Sun Pharmaceutical Industries Ltd.
Halol - Baroda Highway, Halol, India
FEI 3002809586DUNS 725959238
Company: Sun Pharmaceutical Industries Limited · Linked by exact D-U-N-S match (650172430) in FDA registration data
FDA has 12 inspections on file for Sun Pharmaceutical Industries Ltd. in Halol, India (FEI 3002809586), from 2011 to 2025. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Five of the 11 FOIA requests for this site have asked FDA for this inspection's 483.
FDA has issued 2 warning letters under this FEI, the latest on (CDER). 119 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
Nine regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Sun Pharmaceutical Industries Limited (D-U-N-S 650172430), has registered 9 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 12, 2011–2025
- 5 OAI · 4 VAI · 3 NAI
- Inspections with 483 observations shown
- 7 of 12
- Requested under FOIA
- 11 requests, latest FY2023
- Import refusals
- 119 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
12 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Show 3 more citations
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Written program not followed
The written stability testing program is not followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Show 5 more citations
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 3 more citations
Written in-process control procedures
Written procedures are not established and followed that describe the examinations to be conducted on appropriate samples of in-process materials of each batch.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic process procedures not followed
OBSERVATION 1 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. The Aseptic Process Validation Master Plan was not followed during execution of media fill run [illegible]. Specifically, [illegible] media fill failure on the [illegible] resulted in media fill failure with over [illegible] media batch contamination in the filled, incubated units. An investigation into the media fill failure determined that several 'new' operations occurred during this media fill run. These included the following that were either not recorded in detail as performed or not performed per written batch instructions: - Removal of the '<b><>' to the aseptically sealed tank containing sterile '<b><>' media. - Maintenance Activity to repair/reset the <b><> of the filling station and bevel gear due to reversal of <b><> movement resulting in intake of air instead of delivery of media. - Quality Assurance Impact Evaluation as part of the 'Breakdown Maintenance Report' regarding the filling station reversal (Sr. No. [<b><>]).
- Observation 2
Laboratory data review not documented
OBSERVATION 2 Established laboratory control mechanisms are not documented at the time of performance. The assurance of the data from the all analytical testing data is not provided. Specifically, Environmental monitoring of plates on June 5, 2019 included review of more than [illegible] sample sets. In my review of the data in support of the EM review, it was noted that in selected examples, the primary reviewer performed the plate analysis almost 2 hours prior to the witness review. As explained by your EM QC staff and detailed in written procedure SOP QCM-042, the witness is to perform the witness review of the reading of the EM plates at the same time as the primary review. For example, and as noted in the MODA system for EM data: (a) sample plate initial read/results entry: 10:09:05, review: 12:05:17 (b) sample plate initial read/results entry: 10:09:05, review: 12:05:17
Show observations 3 to 4
- Observation 3
Design plans inadequately established
OBSERVATION 3 Design plans that describe or reference the design and development activities and define responsibility for implementation have not been adequately established. Specifically, your design plan for ~b)() __(Injection, E_J<> pcg/mL, tbH > mL & tbH > mL) associated to <b><> was approved on May 20[illegible]. However, your firm began the design activities associated to this product on August 2012. Additionally, your firm did not have an established device history file that demonstrated conformance to an established design plan.
- Observation 4
Process validation/qualification inadequate
OBSERVATION 4 A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated according to established procedures. Specifically, the requalification of your [illegible] under Protocol No.: QUA-S/0253 Requalification Protocol/Report for [illegible] (equipment ID: 240) does not demonstrate that the air supply, assembly air, and clamp air pressures required per your reference document were challenged to determine optimal production parameters. According to your reference document, [illegible] Instruction approved on 12/07/2019, the pneumatic assembly machine requires an air supply of [illegible]; assembly air cylinders require [KbH> ± '<b><> si'] and clamp air cylinders require [bH> ± '<b><> si']. During the review of Protocol No.: QUA-S/0253, it was noted that the air supply pressure was recorded as ~bH> (approximately ~b><> psi). However, no other data was documented for the assembly air cylinders, the clamp air cylinders, and for the tolerances provided by your supplier. Moreover, the pneumatic assembly machine (ID: 240) was used to assemble exhibit lots associated to '(b)(4) _Jib)(4) (b)(4)'.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. For example, electronic data for mg exhibit batch for 0-month stability shows: dissolution at buffer stage L1 was conducted on 9/26/15 with results for the sampling time point at 5 hours, to have a minimum of] Blo release, a maximum of] 9% release and a mean of 47% release. The stability report STB4332 15 for the same batch and time point shows you conducted an L2 test. Based on the data contained in the report, the L2 was conducted with results to have a minimum of o % release, maximum of{y % release and a mean of 66% release. The chromatograms are reflective of variability between the L1 and L2 stages. Similar variability was seen for BB and | for L1 and L2 results for time 0-month for accelerated and intermediate stability repeat studies. You were unable to provide scientific justification for this variability.
