of © ®iablets. The firm failed to train and qualify the analyst in the IR identification of Tablets prior to assigning finished product samples to be analyzed by IR.
- Observation 2
Incomplete laboratory repeat-testing records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, There is a failure to document repeat testing in the laboratory equipment logbook when samples are reanalyzed from the same sample preparation vial. On October 29, 2016, raw material batch (BX was tested twice for “and © “Bement via Atomic Absorption Spectrometry (AAS) due to invalidated runs. However, the AAS equipment logbook does not show that repeat analysis was performed. In addition on April 27, 2016, © @patch © “uvas tested for “content via AAS three times due to invalidated runs but the equipment logbook only shows that the batch was tested twice.
Show observations 3 to 7
- Observation 3
No password protection on lab balance
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, There is no password protection for the Sartorius GP3202 precision balance instrument ID MQABAL04 that is used in the quality control testing laboratory to weigh for analysis. Laboratory analysts have the ability to change instrument settings including date and time on the instrument.
- Observation 4
In-process testing and specifications lacking
Examination and testing of samples is not done to assure that in-process materials conform to specifications. Specifically, Raw material used by your firm for manufacturing of “ng and @mg tablets, is reprocessed and in manufacturing operations. Your firm keeps as "7g specification solely for testing of" However, the®® “ specification is pe to that of the incoming aw material. There is no fugtification for the use of a” test for the ©“ or the®*® range listed in the » specification. While V.Y., Regional Quality Head claims the ®® or "processing of © “is used to improve tablet range, there is no data showing direct correlation between OE and finished tablet
- Observation 5
QC lacks review authority over production systems
The quality control unit lacks authority to review production records to assure that no errors have occurred. Specifically, SOP OPO13152 "Good Documentation Practices (GDP)" effective date July 28, 2016 explains that Quality Assurance is to periodically review electronic data as a part of self-inspection. However, periodic review of electronic data is only being performed for the quality control testing laboratory and is not being is not performed for the programmable logic controller (PLC) and automated systems located in the production area. Regarding this, a. Quality assurance does not periodically review the alarms generated in the automated systems and the only automated equipment alarms that are being reviewed are the ones that production operators document in the batch production records that cause an equipment stoppage during a production run. b. Event logs (audit trails) generated in the human machine interface automated compression machine are not periodically reviewed by quality assurance for disassembly, cleaning, change over and preventative maintenance. Quality assurance only reviews the hard copy printout event logs printed by production personnel and attached in the batch production record after the completion of a compression batch that document the activities performed between the start and stop of a production run. c. On November 9, 2016, during a walk-through of the production area, we observed an error message prompt on the human machine interface automated compression machine equipment ID MPDRCMO1 that read the following: "valid"? is required". According to production operators in the area, the error message has been appearing for months on the equipment. However, quality assurance was not notified of the error message prompt on the machine and there was no associated investigation into the issue.
- Observation 6
Obsolete procedures accessible in DMS
The quality control unit lacks responsibility to reject all procedures or specifications impacting on the quality of drug products. Specifically, Previously retired versions of standard operating procedures and forms are accessible for viewing for the end users of the electronic document management system entitled "Documentum Compliance Manager". A general search on the electronic document management system allows the end users to access these obsolete procedures.
- Observation 7
Lack of CPP rationale and supporting data
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, Critical Process Parameter (CPP) 105 Tablet distance processing range for the tablet process is established as cm to cm in the batch production record. However, there is no rationale or data to support the establishment of this range. Regarding this, Machine equipment qualification performed under Performance Qualification Protocol/Report of Machine Equipment Number MPDGAC03 Protocol No. PQ-MRL 12-00 approved on September 4, 2010 was performed at a set to distance value of @:m. Product development report titled Addendum II to Feasability Trial Report of Tablets mg report FSTR/03/0212-A02, approved on April 18, 2012 was performed at a to 5 distance range value of m to wom. Process validation report titled Process Performance Qualification (PPQ) Report of (Compression and Document R/E/PPQ/15/016/01, approved on March 14, 2016 was performed at a set to distance value of @:m.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 7 inspections.
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002807979, one row per refused product line.
1 refusal on 2026-09-14 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2026-09-14
MISCELLANEOUS PATENT MEDICINES, ETC.66VDY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-2289654-3/10002/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Sun Pharmaceutical Industries LimitedD-U-N-S 650172430
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Sun Pharmaceutical Industries Limited (D-U-N-S 650172430) as the registrant for this site and the 9 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Sun Pharmaceutical Industries LimitedHalol, India · FEI 300280958612 inspections12latestJun 13, 2025OAI2 warning letters, latest Dec 15, 2022
- Sun Pharmaceutical Industries LimitedDadra, India · FEI 30045615535 inspections5latestMar 29, 2019VAI1 warning letter, Jun 18, 2024
- Sun Pharmaceutical Industries LimitedAhmednagar, India · FEI 30032271536 inspections6latestSep 11, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedGurugram, India · FEI 30028714442 inspections2latestJul 31, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedVadodara, India · FEI 300452011312 inspections12latestJul 24, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedKanchipuram, India · FEI 30076276833 inspections3latestJul 18, 2025NAINone on file
- Sun Pharmaceutical Industries LimitedPanoli, India · FEI 30039527176 inspections6latestJun 13, 2025NAINone on file
- Sun Pharmaceutical Industries LimitedBharuch, India · FEI 30100271353 inspections3latestMay 17, 2024VAINone on file
- Sun Pharmaceutical Industries LimitedNew Delhi, India · FEI 30038929732 inspections2latestMar 17, 2023VAINone on file
Other FEIs recorded as Sun Pharmaceutical Industries Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Sun Pharmaceutical Industries LimitedFEI 3000481225Malanpur, India
Last inspected 2018-03-21NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002807979 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002807979. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.