Sun Pharmaceutical Industries Ltd. Form 483, June 2025

FDA issued this Form 483 to Sun Pharmaceutical Industries Ltd. in Halol, India (FEI 3002809586) at the end of a drug inspection that ran from June 2 to June 13, 2025. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 9, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection
Jun 2–13, 2025
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jul 9, 2025
26 days after the inspection
Facility
FEI 3002809586
Halol, India

FDA's 8 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Prepared for each batch, include complete information

    Batch production and control records do not include complete information relating to the production and control of each batch.

  2. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  3. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  4. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  5. Absence of Written Procedures

    Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

  6. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

  7. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

  8. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3002809586, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.