- Observation 2
Failure to prevent objectionable microorganisms
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed. To date, no testing for burkholderia cepacia has been performed on 11 of the 12 products identified as having high®® content. On 3/14/17, you established Raw Material Specification Report WT001-BCC to test @® utilized as a raw material in the manufacture of drug products for the presence of burkholderia cepacia complex. On 5/1/18, you identified 12 finished drug products as having a high PE content. To date, you have initiated testing for burkholderia cepacia on™“ utilized to produce one product - 2 gel f%.
Show observations 3 to 6
- Observation 3
Insufficient stability sampling/statistics
The written stability program for drug products does not include sample size based on statistical criteria for each attribute examined to assure valid estimates of stability. Specifically, on 8/28/18, we observed unused stability samples stored inside a styrofoam cooler, on top of a stool, located inside stability chamber QCC-380, 25 degrees 60% relative humidity. Your Senior General Manager, Quality Non-Sterile Manufacturing, stated these were extra samples remaining from a completed stability study for ®®" product coded as Protocol of? tablets, f mg strength and they were being held in response to a request from the research and development site under protocol number SP1550 in case additional testing is required.
- Observation 4
Missing production/process control procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, there is no line clearance required during intervention activities performed by production operators. On 8/30/18 we observed capsule filling of batch of | capsules USP” mg being performed on capsule filling equipment HC-084. For no less than one hour and ten minutes, we observed the equipment to be intermittently operational. During this time, we observed production staff perform no less than three manual interventions in an attempt to clear a recurring critical alarm. In between these attempts, we observed capsules moving from the filling equipment, through the in-line check weight device and into the accepted capsule bag. We observed one operator performing interventions inside the ®®" access barrier (RABS) while wearing the protective goggles on top of his head rather than in an appropriate manner and observed use of a®® to remove “| and capsules from inside the filling equipment. After approximately one hour, the production staff requested assistance from the engineering department. Your Head of Operations, Solid Dosage, and your Senior General Manager, Quality Non-Sterile Manufacturing, stated that if the capsules pass the weight check, they are not rejected. Additionally, they stated there is no line clearance required during intervention activities performed by production operators. The same alarm occurred during production of the same lot on the ® . Filling machine HC-084 was also utilized to produce a characterization batch of” mg [7 on™ and is one of the filling machines intended to be utilized during commercial production of the ®* mg products.
- Observation 5
Lack of equipment cleaning procedures
Written procedures are not for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A) You performed equipment cleaning verification activities for a specific number of batches after you identified as a high risk product. During the cleaning verification you did not perform analyses for the detergent residues nor did you perform bio-burden testing. Your Deputy General Manager Quality Assurance stated that you are no longer performing sampling and testing for equipment utilized in the manufacture of ® drug products and are awaiting commercialization before completing cleaning validation activities. B) Your Vice President Operations stated that you did not conduct cleaning validation activities for the | used inside the capsule filling equipment to remove capsules and and consequently ensure no risk of cross contamination between drug products.
- Observation 6
QC unit responsibilities not documented
The responsibilities and procedures applicable to the quality control unit are not in writing. Specifically, your Head of Operations,” Solid Dosage and your Senior General Manager, Quality Non-Sterile Manufacturing stated that you do not have procedures in place which require across batch trending of critical alarms raised during production activities, such as those which occurred on capsule filling equipment ID HC-084 during filling of batch ®* of @ PO capsules USP ®“mg on and again while we were observing on 8/30/18.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling, testing, approval and rejection of drug product containers and closures.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Delayed/missing Field Alert Reports
OBSERVATION 1 Field Alert Reports were not submitted within three working days of receipt of information concerning bacteriological contamination and significant chemical, physical, or other change or deterioration in a distributed drug product. Specifically, 1) Investigation IN-JK-2015-0271 was initiated 05MAY2015 for dissolution failure of 18M long-term stability samples of Buproprion HCl extended release tablets, 200mg, Batch JKM4152A. An initial Field Alert Report (FAR) for batch JKM4152A was submitted to the agency 07MAY2015. Product impact assessment of the investigation included dissolution testing of reserve samples of Batch #'s JKM4737A and JKM5270A of Buproprion HCl extended release tablets, 200mg, completed 30-31MAY2015 with out-of-specification and borderline L3 results, respectively, recorded on 01JUN2015. However, no separate Field Alerts were submitted for the dissolution failure/borderline results of Batch #'s JKM4737A and JKM5270A, and no notice of their failing/borderline results were submitted to the agency until notification of their recall on 08JUL2015. No follow-up Field Alert was submitted for failing/borderline dissolution results of Batch #'s JKM4737A and JKM5270A, until final FAR submission for Batch JKM4152A on 31JUL2015. 