Buildings, facilities and HVAC in FDA Form 483 observations
The plant itself: building design and repair, air handling, pressure differentials, temperature and humidity. FDAgent finds 160 such observations in 121 Form 483s issued to 117 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 160
- Each quoted below
- Form 483s
- 121
- Posted by FDA
- Facilities
- 117
- Distinct FEIs
- Most recent
- Sep 10, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 49 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 1 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 1 |
| 2013 | 1 |
| 2014 | 8 |
| 2015 | 7 |
| 2016 | 4 |
| 2017 | 6 |
| 2018 | 9 |
| 2019 | 9 |
| 2020 | 2 |
| 2021 | 8 |
| 2022 | 15 |
| 2023 | 8 |
| 2024 | 18 |
| 2025 | 13 |
| 2026 | 49 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.4221 CFR 211.4421 CFR 211.4621 CFR 211.4821 CFR 211.5021 CFR 211.5221 CFR 211.58
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“HVAC” · “air handl*” · “AHU*” · “pressure differential*” · “differential pressure*” · “temperature and humidity” · “humidity control*” · “humidity monitor*” · “air change*” · “air filtration” · “state of repair” · “ceiling tile*” · “peeling” · “flaking” · “water leak*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 160 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 3
… D) Three (3) deviations in 2025 and two (2) deviations in 2026 were initiated to document HVAC failures resulting in out of specification (OOS) temperature and humidity in the ISO 7 cleanrooms. The root causes for each of the events are documented as indicated below. Despite repeated HVAC failures, your quality unit has not initiated preventative actions. Your quality unit released approximately (b)(4) lots of product without verifying HEPA …
Contains “HVAC”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 5
You did not implement procedures to ensure that all equipment is cleaned and suitable for its intended purposes that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. Specifically, You failed to monitor the pressure differential of ISO 5 Laminar Flow Hood (#(b) (4)), to ensure the pressure differential across the …
Contains “pressure differential*”Read the Form 483 →
JOINN Laboratories (Suzhou) Co. LtdInspection ended May 15, 2026 · FEI 3012611386 · Observation 1
… Hygrometers used for monitoring environmental temperature and humidity (excluding EBl system monitoring probes)." The Room Temperature and Humidity Record (Form BA-041-F03) for Room 8237 recorded temperature and humidity readings twice daily without applying the corrected values from April 2, 2026, through May 12, 2026.
Contains “temperature and humidity”Read the Form 483 →
QuVa Pharma IncInspection ended May 4, 2026 · FEI 3012053582 · Observation 3
Buildings used in the manufacturing, processing, packing and holding of [illegible] maintained in a good state of repair. Specifically, on 4/20/2026, during a site walk-through I observed paint peeling off Suite 3 ISO 8 Degowning Room wall corners and around the door frame.
Contains “state of repair”Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, the following discrepancies were noted during review of the environmental monitoring program: A. Not all (b) (4) used during aseptic filling of injectable products are sampled at the end of the batch. C-VP-206-71000-2617 Risk Assessment of Environmental Control in Workshop (b) (4) specifies sampling of (b) (4) to monitor after batch …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Nice-Pak Products, LLCInspection ended Apr 20, 2026 · FEI 1822410 · Observation 3
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair. Specifically, Ceiling tiles located directly above active manufacturing equipment and the production line were observed to be damaged, missing, and visibly contaminated. Numerous tiles exhibited water stains, dirt, and large, dark patches consistent in appearance with mold, creating a direct risk of contamination to exposed drug products and …
Opens with FDA's citation wording for 21 CFR 211.58Read the Form 483 →
USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 2
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, Aseptic processing operations fail to provide adequate protection of Grade A (ISO Class 5) environments and first air over critical exposure points. For example: A. Rooms (b) (4) (Vial Filling and Sealing) and (b) (4) Filling): Grade A (b) (4) laminar airflow areas are separated from Grade …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 4
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Environmental Monitoring 1. Adequate risk assessment could not be provided for changing viable surface monitoring from RABs, are (b)(4) located in the (b)(4) to (b)(4) These (b)(4) for the (b)(4) used to handle settle plates during environmental monitoring. 2. Recovery studies have not been performed that show using one swab (b)(4) of a (b)(4) …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)(iv)Read the Form 483 →
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 5
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. The following discrepancies were noted during review of the aseptic filling lines for the following: (b)(4) API (b)(4) 1. On April 9, 2026, I observed your firm failed to maintain equipment in a clean and orderly manner. The (b)(4) Sterile (b)(4) equipment (b)(4) was found to have the following …
Opens with FDA's citation wording for 21 CFR 211.42(c)(10)Read the Form 483 →
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 9
The (b)(4) method (b)(4) used to test (b)(4) has not been proven to be better than or equal to the USP method. The firm's procedure does not include a (b)(4) with their edges peeling On 7Apr2026, I observed (b)(4) (b)(4) off the (b)(4)
Contains “peeling”Read the Form 483 →
Pharmaneek IncInspection ended Apr 8, 2026 · FEI 3014484244 · Observation 3
Your facility is not maintained in a good state of repair, creating insanitary conditions whereby drug products may be contaminated with filth. Specifically, On 03/30/2026, a ceiling tile in the control room where Hydroxyurea 100 mg/mL Oral Suspension, Lot HU10010330260 (Date Made: 03/30/26, BUD: 04/29/26) was produced, and subsequently dispensed to the patient, was observed to be chipped, with part of the ceiling tile missing and opened to the …
Contains “state of repair”Read the Form 483 →
ChemPacific CorporationInspection ended Apr 7, 2026 · FEI 3003299802 · Observation 4
Buildings used in the manufacture, processing, packing, or holding of intermediates and API are not maintained in a good state of repair and kept in a clean condition. Specifically, Your firm has not maintained facility ceilings in critical GMP areas in a good state of repair. For example, during a facility walkthrough on 03/30/2026, it was observed that Room (b)(4), designated as "GMP Raw Material (Quarantine)," had damaged and discolored …
Contains “state of repair”Read the Form 483 →
Adimmune CorporationInspection ended Apr 2, 2026 · FEI 3008919998 · Observation 3
… Procedures have not been established as part of the (b) (4) preventative maintenance protocol to ensure the (b) (4) system is maintained in a good state of repair. (b) (4) accumulation was found (b) (4) (b) (4) of the facility (b) (4) system (b) (4). Additionally, deterioration of the (b) (4) on (b) (4) was observed.
