Skip to content

Sun Pharmaceutical Industries Ltd Form 483, August 2018

FDA issued this Form 483 to Sun Pharmaceutical Industries Ltd in Halol, India (FEI 3002809586) at the end of a drug inspection that ended August 31, 2018. It lists 6 observations. FDA classified the inspection No Action Indicated (NAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Sep 10, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 31, 2018
Drugs · Drug Quality Assurance
FDA's outcome
NAI
No Action Indicated
Posted by FDA
Sep 10, 2018
10 days after the inspection
Facility
FEI 3002809586
Halol, India

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. For example, electronic data for mg exhibit batch for 0-month stability shows: dissolution at buffer stage L1 was conducted on 9/26/15 with results for the sampling time point at 5 hours, to have a minimum of] Blo release, a maximum of] 9% release and a mean of 47% release. The stability report STB4332 15 for the same batch and time point shows you conducted an L2 test. Based on the data contained in the report, the L2 was conducted with results to have a minimum of o % release, maximum of{y % release and a mean of 66% release. The chromatograms are reflective of variability between the L1 and L2 stages. Similar variability was seen for BB and | for L1 and L2 results for time 0-month for accelerated and intermediate stability repeat studies. You were unable to provide scientific justification for this variability.

  2. 2

    Failure to prevent objectionable microorganisms

    Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed. To date, no testing for burkholderia cepacia has been performed on 11 of the 12 products identified as having high®® content. On 3/14/17, you established Raw Material Specification Report WT001-BCC to test @® utilized as a raw material in the manufacture of drug products for the presence of burkholderia cepacia complex. On 5/1/18, you identified 12 finished drug products as having a high PE content. To date, you have initiated testing for burkholderia cepacia on™“ utilized to produce one product - 2 gel f%.

  3. 3

    Insufficient stability sampling/statistics

    The written stability program for drug products does not include sample size based on statistical criteria for each attribute examined to assure valid estimates of stability. Specifically, on 8/28/18, we observed unused stability samples stored inside a styrofoam cooler, on top of a stool, located inside stability chamber QCC-380, 25 degrees 60% relative humidity. Your Senior General Manager, Quality Non-Sterile Manufacturing, stated these were extra samples remaining from a completed stability study for ®®" product coded as Protocol of? tablets, f mg strength and they were being held in response to a request from the research and development site under protocol number SP1550 in case additional testing is required.

  4. 4

    Missing production/process control procedures

    There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, there is no line clearance required during intervention activities performed by production operators. On 8/30/18 we observed capsule filling of batch of | capsules USP” mg being performed on capsule filling equipment HC-084. For no less than one hour and ten minutes, we observed the equipment to be intermittently operational. During this time, we observed production staff perform no less than three manual interventions in an attempt to clear a recurring critical alarm. In between these attempts, we observed capsules moving from the filling equipment, through the in-line check weight device and into the accepted capsule bag. We observed one operator performing interventions inside the ®®" access barrier (RABS) while wearing the protective goggles on top of his head rather than in an appropriate manner and observed use of a®® to remove “| and capsules from inside the filling equipment. After approximately one hour, the production staff requested assistance from the engineering department. Your Head of Operations, Solid Dosage, and your Senior General Manager, Quality Non-Sterile Manufacturing, stated that if the capsules pass the weight check, they are not rejected. Additionally, they stated there is no line clearance required during intervention activities performed by production operators. The same alarm occurred during production of the same lot on the ® . Filling machine HC-084 was also utilized to produce a characterization batch of” mg [7 on™ and is one of the filling machines intended to be utilized during commercial production of the ®* mg products.

  5. 5

    Lack of equipment cleaning procedures

    Written procedures are not for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A) You performed equipment cleaning verification activities for a specific number of batches after you identified as a high risk product. During the cleaning verification you did not perform analyses for the detergent residues nor did you perform bio-burden testing. Your Deputy General Manager Quality Assurance stated that you are no longer performing sampling and testing for equipment utilized in the manufacture of ® drug products and are awaiting commercialization before completing cleaning validation activities. B) Your Vice President Operations stated that you did not conduct cleaning validation activities for the | used inside the capsule filling equipment to remove capsules and and consequently ensure no risk of cross contamination between drug products.

  6. 6

    QC unit responsibilities not documented

    The responsibilities and procedures applicable to the quality control unit are not in writing. Specifically, your Head of Operations,” Solid Dosage and your Senior General Manager, Quality Non-Sterile Manufacturing stated that you do not have procedures in place which require across batch trending of critical alarms raised during production activities, such as those which occurred on capsule filling equipment ID HC-084 during filling of batch ®* of @ PO capsules USP ®“mg on and again while we were observing on 8/30/18.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3002809586, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.