2) OS-JK-2016-0749 was initiated 09OCT2016 for L3 dissolution failures of 23M control samples of Buproprion HCl extended release tablets, 150mg Batch #'s JKN5125A and JKN5232A, and the L1 failure of 23M control samples of Batch JKN5275A. 23M sample L1 failures were identified 07OCT2016, L2 failures were identified 11OCT2016, and L3 failures (high individual tablet and mean values at 2 and 4 hrs.) were identified 13OCT2016. A sufficient quantity of control samples of Batch JKN5275A was not available to perform L2 and L3 testing to confirm dissolution failure. An initial Field Alert for the 3 batches was submitted 24OCT2016. Incident IN-JK-2016-1378 was raised for the delayed FAR submission citing human error and referencing low risk as each of the batches were nearing their expiry. 3) OS-JK-2016-0275 was initiated 21APR2016 for L3 dissolution failure of 22M long-term stability samples of Buproprion HCl extended release tablets, 150mg Batch JKN0236A. 22M sample L1 failures were identified 07JAN2016, L2 failures were identified 13JAN2016, and L3 failures (5 high individual tablet values at 2 hrs. and high mean values at 2 and 4 hrs.) were not identified until [illegible]. A deviation for the excessive hold time between 22M stability sample withdrawal on 07DEC2015 and the start of analysis was documented in an “Analysis Time Deviation Register”. The entry states “Analysis not performed within timeline due to analyst busy with other priority work.” Incident IN-JK-2016-0461 was initiated 15APR2016 for the excessive delay of L3 testing of Batch JKN0236A. The analyst performing the 22M testing failed to identify the failing L2 results; a secondary review on 14FEB2016 by a Quality Control Supervisor failed to identify the failing L2 results; and the failure to progress to L3 testing was identified during Quality Assurance review on 13APR2016. No stability samples for Batch JKN0236A remained and control samples were used for L3 dissolution testing for 22M stability studies. No individual FAR was submitted for Batch JKN0236A and the OS-JK-2016 dissolution failure of Batch JKN0236A was not communicated to the agency until submission of a follow-up FAR for Batch JKN3477A on 13JUN2016. As Batch JKN0236A was expired at the time of the OS L3 testing, no immediate corrective action was taken. 4) OS-JK-2016-0546 was initiated 28JUL2016 for out-of-trend L2 dissolution results of 21M control samples of Buproprion HCl extended release tabs, 150mg Batch JKNS124A, at 2 hrs. 13 failures (high individual tablet and high average values at 2 and 4 hrs.) were then identified 31JUL2016 (at 21M shelf-life). Notice of the failure was not communicated to the agency until follow-up FAR submission for Batch JKN3477A
Shortened here; the PDF has the full text.
- Observation 2
Expiries unsupported by stability data
OBSERVATION 2 Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use. Specifically, the proposed expiries of Buproprion HCl extended release tablets of 150mg and 200mg strengths were based on 3M accelerated data for exhibit batches at the time of [illegible] filing. 24M of long-term data to support the proposed expiries were generated for exhibit batches as of 08AUG2008 and confirmed dissolution failures of samples at time points of 18-24M have been identified by (but not limited to) the following: 150mg + OS-JK-2014/314/2014, initiated 23SEP2014 for 24M long-term stability samples of Batch JKLA4403A + OS-JK-2016-0275, initiated 21APR2016 for 22M long-term stability samples of Batch JKN0236A + OS-JK-2016-0311, initiated 10MAY2016 for 21M control samples of Batch JKN3477A + OS-JK-2016-0546, initiated 28JUL2016 for 21M control samples of Batch JKNS124A + OS-JK-2016-0533, initiated 01AUG2016 for 21M control samples of Batch JKN5229A + OS-JK-2016-0749, initiated 09OCT2016 for 23M control samples of Batch #'s JKN5125A, JKN5232A, and JKN5275A + OS-JK-2016-0809, initiated 09NOV2016 for 24M control samples of Batch JKN35228A 200mg + OS-JK-2015-122/2015, initiated 05MAY2015 for 18M long-term stability samples of Batch JKM4152A + OS-JK-2016-0319, initiated 13MAY2015 for 23M control samples of Batch JKN2114A Investigation OS-JK-2016-0524 was initiated 26MAY2015 to include dissolution analysis of all live market batches of 150mg to be carried out at 15/18/21/24M of shelf life according to Protocol SUN/NS-SP/300/01, yet no revision of the assigned expiry period of Buproprion HCl extended release tablets has been submitted to the agency to date.
Show observations 3 to 7
- Observation 3
Stability testing schedule not followed
OBSERVATION 3 Testing programs are not adequately designed to assess the stability characteristics of drug products. Specifically, test schedules established by stability protocols are not adhered to so as to characterize the degradation of products over their actual shelf-lives. For example: - 24M stability samples of Buproprion HCl 150mg Batch JKL4403A (expiry [illegible]) were not analyzed until [illegible] (life) at which time dissolution failure was documented by OS-JK-2014/314/2014. No FAR was submitted for the 24M failure of Batch JKL4403A as it was expired at the time of analysis. - 22M stability samples of Buproprion HCl 150mg Batch JKN0236A (expiry [illegible]) were not analyzed until [illegible] of shelf-life) at which time dissolution failure was documented by OS-JK-2016-0275. No FAR was submitted for the 22M failure of Batch JKN0236A as it was expired at the time of analysis. - 18M stability samples of Buproprion HCl 200mg Batch JKM4152A (expiry [illegible]) were not analyzed until 04MAY2015 (20M of shelf-life) at which time dissolution failure was documented by OS-JK-2015-122/2015. An initial FAR was submitted for the 18M failure of Batch JKM4152A on 07MAY2015 and initial notice of its recall was submitted 08JUL2015 (22M of shelf-life). - 23M control samples of Buproprion HCl 200mg batch JKN2114A (expiry [illegible]) were not analyzed until [illegible] of shelf-life) at which time dissolution failure was documented by OS-JK-2016-0319. No FAR was submitted for the 23M failure of Batch JKN2114A as it was expired at the time of analysis.