Contains “state of repair”Read the Form 483 →
Spectrum Laboratory Products Inc.Inspection ended Mar 20, 2026 · FEI 2020632 · Observation 2
… The hoods exhibited corrosion, permanent staining, flaking paint, and accumulation of residue and dust. These hoods are used for reagent preparation and analytical testing of APIs and raw materials. The condition of these hoods presents a potential risk of contamination to materials and test results. b) Inadequate Cleaning Procedures: Your SOP QC-W-8.22, "Analytical Laboratory Cleaning," does not specify approved cleaning agents or sanitizing …
Contains “flaking”Read the Form 483 →
Bausch and Lomb IncorporatedInspection ended Mar 20, 2026 · FEI 1000113778 · Observation 2
… Your firm failed to identify a water leak from the (b) (4) collection port (b) (4) (outlet side of 1 pump). In 2024, your firm recovered gram negative Burkholderia cepacia twice in your (b) (4) monitoring in port (b) (4) located in the non-sterile compounding area (b) (4) next to the (b) (4) testing sink. No daily walkthrough log is in existence for water system monitoring to ensure the system is in a good state of repair. Water system operator …
Contains “water leak*”Read the Form 483 →
Protein Sciences CorporationInspection ended Mar 17, 2026 · FEI 3011286996 · Observation 1
… Approximately (b)(4) labels were observed as peeling off their respective (b)(4) contents, potentially compromising the ability to identify (b)(4). Master cell banks and working cell banks are stored (b)(4) differentiated only by (b)(4) location. Similarly, master virus banks and working virus banks for baculovirus are [illegible]. Additionally, your firm's stored (b)(4) (virus bank storage), (b)(4) (cell bank storage), and (b)(4) (backup) are …
Contains “peeling”Read the Form 483 →
Hospira, Inc.Inspection ended Mar 10, 2026 · FEI 1925262 · Observation 3
Observation 3: Failure to maintain equipment and facilities in a good state of repair in fy drug product manufacture. Specially. a. Thee used in ge drug product manufacture was observed with deteriorated sealant at ga mounting. The ge near the stoppering system was observed with extensive scoring. b. CA was observed with gy line to an open bucket, along with me below the ge ate locations. QI) was observed with an unsecured electrical box, ay leak …
Contains “state of repair”Read the Form 483 →
Aurorium LLCInspection ended Mar 6, 2026 · FEI 1628757 · Observation 1
OBSERVATION 1 Failure to properly maintain buildings, facilities and equipment used in the manufacture of active pharmaceutical ingredients (API). Specifically, a) During our walk-through of the manufacturing facility on March 2 and 3, 2026, we noted there were areas of the building that had excessive corrosion, water leaking from equipment, and deterioration of walls and floors. Examples include the following. + We observed water leaking from a …
Contains “water leak*”Read the Form 483 →
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 1
… was initiated on 08/18/2025 to address overdue maintenance work orders, including overdue schedules for (b)(4), and (b)(4) preventive maintenance (PM) for HVAC equipment PM work orders; (b)(4) system ((b)(4) in Suite (b)(4) and Suite (b)(4) refrigerators, freezers, incubators, and stability chambers in micro and analytical labs; and BSCs and fume hoods in QC micro/sterility and production rooms. CAPA-00222 remains open without justification and …
Contains “HVAC”Read the Form 483 →
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 2
… (b)(4) and Suite (b)(4) could not be made because your firm placed black plastic sheets on the interior walls, preventing evaluation of the (b)(4) walls' state of repair, presence of scratches, and air flow assessment at the (b)(4). C. Your firm lacks post-batch cleaning procedures to prevent contamination. SOP-00098 ("Cleaning Procedure: (b)(4) ISO 5 (b)(4)," v2, effective 04/11/2025) requires only (b)(4) cleaning of the (b)(4) (ISO 5) and …
Contains “state of repair”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.42Design and construction featuresIn this theme's rule60
- 21 CFR 211.58MaintenanceIn this theme's rule8
- 21 CFR 211.22Responsibilities of quality control unit4
- 21 CFR 211.113Control of microbiological contamination4
- 21 CFR 211.192Production record review4
- 21 CFR 211.44LightingIn this theme's rule1
- 21 CFR 211.52Washing and toilet facilitiesIn this theme's rule1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.63Equipment design, size, and location1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1
Ask FDAgent about facilities and HVAC in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.