- Observation 4
Test procedure changes not reviewed
OBSERVATION 4 The establishment of test procedures, including any changes thereto, are not adequately reviewed and approved by the quality control unit. Specifically, OS-JK-2016-0078 was initiated 02FEB2016 for OOS dissolution failure of finished product samples of [illegible] tablets, [illegible] Batch [illegible]. No root cause was identified during the laboratory investigation and the failure was referred to Production for investigation under IN-JK-2016-0151; IN-JK-2016-0151 identified no root cause of failure in production activities. A 21M MAY2016 addendum to the OOS investigations for Batch #'s [illegible] and [illegible] of [illegible] tablets references dissolution studies conducted by the [illegible] under Protocol MVT/244/2015 which identified the de-aeration of dissolution medium as the root cause of the failure of each batch. Data generated by [illegible] under Protocol MVT/244/2015 indicated an ~10% increased value of mean drug release when dissolution medium was not degassed. Analytical Test Procedures for [illegible] mg, [illegible] mg, and [illegible] mg for tablets were updated per Change Control CC-JK-2016-1335 on 10MAY2016 to preclude the de-aeration of dissolution medium. Re-analysis of each failing batch was performed according to a revised test method without de-aeration of dissolution medium with results for [illegible] active ingredients passing [illegible] criterion, and the batches were approved for release with the MAY 2016 closure of their respective investigations. However, 1) No assessment of the accuracy of dissolution data generated for batches tested and released under previous revisions of ATPs for [illegible] dosage strength (requiring de-gassing of dissolution medium) was performed upon implementation of CC-JK-2016-1335. For example, although original failing dissolution data sets for Batch #'s [illegible] (generated according to Revision 05 of ATP0011144) were invalidated and each batch was re-tested and released under Revision 06 of ATP0011144, there has been no re-evaluation of the accuracy of dissolution testing results generated for [illegible] batches generated and released under Revisions 00-05 of ATP0011144. 2) Although classified as a Level 2 “moderate” change, CC-JK-2016-1335 identifies no significant impact to quality or regulatory filing. It further states that notice of the method’s revision was to be submitted in the next Annual Product Report for [illegible] tabs. The analytical test procedure for dissolution submitted in [illegible] for [illegible] tablets, is silent on the requirement for de-aeration of dissolution medium, and no specific requirement to not de-aerate dissolution medium is noted in the USP monograph for [illegible] tablets. The change to the method approved in [illegible] for dissolution testing of [illegible] tablets without de-aeration of dissolution medium was implemented with no prior notice to or conference with the applicable CDER Reviewing Division, nor with the submission of any [illegible].
- Observation 5
Dissolution method accuracy not established
OBSERVATION 5 The accuracy of test methods has not been established. Specifically, validation of the dissolution test method for [illegible] tablets was performed according to Report MI/ANAR/210 (eff. 24SEP2005). It includes studies of specificity/selectivity, precision, intermediate precision, linearity and range. No specific evaluation of method accuracy was performed. Section 7 of Report MI/ANAR/210 contains no requirement to avoid de-aeration of dissolution medium as implemented with the 10MAY2016 revision of Analytical Test Procedures for [illegible] mg, [illegible] mg, and [illegible] mg strengths of [illegible] tablets under CC-JK-2016-1335. No re-validation was performed to assess the effect of the change on method accuracy prior to its implementation for testing of commercial and stability batches of [illegible] tablets.
- Observation 6
Inadequate laboratory controls and monitoring
OBSERVATION 6 Scientifically sound and appropriate laboratory control mechanisms are not established to assure that components, drug product containers, closures, in-process materials, or drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, 1) Upon visual inspection following incubation of Media Fill Batch [illegible] executed on [illegible] fill on Line [illegible] and simulated [illegible] vials using the [illegible], the entirety of Population-1 and -2 were suspected for turbidity and Incident IN-JK-2015-0137 was initiated. A [illegible] unit from Run of Population-1 (vials total) and a [illegible] unit from Population-2 were sent to the Microbiology Laboratory for evaluation. The notebook of Analyst [illegible], 568/2014, documents loading of the samples at [illegible] °C into Incubator QCC1090 from [illegible] and initial visual inspection at [illegible]. A repeat visual inspection of the samples was performed following additional incubation at [illegible] °C on [illegible] and a third re-inspection of the samples was performed following additional incubation at [illegible] °C on [illegible], each of which identified no turbidity. The vials were then returned back to QA for reunion with Batch [illegible]. The remainder of Population-1 and -2 of Batch [illegible] immediately incubated at [illegible] °C for an additional [illegible] hours. No standard operating procedure for the assessment of turbid containers was in effect prior to 22JUL2015, and no cultivation of the contents of the suspected turbid vials of Media Fill Batch [illegible] was performed to confirm and identify (or disprove) contamination either prior to or following incubation at [illegible] °C. 2) Re-validation of disinfectant efficacy failed to include an evaluation of a specific organism isolated from various means of sampling throughout ISO classified clean areas, namely Staphylococcus cohnii. For example, OOS #08-JK-2015 (Trackwise PR No. 49522) was created on 02OCT2015 due to a case of disinfectant efficacy studies failing to achieve a 5 log reduction of test organisms. Instead, less than 1 log reduction was achieved during the in process step of [illegible] capsule [illegible] mg Batch [illegible]. The isolated organism recovered during the incident was Staphylococcus cohnii. Re-validation of disinfectant efficacy included an evaluation of ATCC test organisms specified by USP plus in-house isolates, but failed to include an evaluation of efficacy against Staphylococcus cohnii. 3) Trend data for Personnel Monitoring of the [illegible] for the months of September and October 2016, identifies the following: a. On 26OCT2016, chest samples from operator [illegible] in an ISO Grade B area resulted in over-action limit (OAL) recovery of 15 cfu/plate (investigation referred to Trackwise PR 128627, not yet completed); b. On 25OCT2016, right hand glove samples from operator [illegible] in an ISO Grade B area resulted in OAL recovery of 7 cfu/plate (investigation referred to PR 128627, not yet completed); c. On 18OCT2016, right hand glove samples from operator [illegible] in an ISO Grade B area resulted in OAL recovery of 7 cfu/plate (investigation referred to PR 127171); d. On 14SEP2016, right and left hand glove samples from operator [illegible] in an ISO Grade B area resulted in OAL recoveries of 12 cfu/plate and 6 cfu/plate, respectively (referred to PR 120333); e. On 17SEP2016, right hand glove samples from operator [illegible] in an ISO Grade B area resulted in OAL recovery of 7 cfu/plate (referred to PR 120333); f. On 17SEP2016, forearm and goggle samples from operator [illegible] in an ISO Grade B area resulted in OAL recoveries of [illegible] cfu/plate for each (referred to PR 120333); g. On 14SEP2016, right and left hand glove samples from operator [illegible] in an ISO Grade A area resulted in OAL recoveries of [illegible] cfu/plate and 6 cfu/plate, respectively (referred to PR 120333); h. On 14SEP201
Shortened here; the PDF has the full text.
- Observation 7
Quality unit procedures not followed
OBSERVATION 7 The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, 1) L1/476/2014 was initiated 04SEP2014 for 3 dissolution failure of 3M long-term samples of [illegible] tablets, Batch No [illegible]. No assignable root cause was identified during the laboratory investigation, an initial Field Alert Report for Batch [illegible] was submitted on 10SEP2014, the investigation was extended as ER-QCC-14/189 and no assignable root cause was identified in production. Upon release testing, Batch [illegible] was passing at [illegible] only. Review of dissolution result trend data for batches of similar age or older than the subject batch identified one additional batch released after meeting release criteria. Although failing at 3M for low release and no assignable root cause could be identified, long-term stability test data for the 6M time point (28NOV2014) met acceptance criteria as of the time of investigation closure on 20JAN2015. SOP QA-014/08 specifics that product recall may need to be carried out for failure to meet regulatory specification/observation of quality defects, yet no market action was taken for Batch [illegible] from SEP2014. Additionally, no market action was initiated for the other batch meeting 3M criteria upon release, Batch [illegible]. No Health Hazard Evaluations for Batch #'s [illegible] and [illegible] were performed. 2) 14/060 was reported 09DEC2014 for 1 turbid vial from Population-1 and 1 turbid vial from Population-2 of Media Fill Batch following 14 days incubation. Probable root cause of the turbid vial in Population-1 was identified as the failure to [illegible] forceps following the simulated [illegible] of the stopper chute and the clearance of stopper jams. Probable root cause of the turbid vial in Population-2 was identified as poor aseptic technique prior to and during the simulated removal of broken vials. Both interventions were performed by the same Production Operator who was properly trained in aseptic technique and fully qualified for aseptic operations at the time of contaminations. Prior to the 22NOV2014 fill of Batch [illegible] the most-recent successful media fill on Line was performed in April 2014 (Batch [illegible]). The product impact assessment performed as part of Investigation 14/060 consists of a summary of the results for non-viable particulate count, surface examination, active air sampling, swab sampling, in-process [illegible] and finished product sterility test data. The impact assessment fails to include a summary evaluation of personnel monitoring. 3) SOP QA-047 (rev. 07, eff. 14SEP2016) establishes general rules for personnel to follow good documentation practices during manufacturing activities. However, repeated failures to adhere to the requirements of SOP QA-047 include the following: a) Manufacturing Investigation 14/061 was initiated 12DEC2014 for 1 turbid vial from Population-2 of Media Fill Batch following 14 days incubation. Media Fill Batch simulated sterile liquid filling on Line [illegible] the firm's commitment to demonstrate a successful process simulation on production line following the previous U.S. FDA inspection. Organisms from the turbid vial from Population-2 (Media Fill Run [illegible] ...
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
11 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Jun 13, 2025OAI
5 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 8, 2025FDA-FOIA-2025-8393Form 483Records released
- Jul 8, 2025FDA-FOIA-2025-8378Form 483Records released
- Jun 17, 2025FDA-FOIA-2025-7718Form 483Records released
- Jun 16, 2025FDA-FOIA-2025-7669Form 483Records released
- Jun 14, 2025FDA-FOIA-2025-7658Form 483Records released
Inspection ending May 9, 2022OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2023-17Form 483Closed
Inspection ending Jun 11, 2019VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2023-5037Inspection recordsClosed
Inspection date not given
4 requests. FDA released records in answer to a request for its Form 483 on Jul 15, 2025. FDAgent holds no copy that FDA posted.
- FY2023FDA-FOIA-2023-3103Form 483Closed
- Jun 20, 2025FDA-FOIA-2025-7859Form 483Records released
- Jun 16, 2025FDA-FOIA-2025-7670Form 483Records released
- May 10, 2022FDA-FOIA-2022-3357Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 12 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 4
- 21 CFR 211.67Equipment cleaning and maintenance3 of 4
- 21 CFR 211.113Control of microbiological contamination3 of 4
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.192Production record review3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.63Equipment design, size, and location2 of 4
- 21 CFR 211.100Written procedures; deviations2 of 4
Show all 13
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.80General requirements1 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.166Stability testing1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002809586, one row per refused product line.
119 refusals from 2022-10-21 to 2026-10-02 · charged DRUG GMPS on 113, UNAPPROVED on 24 · FDA sample analysis on 1
FDA firm profile- 2026-10-02
ROSUVASTATIN CALCIUM61JCH16
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-8761269-3/10002/1
- 2026-09-30
ESCITALOPRAM OXALATE61NCA83
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-4920101-3/10003/1
- 2026-07-24
LETROZOLE (ANTI-NEOPLASTIC)62ICA85
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-0834626-3/10002/1
- 2026-07-07
LETROZOLE (ANTI-NEOPLASTIC)62ICA85
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsAEK-0329279-3/50002/1
- 2026-06-26
ANTI-HISTAMINIC N.E.C.61XDY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-9751970-5/20002/2
Show 114 more
- 2026-04-24
LEUPROLIDE ACETATE (ANTI-NEOPLASTIC)62ICY86
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsAEK-7736330-5/10003/1
- 2025-11-25
TOBRAMYCIN (ANTI-MICROBIAL)62HDY02
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7487919-1/20003/1
- 2025-11-25
CARBOXYMETHYLCELLULOSE SODIUM, EMOLLIENT,LUBRICANT64DDY01
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-7487919-1/10003/1
- 2025-08-13
ANTI-NEOPLASTIC N.E.C.62ICA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-7401410-9/10002/1
- 2025-06-26
METOPROLOL SUCCINATE (ANTI-HYPERTENSIVE - PART II)62OCY43
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-1070631-0/112/1
- 2025-06-11
ANALGESIC, N.E.C.60LCA99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-1117084-7/32/1
- 2025-06-11
MONTELUKAST SODIUM (ANTI-ASTHMATIC)61EBY09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-1117084-7/102/1
- 2025-06-05
TIMOLOL MALEATE (ANTI-ADRENERGIC)60XDY23
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsAEK-7182928-5/12/1
- 2025-06-04
IVERMECTIN (ANTI-PROTOZOAL, A-LEISHMANIAL, ANTI-MALARIAL)62LCA47
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-9657915-0/11/1
- 2025-04-14
ADRENERGIC N.E.C.60CDB99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-9331616-8/101/1
- 2025-04-03
BUDESONIDE (ANTI-ASTHMATIC)61ECE04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsAEK-8405992-0/31/1
- 2025-03-10
ESCITALOPRAM OXALATE61NCA83
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-8502139-6/21/1
- 2025-03-10
ESCITALOPRAM OXALATE61NCA83
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-8502139-6/11/1
- 2025-02-27
BUDESONIDE (ANTI-ASTHMATIC)61ECY04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast Imports799-5962715-0/11/1
- 2025-01-16
ULTRAVIOLET SCREEN/SUNSCREEN N.E.C.66PDO99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-7804712-7/91/1
- 2025-01-16
ITRACONAZOLE (ANTI-FUNGAL) (NOT ANTIBIOTIC)61WCY46
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-7804712-7/51/1
- 2025-01-10
ROSUVASTATIN CALCIUM61JCY16
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-8148558-7/31/1
- 2025-01-07
MONTELUKAST SODIUM (ANTI-ASTHMATIC)61EBY09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-8099625-3/61/1
- 2024-11-27
ROSUVASTATIN CALCIUM61JCA16
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-7222988-7/51/1
- 2024-11-21
ROSUVASTATIN CALCIUM61JCA16
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-6967693-4/21/1
- 2024-10-17
IMATINIB MESYLATE (IMMUNOSUPPRESSIVE)64TCA09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7173238-1/31/1
- 2024-10-07
ROSUVASTATIN CALCIUM61JCA16
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-5447676-1/31/1
- 2024-10-01
ESOMEPRAZOLE MAGNESIUM (ANTI-SECRETORY)62TDB06
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-5906188-1/11/1
- 2024-09-27
ANTACID, N.E.C.60SCS99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-6030612-7/21/1
- 2024-09-27
ANTI-INFLAMMATORY N.E.C.62GCA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-5720553-0/11/1
- 2024-07-25
ATORVASTATIN CALCIUM (ANTI-CHOLESTEREMIC)61JDC08
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast ImportsSCS-4815617-2/11/4
- 2024-07-23
ANTI-CHOLESTEREMIC, N.E.C.61JDB99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-4661730-8/21/1
- 2024-07-17
DIGOXIN (CARDIOTONIC)63FCA06
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports551-1737177-0/11/1
- 2024-07-16
ETHINYL ESTRADIOL (ESTROGEN)64GDC19
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-3818841-7/11/1
- 2024-05-28
RIFAXIMIN (A-BACTERIAL PT. I) (NOT ANTIBIOTIC)61FCA63
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3867578-5/21/1
- 2024-05-24
CALCIUM CHLORIDE (REPLENISHER)65RDY01
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsAEK-5221957-1/11/1
- 2024-05-16
GLIMEPIRIDE (ANTI-DIABETIC)61PDC31
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3978628-4/11/1
- 2024-05-14
PAROXETINE (ANTI-DEPRESSANT)61NCE76
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-4127736-3/31/1
- 2024-05-06
QUETIAPINE FUMARATE (TRANQUILIZER (ANTI-PSYCHOTIC) - PART II)66NCA03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3899652-0/31/1
- 2024-04-24
ESOMEPRAZOLE MAGNESIUM (ANTI-SECRETORY)62TCS06
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3768939-9/71/1
- 2024-04-24
METOPROLOL SUCCINATE (ANTI-HYPERTENSIVE - PART II)62OCY43
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3768939-9/41/1
- 2024-04-17
ATORVASTATIN CALCIUM (ANTI-CHOLESTEREMIC)61JIY08
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3595506-5/41/1
- 2024-03-26
LETROZOLE (ANTI-NEOPLASTIC)62ICA85
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border ImportsAEK-4888092-4/11/1
- 2024-03-21
ANTI-INFLAMMATORY N.E.C.62GCA99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3218328-1/41/1
- 2024-03-15
CLOPIDOGREL BISULFATE (ANTI-COAGULANT)61LDA38
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3204094-5/51/1
- 2024-03-15
NAPROXEN (ANTI-INFLAMMATORY)62GIC49
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-3204094-5/41/1
- 2024-02-22
MONTELUKAST SODIUM (ANTI-ASTHMATIC)61EBY09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-2880127-6/51/1
- 2024-02-22
AMOXICILLIN TRIHYDRATE (PENICILLIN, SYNTHETICALLY PRODUCED)56BCA03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-2880127-6/11/1
- 2023-12-22
LETROZOLE (ANTI-NEOPLASTIC)62IDY85
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsAEK-4462714-7/41/1
- 2023-11-22
A-FUNGAL N.E.C.61WCJ99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-1221588-9/11/1
- 2023-11-06
SILVER NITRATE (ANTI-INFECTIVE, TOPICAL)62FDO36
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-0816627-8/21/4
- 2023-09-28
METHOTREXATE (ANTI-NEOPLASTIC)62ICA31
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-6741177-8/51/1
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7148352-2/11/4
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7148352-2/11/3
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7148352-2/11/2
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7148352-2/11/1
- 2023-05-10
SUMATRIPTAN SUCCINATE (ANTIMIGRAINE AGENT)63OCP07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/31/1
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/21/3
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/21/2
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/21/1
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/11/2
- 2023-05-10
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northeast Imports316-7147803-5/11/1
- 2023-03-28
DILTIAZEM HYDROCHLORIDE (ANTI-HYPERTENSIVE - PART II)62OCE24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
FDA sample analysis
Division of Northeast Imports316-0850058-8/31/1
- 2023-02-23
SUMATRIPTAN SUCCINATE (ANTIMIGRAINE AGENT)63OCP07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148600-4/31/2
- 2023-02-23
SUMATRIPTAN SUCCINATE (ANTIMIGRAINE AGENT)63OCP07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148600-4/31/1
- 2023-02-23
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148600-4/11/2
- 2023-02-23
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148600-4/11/1
- 2023-02-23
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148290-4/21/1
- 2023-02-23
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148290-4/11/2
- 2023-02-23
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148290-4/11/1
- 2023-02-10
LEVODOPA (ANTI-PARKINSONIAN)62JDA09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/91/1
- 2023-02-10
LEVODOPA (ANTI-PARKINSONIAN)62JDA09
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/81/1
- 2023-02-10
CAPECITABINE (ANTI-NEOPLASTIC)62ICA72
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/61/2
- 2023-02-10
CAPECITABINE (ANTI-NEOPLASTIC)62ICA72
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/61/1
- 2023-02-10
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/51/2
- 2023-02-10
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/51/1
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/41/2
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/41/1
- 2023-02-10
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148291-2/31/1
- 2023-02-10
TRAMADOL HCL (ANALGESIC)60LCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/81/2
- 2023-02-10
TRAMADOL HCL (ANALGESIC)60LCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/81/1
- 2023-02-10
DILTIAZEM HYDROCHLORIDE (ANTI-HYPERTENSIVE - PART II)62OCE24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/41/1
- 2023-02-10
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/31/1
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/21/3
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/21/2
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148079-1/21/1
- 2023-02-10
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148078-3/51/1
- 2023-02-10
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148078-3/31/1
- 2023-02-02
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044710-3/11/2
- 2023-02-02
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044710-3/11/1
- 2023-02-01
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044709-5/11/2
- 2023-02-01
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044709-5/11/1
- 2023-02-01
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044341-7/31/2
- 2023-02-01
TAMSULOSIN HCL (REGULATOR)65PCE03
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044341-7/31/1
- 2023-02-01
VENLAFAXINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsCID-2044341-7/21/1
- 2023-02-01
VENLAFAXINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148591-5/51/2
- 2023-02-01
VENLAFAXINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148591-5/51/1
- 2023-02-01
METFORMIN HCL (ANTI-DIABETIC)61PCB55
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148591-5/41/1
- 2023-02-01
VENLAFAXINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148591-5/21/2
- 2023-02-01
VENLAFAXINE HYDROCHLORIDE (ANTI-DEPRESSANT)61NCA80
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148591-5/21/1
- 2023-02-01
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/71/2
- 2023-02-01
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/71/1
- 2023-02-01
GABAPENTIN (ANTI-DEPRESSANT)61NCA69
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/51/1
- 2023-02-01
PHENYTOIN SODIUM (ANTI-CONVULSANT)61MCF24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/41/5
- 2023-02-01
PHENYTOIN SODIUM (ANTI-CONVULSANT)61MCF24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/41/4
- 2023-02-01
PHENYTOIN SODIUM (ANTI-CONVULSANT)61MCF24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/41/3
- 2023-02-01
PHENYTOIN SODIUM (ANTI-CONVULSANT)61MCF24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/41/2
- 2023-02-01
PHENYTOIN SODIUM (ANTI-CONVULSANT)61MCF24
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/41/1
- 2023-02-01
SUMATRIPTAN SUCCINATE (ANTIMIGRAINE AGENT)63OCP07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148325-8/31/1
- 2023-01-27
METHYLPREDNISOLONE (GLUCOCORTICOID)64LCA44
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southeast ImportsSCS-5828558-9/11/4
- 2022-12-30
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148354-8/11/3
- 2022-12-30
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148354-8/11/2
- 2022-12-30
KETOROLAC TROMETHAMINE (ANTI-INFLAMMATORY)62GCK94
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7148354-8/11/1
- 2022-12-30
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7144484-7/11/5
- 2022-12-30
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7144484-7/11/4
- 2022-12-30
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7144484-7/11/3
- 2022-12-30
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7144484-7/11/2
- 2022-12-30
AZELASTINE HYDROCHLORIDE/FLUTICASONE, ANTI-HISTAMINE STEROID (ANTI-HISTAMINIC)61XCP50
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northeast Imports316-7144484-7/11/1
- 2022-10-21
ANTI-INFLAMMATORY N.E.C.62GDB99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-1343640-8/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Sun Pharmaceutical Industries LimitedD-U-N-S 650172430
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Sun Pharmaceutical Industries Limited (D-U-N-S 650172430) as the registrant for this site and the 9 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Sun Pharmaceutical Industries LimitedDadra, India · FEI 30045615535 inspections5latestMar 29, 2019VAI1 warning letter, Jun 18, 2024
- Sun Pharmaceutical Industries LimitedAhmednagar, India · FEI 30032271536 inspections6latestSep 11, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedGurugram, India · FEI 30028714442 inspections2latestJul 31, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedVadodara, India · FEI 300452011312 inspections12latestJul 24, 2026NAINone on file
- Sun Pharmaceutical Industries LimitedKanchipuram, India · FEI 30076276833 inspections3latestJul 18, 2025NAINone on file
- Sun Pharmaceutical Industries LimitedPanoli, India · FEI 30039527176 inspections6latestJun 13, 2025NAINone on file
- Sun Pharmaceutical Industries LimitedBharuch, India · FEI 30100271353 inspections3latestMay 17, 2024VAINone on file
- Sun Pharmaceutical Industries LimitedNew Delhi, India · FEI 30038929732 inspections2latestMar 17, 2023VAINone on file
- Sun Pharmaceutical Industries LimitedMohali, India · FEI 30028079797 inspections7latestAug 12, 2022OAINone on file
Other FEIs recorded as Sun Pharmaceutical Industries Ltd.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Sun Pharmaceutical Industries Ltd.FEI 3012032037Ankleshwar, India
Last inspected 2024-01-19NAI
Sun Pharmaceutical Industries Ltd.FEI 3008238703Vadodara, India
Last inspected 2018-03-13NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002809586 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002809586. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.